Description
TeSys Deca contactor, 3 poles (3NO), for switching 3-phase capacitor banks up to 63kVAR@400V 50Hz (104kVAR@690V). It provides a 220V 50/60Hz AC coil, 1NO+2NC instantaneous auxiliary contacts, with front mounted early make poles and pre-wired damping resistors for current limitation. For operating rates until 240 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA) and compliant with shunt capacitors standard IEC 60831, Green Premium product (RoHS/REACh).
Overview
| Product Name | CONTACTOR CAPACITOR SWITCHING |
|---|---|
| Tax Class | GST-18 |
| Coil Voltage | 220V AC |
| Number of Poles | 3P |
| Short Description | Capacitor contactor, TeSys D, 63 kVAR at 400 V/50 Hz, coil 220 V AC 50/60 Hz |
| Range | TESYS |
| Product name | TESYS LC1D.KTESYS DECA |
| Product or component type | CAPACITOR DUTY CONTACTOR |
| Device short name | LC1DWK |
| Device application | CONTROL |
| Contactor application | POWER FACTOR CORRECTION |
| Utilisation category | AC-6B |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | POWER CIRCUIT: 690 V AC 50/60 HZ |
| Reactive power rating | 35 KVAR AT 230 V AC 50 HZ 60 °C63 KVAR AT 400 V AC 50 HZ 60 °C67 KVAR AT 440 V AC 50 HZ 60 °C104 KVAR AT 690 V AC 50 HZ 60 °C30 KVAR AT 230 V AC 60 HZ 60 °C60 KVAR AT 460 V AC 60 HZ 60 °C80 KVAR AT 575 V AC 60 HZ 60 °C |
| Control circuit type | AC AT 50/60 HZ |
| [Uc] control circuit voltage | 220 V AC 50/60 HZ |
| Auxiliary contact composition | 1 NO + 2 NC INSTANTANEOUS |
| Electrical durability | 300000 CYCLES AT UE 400 V200000 CYCLES AT UE 690 V |
| Mounting support | DIN RAILPLATE |
| Standards | EN/IEC 60947-1EN/IEC 60947-4-1UL 60947-4-1CSA C22.2 NO 60947-4-1 |
| Product certifications | IECEE CB SchemeULCSAUKCA |
| Connections - terminals | CONTROL CIRCUIT: SCREW CLAMP TERMINALS 1 1…4 MM² - CABLE STIFFNESS: SOLIDCONTROL CIRCUIT: SCREW CLAMP TERMINALS 2 1…4 MM² - CABLE STIFFNESS: SOLIDCONTROL CIRCUIT: SCREW CLAMP TERMINALS 1 1…4 MM² - CABLE STIFFNESS: FLEXIBLE WITHOUT CABLE ENDCONTROL CIRCUIT: SCREW CLAMP TERMINALS 2 1…4 MM² - CABLE STIFFNESS: FLEXIBLE WITHOUT CABLE ENDCONTROL CIRCUIT: SCREW CLAMP TERMINALS 1 1…4 MM² - CABLE STIFFNESS: FLEXIBLE WITH CABLE ENDCONTROL CIRCUIT: SCREW CLAMP TERMINALS 2 1…2.5 MM² - CABLE STIFFNESS: FLEXIBLE WITH CABLE ENDPOWER CIRCUIT: CONNECTOR 1 4…50 MM² - CABLE STIFFNESS: SOLIDPOWER CIRCUIT: CONNECTOR 2 4…25 MM² - CABLE STIFFNESS: SOLIDPOWER CIRCUIT: CONNECTOR 1 4…50 MM² - CABLE STIFFNESS: FLEXIBLE WITHOUT CABLE ENDPOWER CIRCUIT: CONNECTOR 2 4…25 MM² - CABLE STIFFNESS: FLEXIBLE WITHOUT CABLE ENDPOWER CIRCUIT: CONNECTOR 1 4…50 MM² - CABLE STIFFNESS: FLEXIBLE WITH CABLE ENDPOWER CIRCUIT: CONNECTOR 2 4…16 MM² - CABLE STIFFNESS: FLEXIBLE WITH CABLE END |
| Tightening torque | POWER CIRCUIT: 9 N.M - ON CONNECTORCONTROL CIRCUIT: 1.7 N.M - ON SCREW CLAMP TERMINALS |
| Maximum operating rate | 100 CYC/H |
| Auxiliary contacts type | TYPE MECHANICALLY LINKED 1 NO + 2 NC CONFORMING TO IEC 60947-5-1 |
| IP degree of protection | IP20 FRONT FACE CONFORMING TO IEC 60529 |
| Ambient air temperature for operation | -5…60 °C |
| Ambient air temperature for storage | -60…80 °C |
