Activity |
PPCTR |
Part Number |
LC1D18P7 |
Weight |
353.0 g |
Package1 Length*Width*Height |
11.0 cm x 9.0 cm x 5.0 cm |
Country of Manufacturing |
France |
[Ie] rated operational current |
18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
[Ith] conventional free air thermal current |
10 A (at 60 °C) for signalling circuit, 32 A (at 60 °C) for power circuit |
[Uc] control circuit voltage |
230 V AC 50/60 Hz |
[ue] Rated Operational Voltage |
power circuit: <= 690 V AC 25...400 Hz, power circuit: <= 300 V DC |
[Ui] rated insulation voltage |
power circuit: 690 V conforming to IEC 60947-4-1, power circuit: 600 V CSA certified, power circuit: 600 V UL certified, signalling circuit: 690 V conforming to IEC 60947-1, signalling circuit: 600 V CSA certified, signalling circuit: 600 V UL certified |
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947 |
ambient air temperature for operation |
-40-60 °C, 60-70 °C with derating |
ambient air temperature for storage |
-60-80 °C |
associated fuse rating |
10 A gG for signalling circuit conforming to IEC 60947-5-1, 50 A gG at <= 690 V coordination type 1 for power circuit, 35 A gG at <= 690 V coordination type 2 for power circuit |
auxiliary contact composition |
1 NO + 1 NC |
auxiliary contacts type |
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1 |
average impedance |
2.5 mOhm - Ith 32 A 50 Hz for power circuit |
climatic withstand |
conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
coil technology |
without built-in suppressor module |
compatibility code |
LC1D |
connections - terminals |
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 1.5-6 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-6 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1.5-6 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: solid without cable end |
contact compatibility |
M2 |
contactor application |
motor control, resistive load |
contactor coil voltage |
230 V AC standard |
control circuit type |
AC at 50/60 Hz standard |
control circuit voltage limits |
0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz |
depth |
86 mm |
device short name |
LC1D |
electrical durability |
1.65 Mcycles 18 A AC-3 at Ue <= 440 V, 1 Mcycles 32 A AC-1 at Ue <= 440 V, 1.65 Mcycles 18 A AC-3e at Ue <= 440 V |
fire resistance |
850 °C conforming to IEC 60695-2-1 |
flame retardance |
V1 conforming to UL 94 |
heat dissipation |
2-3 W at 50/60 Hz |
height |
77 mm |
hold-in power consumption in VA |
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C), 7-7 VA 50 Hz cos phi 0.3 (at 20 °C) |
inrush power in VA |
70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C) |
insulation resistance |
> 10 MOhm for signalling circuit |
IP degree of protection |
IP20 front face conforming to IEC 60529 |
Irms rated making capacity |
140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 300 A at 440 V for power circuit conforming to IEC 60947 |
maximum operating rate |
3600 cyc/h 60 °C |
mechanical durability |
15 Mcycles |
mechanical robustness |
vibrations contactor open: 2 Gn, 5...300 Hz, vibrations contactor closed: 4 Gn, 5...300 Hz, shocks contactor open: 10 Gn for 11 ms, shocks contactor closed: 15 Gn for 11 ms |
minimum switching current |
5 mA for signalling circuit |
minimum switching voltage |
17 V for signalling circuit |
motor power hp |
1 hp at 115 V AC 50/60 Hz for 1 phase motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors, 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
motor power kW |
4 kW at 220...230 V AC 50/60 Hz (AC-3), 7.5 kW at 380...400 V AC 50/60 Hz (AC-3), 9 kW at 415...440 V AC 50/60 Hz (AC-3), 10 kW at 500 V AC 50/60 Hz (AC-3), 10 kW at 660...690 V AC 50/60 Hz (AC-3), 4 kW at 400 V AC 50/60 Hz (AC-4), 4 kW at 220...230 V AC 50/60 Hz (AC-3e), 7.5 kW at 380...400 V AC 50/60 Hz (AC-3e), 9 kW at 415...440 V AC 50/60 Hz (AC-3e), 10 kW at 500 V AC 50/60 Hz (AC-3e), 10 kW at 660...690 V AC 50/60 Hz (AC-3e) |
motor starter type |
direct on-line contactor |
mounting support |
rail, plate |
net weight |
0.33 kg |
non-overlap time |
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
operating altitude |
0...3000 m |
operating time |
12...22 ms closing, 4...19 ms opening |
overvoltage category |
III |
permissible ambient air temperature around the device |
-40-60 °C, 60-70 °C with derating |
pole contact composition |
3 NO |
Poles Description |
3P |
pollution degree |
3 |
power dissipation per pole |
2.5 W AC-1, 0.8 W AC-3, 0.8 W AC-3e |
power range |
4-6 kW at 200-240 V 3 phases, 7-11 kW at 380-440 V 3 phases, 7-11 kW at 480-500 V 3 phases |
product certifications |
UL, LROS (Lloyds register of shipping), BV, CSA, GOST, GL, CCC, DNV, RINA, UKCA |
product or component type |
contactor |
protective cover |
with |
protective treatment |
TH conforming to IEC 60068-2-30 |
range |
TeSys, TeSys Deca |
range of product |
TeSys Deca |
rated breaking capacity |
300 A at 440 V for power circuit conforming to IEC 60947 |
rated operational voltage limits |
power circuit: <= 690 V AC 25...400 Hz, power circuit: <= 300 V DC |
safety reliability level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
signalling circuit frequency |
25...400 Hz |
standards |
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1 |
tightening torque |
power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2, control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2, control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2, power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
utilisation category |
AC-3, AC-1, AC-4, AC-3e |
width |
45 mm |
[Icw] rated short-time withstand current |
145 A 40 °C - 10 s for power circuit, 240 A 40 °C - 1 s for power circuit, 40 A 40 °C - 10 min for power circuit, 84 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
standards |
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1 |
[Ie] rated operational current |
18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
insulation resistance |
> 10 MOhm for signalling circuit |
mechanical robustness |
vibrations contactor open (2 Gn, 5...300 Hz) , vibrations contactor closed (4 Gn, 5...300 Hz) , shocks contactor open (10 Gn for 11 ms) , shocks contactor closed (15 Gn for 11 ms) |
Electrical Durability |
1.65 Mcycles 18 A AC-3 at Ue <= 440 V, 1 Mcycles 32 A AC-1 at Ue <= 440 V, 1.65 Mcycles 18 A AC-3e at Ue <= 440 V |