switch-disconnector Compact INS250 - 250 A - 3 poles
SKU :
31106
calcPageSize())"
/>
calcActive())">
Loading...
No sellers found for this product.
AEDÂ 1,032.50
AEDÂ 658.00
Excl. Tax
To View the best prices please Sign in / Register.
Shipping:
Out of stock
switch-disconnector Compact INS250 - 250 A - 3 poles
AEDÂ 1,032.50
AEDÂ 658.00
- Specifications
- Reviews
Overview
| Activity | PPCCB |
|---|---|
| Part Number | 31106 |
| [icm] Rated Short-circuit Making Capacity | 30 kA switch-disconnector alone 690 V AC at 50/60 Hz, 330 kA with upstream protection circuit breaker 690 V AC at 50/60 Hz |
| [Icw] rated short-time withstand current | 1.8 kA during 30 s conforming to IEC 60947-3, 2.2 kA during 20 s conforming to IEC 60947-3, 4.9 kA during 3 s conforming to IEC 60947-3, 8.5 kA during 1 s conforming to IEC 60947-3 |
| Connection Pitch | 35 mm |
| Contact Position Indicator | yes |
| Downside Connection | front |
| suitability for isolation | yes |
| Upside Connection | front |
| ambient air temperature for storage | -50-85 °C |
| compatibility code | INS250 |
| control type | direct front rotary handle |
| Depth | 96 mm |
| device short name | Interpact INS250 |
| Electrical Durability | AC-22A: 1500 cycles 440 V AC 50/60 Hz, AC-22A: 1500 cycles 500 V AC 50/60 Hz, AC-22A: 1500 cycles 690 V AC 50/60 Hz, AC-23A: 1500 cycles 440 V AC 50/60 Hz, AC-23A: 1500 cycles 500 V AC 50/60 Hz, AC-23A: 1500 cycles 690 V AC 50/60 Hz, DC-22A: 1500 cycles 125 V DC 2 poles in series, DC-23A: 1500 cycles 125 V DC 2 poles in series |
| Height | 136 mm |
| IK degree of protection | IK07 conforming to EN 50102 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| mechanical durability | 15000 cycles |
| mounting mode | fixed |
| mounting support | rail, plate |
| net weight | 2 kg |
| network frequency | 50/60 Hz |
| network type | DC, AC |
| Poles Description | 3P |
| pollution degree | 3 |
| product certifications | KEMA-KEUR, CCC |
| product or component type | switch disconnector |
| Range | ComPact |
| range of product | INS250 |
| width | 140 mm |
| Visible break | no |
| Handle colour | black |
| Switch-disconnector name | Interpact INS250 |
| ambient air temperature for operation | -25-70 °C |
| standards | IEC 60947-3, IEC 60947-1 |
| [Ie] rated operational current | AC-22A: 250 A AC 50/60 Hz 220/240 V, AC-22A: 250 A AC 50/60 Hz 380/415 V, AC-22A: 250 A AC 50/60 Hz 440/480 V, AC-22A: 250 A AC 50/60 Hz 480 V NEMA, AC-22A: 250 A AC 50/60 Hz 500/525 V, AC-22A: 250 A AC 50/60 Hz 660/690 V, AC-23A: 250 A AC 50/60 Hz 220/240 V, AC-23A: 250 A AC 50/60 Hz 380/415 V, AC-23A: 250 A AC 50/60 Hz 440/480 V, AC-23A: 250 A AC 50/60 Hz 480 V NEMA, AC-23A: 250 A AC 50/60 Hz 500/525 V, AC-23A: 250 A AC 50/60 Hz 660/690 V, DC-22A: 250 A DC 125 V 2 poles in series, DC-23A: 250 A DC 125 V 2 poles in series |
| Maximum Power | AC-23: 132 kW at 380/415 V AC 50/60 Hz, AC-23: 150 kW at 440 V AC 50/60 Hz, AC-23: 150 kW at 480 V AC 50/60 Hz (NEMA), AC-23: 160 kW at 500/525 V AC 50/60 Hz, AC-23: 210 kW at 660/690 V AC 50/60 Hz, AC-23: 75 kW at 220/240 V AC 50/60 Hz, AC-23: 75 kW at 230 V AC 50/60 Hz (NEMA) |
