off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC

RE17RCMU
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Description

How to Video

Promotional Video

Product Details

Activity IDSIG
Pincode Group default
Part Number RE17RCMU
Rated current 5:00 AM
[Uc] control circuit voltage 24 V, 24...240 V
[Uimp] rated impulse withstand voltage 5 kV during 1.2/50 µs
[Us] rated supply voltage 24...240 V AC 50/60 Hz, 24 V DC
ambient air temperature for storage -30-60 °C
breaking capacity 2000 VA
compatibility code RE17
connections - terminals screw connectors
contacts material cadmium free
control type selector switch front panel
depth 72 mm
device short name RE17R
dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
height 90 mm
input voltage 10 V
IP degree of protection IP20 (terminal block) conforming to IEC 60529, IP40 (housing) conforming to IEC 60529, IP50 (front panel) conforming to IEC 60529
marking CE
maximum switching voltage 250 V AC
mechanical durability 10000000 cycles
minimum switching current 10 mA at 5 V DC
mounting position any position in relation to normal vertical mounting plane
mounting support 35 mm DIN rail conforming to EN/IEC 60715
net weight 0.07 kg
product certifications cULus, GL, CSA
product or component type single function relay
range of product Harmony Timer Relays
relative humidity 93-93 % without condensation conforming to IEC 60068-2-30
shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
tightening torque 0.6-1 N.m conforming to IEC 60947-1
width 17.5 mm
contacts type and composition 1 C/O
Supply frequency 50...60 Hz +/- 5 %
Maximum power consumption in W 0.6 W at 24 V DC
Reset time 120 ms on de-energisation typical
Immunity to microbreaks 20 ms
Power consumption in VA 0-32 VA at 240 V AC
Operating rate in Hz 10 Hz
Voltage range 0.85...1.1 Us
Temperature drift +/- 0.05 %/°C
Creepage distance 4 kV/3 conforming to IEC 60664-1
Voltage drift +/- 0.2 %/V
Time delay range 6...60 s, 1...10 h, 1...10 min, 6...60 min, 0.1...1 s, 1...10 s, 10...100 h
Nominal output current 8:00 AM
Housing material self-extinguishing
Output type relay
Time delay type C
Repeat accuracy +/- 0.5 % conforming to IEC 61812-1
Discrete output type relay
Setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Maximum delay response 100 ms
Maximum switching current 8 A AC/DC
Functionality off-delay timing
On-load factor 100%
vibration resistance 20 m/s² (f= 10-150 Hz) conforming to IEC 60068-2-6
electromagnetic compatibility electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2, electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2, susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3, electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4, electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4, 1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5, 1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5, conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6, voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11, voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11, conducted and radiated emissions: , class B, conforming to EN 55022
ambient air temperature for operation -20-60 °C
standards EN 61000-6-4, EN 61000-6-2, EN 61000-6-3, 2004/108/EC, 2006/95/EC, IEC 61812-1, EN 61000-6-1
local signalling LED indicator for on steady: relay energised, no timing in progress, LED indicator for flashing: timing in progress 80 % ON and 20 % OFF, LED indicator for pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) 5 % ON and 95 % OFF
safety reliability data B10d = 270000, MTTFd = 296.8 years
insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1
Impulse Duration 100 ms with load in parallel typical, 30 ms typical
Electrical Durability 100000 cycles (8 A at 250 V AC maximum) for resistive load

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review
You're reviewing: off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.

Frequently Bought Together

Off-delay Timing Relay - 0.05s…300h - 24…240V AC/DC - 1C/O
RE22R1CMR

In stock

AED 189.00
AED 303.64