| Operating altitude | 0...3000 M |
| Height | 180 MM |
| Width | 85 MM |
| Depth | 154 MM |
| Product weight | 1.65 KG |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 19.000 CM |
| Package 1 Width | 13.200 CM |
| Package 1 Length | 17.000 CM |
| Package 1 Weight | 1.786 KG |
| Unit Type of Package 2 | S06 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 75.000 CM |
| Package 2 Width | 60.000 CM |
| Package 2 Length | 80.000 CM |
| Package 2 Weight | 95.368 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| REACh free of SVHC | ✓ |
| Toxic heavy metal free | ✓ |
| Mercury free | ✓ |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | No need of specific recycling operations |
| Recyclability potential, in % | 67 |
| Total lifecycle Carbon footprint | 97 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 10.946 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 11 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.52233 |
| Carbon footprint of the distribution phase [A4] | 0.5 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.29663 |
| Carbon footprint of the installation phase [A5] | 0.3 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 80.77 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 81 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 4.7072 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 5 kg CO2 eq. |
| REACh Regulation | Free of Substances of Very High Concern above the threshold (Download) |
| EU RoHS Directive | Compliant (Download) |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Reviews
Description
TeSys Deca contactor, 3 poles (3NO), for switching 3-phase capacitor banks up to 63kVAR@400V 50Hz (104kVAR@690V). It provides a 220V 50/60Hz AC coil, 1NO+2NC instantaneous auxiliary contacts, with front mounted early make poles and pre-wired damping resistors for current limitation. For operating rates until 240 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA) and compliant with shunt capacitors standard IEC 60831, Green Premium product (RoHS/REACh).
Overview
| Product Name | CONTACTOR CAPACITOR SWITCHING |
|---|---|
| Tax Class | GST-18 |
| Coil Voltage | 220V AC |
| Number of Poles | 3P |
| Short Description | Capacitor contactor, TeSys D, 63 kVAR at 400 V/50 Hz, coil 220 V AC 50/60 Hz |
| Range | TESYS |
| Product name | TESYS LC1D.KTESYS DECA |
| Product or component type | CAPACITOR DUTY CONTACTOR |
| Device short name | LC1DWK |
| Device application | CONTROL |
| Contactor application | POWER FACTOR CORRECTION |
| Utilisation category | AC-6B |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | POWER CIRCUIT: 690 V AC 50/60 HZ |
| Reactive power rating | 35 KVAR AT 230 V AC 50 HZ 60 °C63 KVAR AT 400 V AC 50 HZ 60 °C67 KVAR AT 440 V AC 50 HZ 60 °C104 KVAR AT 690 V AC 50 HZ 60 °C30 KVAR AT 230 V AC 60 HZ 60 °C60 KVAR AT 460 V AC 60 HZ 60 °C80 KVAR AT 575 V AC 60 HZ 60 °C |
| Control circuit type | AC AT 50/60 HZ |
| [Uc] control circuit voltage | 220 V AC 50/60 HZ |
| Auxiliary contact composition | 1 NO + 2 NC INSTANTANEOUS |
| Electrical durability | 300000 CYCLES AT UE 400 V200000 CYCLES AT UE 690 V |
