residual current circuit breaker ID - 4 poles - 125 A - class A 30 mA

16924
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Product Details

Activity HDCFD
Pincode Group default
Part Number 16924
[Uimp] rated impulse withstand voltage 4 kV conforming to IEC 61008-1
9 Mm Pitches 8
Connection Pitch 18 mm between phases
Device Location in System outgoer
Earth-leakage Protection Class type A
Earth-leakage Protection Time Delay instantaneous
Earth-leakage Sensitivity 30 mA
Neutral Position left
Provision for Padlocking padlockable
Rated Breaking and Making Capacity Im = 1250 A 400 V conforming to IEC 61008
Rated Conditional Short-circuit Current Inc 10 kA 125 A
Residual Current Tripping Technology electromechanical
Tropicalisation 2 conforming to IEC 61008
ambient air temperature for storage -40-85 °C
colour grey
compatibility code ID_RCCB
connections - terminals tunnel type terminals2 cable(s) 1.5-16 mm² flexible, tunnel type terminals2 cable(s) 1.5-16 mm² rigid, tunnel type terminals1 cable(s) 1.5-50 mm² rigid, tunnel type terminals1 cable(s) 1.5-35 mm² flexible, tunnel type terminals1 cable(s) 1.5-35 mm² flexible with ferrule, tunnel type terminals2 cable(s) 1.5-16 mm² flexible with ferrule
control type toggle
depth 76 mm
device short name RCCB-ID
Electrical Durability 2000 cycles
height 86 mm
IP degree of protection IP20 conforming to IEC 60529, IP40 (modular enclosure) conforming to IEC 60529
Market Segment small commercial
mechanical durability 5000 cycles
mounting mode fixed
mounting support 35 mm symmetrical DIN rail
net weight 420 g
network frequency 50/60 Hz
network type AC
operating altitude 2000 m
Poles Description 4P
pollution degree 3
product or component type residual current circuit breaker (RCCB)
range Acti9
range of product ID RCCB
relative humidity 95-95 % at 55-55 °C
width 72 mm
Wire Stripping Length 11 mm
ambient air temperature for operation -25-40 °C
standards IEC 60947-3, IEC 60947-1, IEC 61008
[Ui] rated insulation voltage 440 V AC 50 Hz conforming to IEC 61008-1
tightening torque 3-3 N.m

Seller Information

Documents

Reviews

Write Your Own Review
You're reviewing: residual current circuit breaker ID - 4 poles - 125 A - class A 30 mA
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.

Frequently Bought Together

impulse relay iTL - 1P - 1NO - 16A - coil 110 VDC - 230...240 VAC 50/60Hz
A9C30811

In stock

AED 33.00
AED 49.80
Acti 9 - comb busbar - 1L+N - 18 mm pitch - 12 modules - 100 A
A9XPH212

In stock

AED 51.00
AED 76.81
distribution connectors for 3 cables - set of 4
19091

In stock

AED 98.00
AED 192.60
iCT 25A 2NO 230...240V 50Hz contactor
A9C20732

In stock

AED 54.00
AED 81.03
distribution connectors for 3 cables - set of 3
19096

In stock

AED 66.79
AED 109.55
auxiliary contact - 1 NC + 1 OC - 380..415 V - 6 A - for RCCB
16940

In stock

AED 106.00
AED 159.31