| [Ith] conventional free air thermal current | 250 A at 60 °C |
| [Ui] rated insulation voltage | 750 V AC 50/60 Hz |
Reviews
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Overview
| Activity | PPCCB |
|---|---|
| Part Number | 31106 |
| [icm] Rated Short-circuit Making Capacity | 30 kA switch-disconnector alone 690 V AC at 50/60 Hz, 330 kA with upstream protection circuit breaker 690 V AC at 50/60 Hz |
| [Icw] rated short-time withstand current | 1.8 kA during 30 s conforming to IEC 60947-3, 2.2 kA during 20 s conforming to IEC 60947-3, 4.9 kA during 3 s conforming to IEC 60947-3, 8.5 kA during 1 s conforming to IEC 60947-3 |
| Connection Pitch | 35 mm |
| Contact Position Indicator | yes |
| Downside Connection | front |
| suitability for isolation | yes |
| Upside Connection | front |
| ambient air temperature for storage | -50-85 °C |
| compatibility code | INS250 |
| control type | direct front rotary handle |
| Depth | 96 mm |
| device short name | Interpact INS250 |
| Electrical Durability | AC-22A: 1500 cycles 440 V AC 50/60 Hz, AC-22A: 1500 cycles 500 V AC 50/60 Hz, AC-22A: 1500 cycles 690 V AC 50/60 Hz, AC-23A: 1500 cycles 440 V AC 50/60 Hz, AC-23A: 1500 cycles 500 V AC 50/60 Hz, AC-23A: 1500 cycles 690 V AC 50/60 Hz, DC-22A: 1500 cycles 125 V DC 2 poles in series, DC-23A: 1500 cycles 125 V DC 2 poles in series |
| Height | 136 mm |
| IK degree of protection | IK07 conforming to EN 50102 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| mechanical durability | 15000 cycles |
| mounting mode | fixed |
| mounting support | rail, plate |
| net weight | 2 kg |
| network frequency | 50/60 Hz |
| network type | DC, AC |
| Poles Description | 3P |
| pollution degree | 3 |
| product certifications | KEMA-KEUR, CCC |
| product or component type | switch disconnector |
| Range | ComPact |
| range of product | INS250 |
| width | 140 mm |
| Visible break | no |
| Handle colour | black |
| Switch-disconnector name | Interpact INS250 |
| ambient air temperature for operation | -25-70 °C |
| standards | IEC 60947-3, IEC 60947-1 |
| [Ie] rated operational current | AC-22A: 250 A AC 50/60 Hz 220/240 V, AC-22A: 250 A AC 50/60 Hz 380/415 V, AC-22A: 250 A AC 50/60 Hz 440/480 V, AC-22A: 250 A AC 50/60 Hz 480 V NEMA, AC-22A: 250 A AC 50/60 Hz 500/525 V, AC-22A: 250 A AC 50/60 Hz 660/690 V, AC-23A: 250 A AC 50/60 Hz 220/240 V, AC-23A: 250 A AC 50/60 Hz 380/415 V, AC-23A: 250 A AC 50/60 Hz 440/480 V, AC-23A: 250 A AC 50/60 Hz 480 V NEMA, AC-23A: 250 A AC 50/60 Hz 500/525 V, AC-23A: 250 A AC 50/60 Hz 660/690 V, DC-22A: 250 A DC 125 V 2 poles in series, DC-23A: 250 A DC 125 V 2 poles in series |
| Maximum Power | AC-23: 132 kW at 380/415 V AC 50/60 Hz, AC-23: 150 kW at 440 V AC 50/60 Hz, AC-23: 150 kW at 480 V AC 50/60 Hz (NEMA), AC-23: 160 kW at 500/525 V AC 50/60 Hz, AC-23: 210 kW at 660/690 V AC 50/60 Hz, AC-23: 75 kW at 220/240 V AC 50/60 Hz, AC-23: 75 kW at 230 V AC 50/60 Hz (NEMA) |
| [Ith] conventional free air thermal current | 250 A at 60 °C |
| [Ui] rated insulation voltage | 750 V AC 50/60 Hz |