TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 125 A 48 V AC 50/60 Hz coil

LC1D80008E7
Be the first one to review this.

Excl. Tax

login_green To View the best prices please Sign in / Register.
loader
Loading...
loader
Loading...

Product Selection Summary

Description

TeSys Deca Advanced Contactors

Stay smart with the world's best-selling motor control solutions from the inventor of the world's first contactor Schneider Electric. For almost a century, TeSys motor controls have driven the industry with innovations in motor protection, monitoring, and control.

Fewer Parts, More Power

TeSys Deca Advanced contactors simplify your maintenance services with 90% less references needed. Associated with TeSys Deca electronic overload relays, reduces heat generation and energy consumption by up to 50%.

Simple to install

TeSys Deca Advanced contactors offer quick simple setup, while maintaining a compact size and suitable for safety applications thanks to mechanically linked contacts and mirror contacts

Efficiency maintenance

High-performance solutions with up to 20 In breaking capacity, multistandard compliance, and direct PLC connectivity for seamless integration.

Enhance your power solutions with our extensive range of accessories

Auxiliary Contact Blocks

Interface module

Suppressor Module

Gain peace of mind, quality, and value for your installations

Versatile power for every application

TeSys Deca contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This IEC contactor can be mounted on DIN rail or mounted directly to a panel.

Cost and space saving

Lorem Ipsum is simply dummy text of the printing and 

Reliable

Lorem Ipsum is simply dummy text of the printing and 

Robust

Lorem Ipsum is simply dummy text of the printing and 

Product Details

Activity PPCTR
Part Number LC1D80008E7
[Ith] conventional free air thermal current 125 A (at 60 °C) for power circuit
[Uc] control circuit voltage 48 V AC 50/60 Hz
[Ui] rated insulation voltage power circuit: 600 V CSA certified, power circuit: 600 V UL certified, power circuit: 1000 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
associated fuse rating 200 A gG at <= 690 V coordination type 1 for power circuit, 160 A gG at <= 690 V coordination type 2 for power circuit
average impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
climatic withstand conforming to IACS E10 exposure to damp heat
coil technology without built-in suppressor module
compatibility code LC1D
connections - terminals control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 4-50 mm² - cable stiffness: solid without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: solid without cable end
contact compatibility M1
contactor application resistive load
control circuit type AC at 50/60 Hz
control circuit voltage limits 0.85...1.1 Uc (-40-55 °C):operational AC 60 Hz, 0.3...0.6 Uc (-40-55 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-55 °C):operational AC 50 Hz
Depth 140 mm
device short name LC1D
fire resistance 850 °C conforming to IEC 60695-2-1
flame retardance V1 conforming to UL 94
heat dissipation 6-10 W at 50/60 Hz
Height 127 mm
hold-in power consumption in VA 26-26 VA 60 Hz cos phi 0.3 (at 20 °C), 26-26 VA 50 Hz cos phi 0.3 (at 20 °C)
inrush power in VA 245-245 VA 60 Hz cos phi 0.75 (at 20 °C), 245-245 VA 50 Hz cos phi 0.75 (at 20 °C)
IP degree of protection IP20 front face conforming to IEC 60529
Irms rated making capacity 1100 A at 440 V for power circuit conforming to IEC 60947
maximum operating rate 3600 cyc/h 60 °C
mechanical durability 4 Mcycles
mounting support plate, rail
net weight 1.84 kg
operating altitude 0...3000 m
operating time 20...35 ms closing, 6...20 ms opening
overvoltage category III
permissible ambient air temperature around the device -40-60 °C, 60-70 °C with derating
pole contact composition 2 NO + 2 NC
Poles Description 4P
pollution degree 3
power dissipation per pole 12.5 W AC-1
product certifications UL, CSA, CCC, EAC, UKCA, CB, EU-RO-MR by DNV-GL
product or component type contactor
protective cover without
protective treatment TH conforming to IEC 60068-2-30
Range TeSys
range of product TeSys Deca
rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
rated operational voltage limits power circuit: <= 690 V AC 25...400 Hz
safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
tightening torque control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2, power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm, power circuit: 12 N.m - on connector hexagonal screw head 4 mm, control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
utilisation category AC-1
width 96 mm
[Icw] rated short-time withstand current 640 A 40 °C - 10 s for power circuit, 990 A 40 °C - 1 s for power circuit, 135 A 40 °C - 10 min for power circuit, 320 A 40 °C - 1 min for power circuit
standards EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, GB/T 14048.4
[Ie] rated operational current 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
mechanical robustness vibrations contactor open (2 Gn, 5...300 Hz) , shocks contactor open (8 Gn for 11 ms) , vibrations contactor closed (3 Gn, 5...300 Hz) , shocks contactor closed (10 Gn for 11 ms)
Electrical Durability 0.8 Mcycles 125 A AC-1 at Ue <= 440 V

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Frequently Bought Together

LADN22 Auxiliary contact block, TeSys D, 2NO + 2NC, front mounting, screw terminals.
LADN22

check-small In stock

Auxiliary contact block, TeSys D, 1NO + 1NC, front mounting, screw terminals
LADN11

check-small In stock

Auxiliary contact block, TeSys D, 2NO, front mounting, screw clamp terminals
LADN20

check-small In stock

Time delay auxiliary contact block, TeSys D, 1NO + 1NC, on delay 0.1-30s, front, screw clamp terminals
LADT2

check-small In stock

Auxiliary contact block, TeSys D, 3NO + 1NC, front mounting, screw clamp terminals
LADN31

check-small In stock

Auxiliary contact block, TeSys D, 4NO, front mounting, screw clamp terminals
LADN40

check-small In stock

Time delay auxiliary contact block, TeSys D, 1NO + 1NC, off delay 1-30s, front, screw clamp terminals
LADR2

check-small In stock

Time delay auxiliary contact block, TeSys D, 1NO + 1NC, on delay 10-180s, front, screw clamp terminals
LADT4

check-small In stock