controller M221 40 IO relay Ethernet

TM221CE40R
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Product Details

Activity IDMST
Resistance to electrostatic discharge 8 kV in air conforming to EN/IEC 61000-4-2, 4 kV on contact conforming to EN/IEC 61000-4-2
Pincode Group default
Part Number TM221CE40R
ambient air temperature for storage -25-70 °C
depth 70 mm
supply voltage limits 85-264 V
width 160 mm
Discrete output current 2:00 AM
Supply (serial)serial link supply: 5 V, <200 mA
Data backed up 256 kB built-in flash memory for backup of application and data
Data storage equipment 2 GB SD card (optional)
Reset time 1 s
Clock drift <= 30 s/month at 25-25 °C
Immunity to microbreaks 10 ms
Discrete input current 7 mA for discrete input, 5 mA for fast input
Voltage state 1 guaranteed >= 15 V for input
Discrete input voltage 24 V
Backup time 1 year at 25 °C (by interruption of power supply)
Voltage state 0 guaranteed <= 5 V for input
Discrete input number 24 , discrete input conforming to IEC 61131-2 Type 1
Resistance to electromagnetic fields 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3, 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3, 1 V/m 2...2.7 GHz conforming to EN/IEC 61000-4-3
Surge withstand 2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5, 2 kV relay output common mode conforming to EN/IEC 61000-4-5, 1 kV I/O common mode conforming to EN/IEC 61000-4-5, 1 kV shielded cable common mode conforming to EN/IEC 61000-4-5, 0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5, 1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5, 1 kV relay output differential mode conforming to EN/IEC 61000-4-5, 0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
Resistance to fast transients 2 kV (power lines) conforming to EN/IEC 61000-4-4, 2 kV (relay output) conforming to EN/IEC 61000-4-4, 1 kV (I/O) conforming to EN/IEC 61000-4-4, 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4, 1 kV (serial link) conforming to EN/IEC 61000-4-4
Electromagnetic emission conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15-0.5 MHz conforming to EN/IEC 55011, conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5-300 MHz conforming to EN/IEC 55011, conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10-150 kHz conforming to EN/IEC 55011, conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5-30 MHz conforming to EN/IEC 55011, radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30-230 MHz conforming to EN/IEC 55011, conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150-1500 kHz conforming to EN/IEC 55011, radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200-1000 MHz conforming to EN/IEC 55011
Analogue input resolution 10 bits
Analogue input number 2 at 0...10 V
Permitted overload on inputs +/- 30 V DC for 5 min (maximum) for analog input, +/- 13 V DC (permanent) for analog input
Discrete output type relay normally open
LSB value 10 mV
Conversion time 1 ms per channel + 1 controller cycle time for analogue input analog input
Discrete output number 16 relay
Sensor power supply 24-24 V DC at 250 mA supplied by the controller
Realtime clock with
Discrete input logic sink or source (positive/negative)
Discrete input voltage type DC
Maximum number of I/O expansion module 7 for relay output
Counting input number 4 fast input (HSC mode) at 100 kHz 32 bits
Resistance to conducted disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6, 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL), 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Maximum cable distance between devices shielded cable: <10 m for fast input, unshielded cable: <30 m for output, unshielded cable: <30 m for digital input, unshielded cable: <1 m for analog input
Maximum current per output common 7:00 AM
Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15-15 m for RS485, 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3-3 m for RS232, 480 Mbit/s for USB
Discrete I/O number 40
Configurable filtering time 0 ms for input, 3 ms for input, 12 ms for input
Discrete output voltage 5...125 V DC, 5...250 V AC
Memory capacity 256 kB for user application and data RAM with 10000 instructions, 256 kB for internal variables RAM
Execution time for 1 KInstruction 0.3 ms for event and periodic task
Absolute accuracy error +/- 1 % of full scale for analog input
Resistance to magnetic fields 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
Port Ethernet 10BASE-T/100BASE-TX 1 port with 100 m copper cable
Maximum power consumption in VA 70 VA at 100...240 V with max number of I/O expansion module, 41 VA at 100...240 V without I/O expansion module
Regulation loop adjustable PID regulator up to 14 simultaneous loops
Communication service DHCP client, Modbus TCP client, Ethernet/IP adapter, Modbus TCP server, Modbus TCP slave device
Exct time for event task 60 µs response time
Execution time per instruction 0.2 µs Boolean
Maximum size of object areas 8000 %MW memory words, 255 %TM timers, 512 %KW constant words, 255 %C counters, 512 %M memory bits
Minimum load 1 mA at 5 V DC for relay output
vibration resistance 3.5 mm at 5-8.4 Hz on symmetrical rail, 3.5 mm at 5-8.4 Hz on panel mounting, 1 gn at 8.4-150 Hz on symmetrical rail, 1 gn at 8.4-150 Hz on panel mounting
ambient air temperature for operation -10-55 °C (horizontal installation), -10-35 °C (vertical installation)
standards EN/IEC 60664-1, EN/IEC 61131-2, EN/IEC 61010-2-201
Storage Altitude 0-3000 m
Communication Port Protocol USB port: USB - SoMachine-Network, non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network, Ethernet
Control Signal Type single phase, A/B, pulse/direction
Switching Frequency 20 switching operations/minute with maximum load
Electrical Durability 100000 cycles AC-12, 120 V, 240 VA, resistive, 100000 cycles AC-14, cos phi = 0.7 , 240 V, 240 VA, inductive, 300000 cycles AC-14, cos phi = 0.7 , 120 V, 36 VA, inductive, 300000 cycles AC-14, cos phi = 0.7 , 240 V, 72 VA, inductive, 100000 cycles DC-12, 24 V, 48 W, resistive, 300000 cycles DC-12, 24 V, 16 W, resistive, 100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms), 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms), 100000 cycles AC-12, 240 V, 480 VA, resistive, 300000 cycles AC-12, 120 V, 80 VA, resistive, 300000 cycles AC-12, 240 V, 160 VA, resistive, 100000 cycles AC-15, cos phi = 0.35 , 120 V, 60 VA, inductive, 100000 cycles AC-15, cos phi = 0.35 , 240 V, 120 VA, inductive, 300000 cycles AC-15, cos phi = 0.35 , 120 V, 18 VA, inductive, 300000 cycles AC-15, cos phi = 0.35 , 240 V, 36 VA, inductive, 100000 cycles AC-14, cos phi = 0.7 , 120 V, 120 VA, inductive

Seller Information

Documents

Reviews

Write Your Own Review
You're reviewing: controller M221 40 IO relay Ethernet
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.

Frequently Bought Together

graphic display unit - 240 x 160 pixels
TMH2GDB

In stock

cartridge M221 - 2 analog voltage outputs - I/O extension
TMC2AQ2V

In stock

cartridge M221 - 1 serial line - communication extension
TMC2SL1

In stock