| Mounting support | DIN RAILPLATE |
| Standards | EN/IEC 60947-1EN/IEC 60947-4-1UL 60947-4-1CSA C22.2 NO 60947-4-1 |
| Product certifications | IECEE CB SchemeULCSAUKCA |
| Connections - terminals | CONTROL CIRCUIT: SCREW CLAMP TERMINALS 1 1…4 MM² - CABLE STIFFNESS: SOLIDCONTROL CIRCUIT: SCREW CLAMP TERMINALS 2 1…4 MM² - CABLE STIFFNESS: SOLIDCONTROL CIRCUIT: SCREW CLAMP TERMINALS 1 1…4 MM² - CABLE STIFFNESS: FLEXIBLE WITHOUT CABLE ENDCONTROL CIRCUIT: SCREW CLAMP TERMINALS 2 1…4 MM² - CABLE STIFFNESS: FLEXIBLE WITHOUT CABLE ENDCONTROL CIRCUIT: SCREW CLAMP TERMINALS 1 1…4 MM² - CABLE STIFFNESS: FLEXIBLE WITH CABLE ENDCONTROL CIRCUIT: SCREW CLAMP TERMINALS 2 1…2.5 MM² - CABLE STIFFNESS: FLEXIBLE WITH CABLE ENDPOWER CIRCUIT: CONNECTOR 1 4…50 MM² - CABLE STIFFNESS: SOLIDPOWER CIRCUIT: CONNECTOR 2 4…25 MM² - CABLE STIFFNESS: SOLIDPOWER CIRCUIT: CONNECTOR 1 4…50 MM² - CABLE STIFFNESS: FLEXIBLE WITHOUT CABLE ENDPOWER CIRCUIT: CONNECTOR 2 4…25 MM² - CABLE STIFFNESS: FLEXIBLE WITHOUT CABLE ENDPOWER CIRCUIT: CONNECTOR 1 4…50 MM² - CABLE STIFFNESS: FLEXIBLE WITH CABLE ENDPOWER CIRCUIT: CONNECTOR 2 4…16 MM² - CABLE STIFFNESS: FLEXIBLE WITH CABLE END |
| Tightening torque | POWER CIRCUIT: 9 N.M - ON CONNECTORCONTROL CIRCUIT: 1.7 N.M - ON SCREW CLAMP TERMINALS |
| Maximum operating rate | 100 CYC/H |
| Auxiliary contacts type | TYPE MECHANICALLY LINKED 1 NO + 2 NC CONFORMING TO IEC 60947-5-1 |
| IP degree of protection | IP20 FRONT FACE CONFORMING TO IEC 60529 |
| Ambient air temperature for operation | -5…60 °C |
| Ambient air temperature for storage | -60…80 °C |
| Operating altitude | 0...3000 M |
| Height | 180 MM |
| Width | 85 MM |
| Depth | 154 MM |
| Product weight | 1.65 KG |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 19.000 CM |
| Package 1 Width | 13.200 CM |
| Package 1 Length | 17.000 CM |
| Package 1 Weight | 1.786 KG |
| Unit Type of Package 2 | S06 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 75.000 CM |
| Package 2 Width | 60.000 CM |
| Package 2 Length | 80.000 CM |
| Package 2 Weight | 95.368 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| REACh free of SVHC | ✓ |
| Toxic heavy metal free | ✓ |
| Mercury free | ✓ |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | No need of specific recycling operations |
| Recyclability potential, in % | 67 |
| Total lifecycle Carbon footprint | 97 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 10.946 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 11 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.52233 |
| Carbon footprint of the distribution phase [A4] | 0.5 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.29663 |
| Carbon footprint of the installation phase [A5] | 0.3 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 80.77 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 81 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 4.7072 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 5 kg CO2 eq. |
| REACh Regulation | Free of Substances of Very High Concern above the threshold (Download) |
| EU RoHS Directive | Compliant (Download) |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |