[ics] Rated Service Breaking Capacity 70 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 32 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
breaking capacity 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking Capacity Code N
Connection Pitch 45 mm
Contact Position Indicator yes
Downside Connection front
Earth-leakage Protection without
[tr] long-time delay adjustment range 5.5-5.5 s at 7.2 x Ir, 8-8 s at 6 x Ir, 200-200 s at 1.5 x Ir
Protected Poles Description 3D
Trip Unit Name ETS 2.3
trip unit rating 630-630 A at 40 °C
trip unit technology electronic
Upside Connection front
utilisation category category A
ambient air temperature for storage -50-85 °C
compatibility code CVS630
connections - terminals screw connection
control type toggle
depth 110 mm
device application distribution
device short name CVS630N
Electrical Durability 4000 cycles 415 V In conforming to IEC 60947-2
height 255 mm
IP degree of protection IP40
mechanical durability 15000 cycles
mounting mode fixed
mounting support backplate
net weight 5.2 kg
network frequency 50/60 Hz
network type AC
Poles Description 3P
pollution degree 3 conforming to IEC 60664-1
product certifications GOST, IEC
product or component type circuit breaker
Protection Type instantaneous short-circuit protection, overload protection (long time), short time short-circuit protection
range EasyPact
range of product EasyPact CVS400...630
width 140 mm
Thermal memory yes
Trip unit protection functions LSoI
Long time delay adjustment type fixed
Instantaneous pick-up adjustment type Ii fixed
Short-time delay adjustment type fixed
Instantaneous pick-up adjustment range 11 x In
Long time pick-up adjustment range 250...630 A
Long time pick-up adjustment type Ir adjustable 9 settings
[Isd] short-time pick-up adjustment range 1.5...10 x Ir
Short-time pick-up adjustment type Isd adjustable 9 settings
ambient air temperature for operation -25-70 °C
standards EN 60947-2, IEC 60947-2
Electrical Shock Protection Class class II