calcPageSize())"
/>
No sellers found for this product.
Excl. Tax
- 1. ComPact NS is a range of circuit breakers for built-in power & energy metering
- 2. The solution covers ratings from 630 A to 3200 A
- 3. Micrologic electronic control unit provides electrical measurement and analysis functions
- 4. ComPact NS offers an optimized range of auxiliaries and accessories, field installable
- 5. Flexible installation, in any position, in a switchboard or wall-mounted
- 6. Sustainability with Green packaging and Green partnerships
- 7. Linked to Smart Panels, improves uptime with complete monitoring solution
circuit breaker Compact NS1600N - Micrologic 5.0 - 1600 A - 4 poles 4t
- Description
- Specifications
- Environmental Data
- Documents
- Reviews
Description
Overview
| Activity | PPCCB |
|---|---|
| net weight | 18 kg |
| Range | COMPACT |
| Product name | COMPACT NS |
| Range of product | COMPACT NS630B...1600 |
| Device short name | Compact NS1600N |
| Product or component type | CIRCUIT BREAKER |
| Device application | DISTRIBUTION |
| Number of poles | 4P |
| Protected poles description | 4D |
| Neutral position | LEFT |
| (In) rated current up to 65 °C | 1600 A AT 50 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 HZ |
| Network type | AC |
| Network frequency | 50/60 HZ |
| Suitability for isolation | YES CONFORMING TO EN/IEC 60947-2 |
| Utilisation category | CATEGORY B |
| [Icu] rated ultimate short-circuit breaking capacity | 30 KA ICU AT 660/690 V AC 50/60 HZ CONFORMING TO IEC 60947-250 KA ICU AT 380/415 V AC 50/60 HZ CONFORMING TO IEC 60947-250 KA ICU AT 440 V AC 50/60 HZ CONFORMING TO IEC 60947-285 KA ICU AT 220/240 V AC 50/60 HZ CONFORMING TO IEC 60947-240 KA ICU AT 500/525 V AC 50/60 HZ CONFORMING TO IEC 60947-2 |
| Performance level | N 50 KA 415 V AC |
| Trip unit name | MICROLOGIC 5.0 |
| Trip unit technology | ELECTRONIC |
| Trip unit protection functions | LSI |
| control type | TOGGLEROTARY HANDLE |
| Circuit breaker mounting mode | FIXED |
| [Ui] rated insulation voltage | 800 V AC 50/60 HZ CONFORMING TO IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 8 KV CONFORMING TO IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 30 KA AT 500/525 V AC 50/60 HZ CONFORMING TO IEC 60947-237 KA AT 220/240 V AC 50/60 HZ CONFORMING TO IEC 60947-237 KA AT 380/415 V AC 50/60 HZ CONFORMING TO IEC 60947-222 KA AT 660/690 V AC 50/60 HZ CONFORMING TO IEC 60947-237 KA AT 440 V AC 50/60 HZ CONFORMING TO IEC 60947-2 |
| [Icw] rated short-time withstand current | 19.2 KA 1 S CONFORMING TO IEC 60947-2 |
| Mechanical durability | 10000 CYCLES |
| Electrical durability | 1000 CYCLES AT 690 V IN2000 CYCLES AT 690 V IN/22000 CYCLES AT 440 V IN5000 CYCLES AT 440 V IN/2 |
| Power losses | 74 W |
| Mounting support | BACKPLATE |
| Upside connection | FRONT |
| Downside connection | FRONT |
| Connection pitch | 70 MM |
| Protection type | L : FOR OVERLOAD PROTECTION (LONG TIME)S : FOR SHORT TIME SHORT-CIRCUIT PROTECTIONI : FOR INSTANTANEOUS SHORT-CIRCUIT PROTECTION |
| Trip unit rating | 1600 A AT 50 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | ADJUSTABLE 9 SETTINGS |
| [Ir] long-time protection pick-up adjustment range | 0.4...1 X IN |
| Long-time protection delay adjustment type tr | ADJUSTABLE 9 SETTINGS |
| [tr] long-time protection delay adjustment range | 12.5…600 S AT 1.5 X IR0.5…24 S AT 6 X IR0.7…16.6 S AT 7.2 X IR |
| Thermal memory | 20 MN |
| Short-time protection pick-up adjustment type Isd | ADJUSTABLE 9 SETTINGS |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 X IR |
| Short-time protection delay adjustment type tsd | ADJUSTABLE |
| [tsd] Short-time protection delay adjustment range | 0.1…0.4 S I²T=ON0…0.4 S I²T=OFF |
| Instantaneous protection pick-up adjustment type Ii | ADJUSTABLE |
| [Ii] instantaneous protection pick-up adjustment range | 2...15 X INOFF |
| Earth-leakage protection | WITHOUT |
| Neutral protection settings | NO PROTECTION (3D)0.5 X IR (3D + N/2)1 X IR (4D) |
| Zone selective interlocking ZSI | WITHOUT |
| Auxiliary contact composition | 1 NO/NC |
| Local signalling | 4 LEDS (RED) FOR FAULT INDICATION1 LED (YELLOW) FOR OVERLOAD |
| Width (W) | 280 MM |
| Height (H) | 327 MM |
| Depth (D) | 147 MM |
| Net weight | 18 KG |
| Standards | EN/IEC 60947-2 |
| Product certifications | ASEFAASTA |
| Pollution degree | 3 CONFORMING TO IEC 60947 |
| IP degree of protection | IP40 CONFORMING TO IEC 60529 |
| IK degree of protection | IK07 CONFORMING TO EN 50102 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 M WITHOUT DERATING2000 M...5000 M WITH DERATING |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 30 CM |
| Package 1 Width | 40 CM |
| Package 1 Length | 60 CM |
| Package 1 Weight | 15.8 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| Mercury free | ✓ |
| RoHS exemption information | Yes (Download) |
| Halogen-free status | Product contains halogen above thresholds |
| PVC free | Yes |
| Silicone-free | No |
| REACh Regulation | REACh Declaration (Download) |
| EU RoHS Directive | EU RoHS Declaration (Download) |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | End of Life Information (Download) |
| Total lifecycle Carbon footprint | 1 590 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 220.96012784658413 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 221 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 4.55454095085897 |
| Carbon footprint of the distribution phase [A4] | 5 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 1.9731378345984818 |
| Carbon footprint of the installation phase [A5] | 2 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 1339.931832709839 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 1 340 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 23.01762684778266 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 23 kg CO2 eq. |
| SCIP Number | 76c2e213-3b51-4d8b-afdf-632ded42d731 |
| RoHS Eur Status | Compliant By Exemption |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Documents
Reviews
Description
Overview
| Activity | PPCCB |
|---|---|
| net weight | 18 kg |
| Range | COMPACT |
| Product name | COMPACT NS |
| Range of product | COMPACT NS630B...1600 |
| Device short name | Compact NS1600N |
| Product or component type | CIRCUIT BREAKER |
| Device application | DISTRIBUTION |
| Number of poles | 4P |
| Protected poles description | 4D |
| Neutral position | LEFT |
| (In) rated current up to 65 °C | 1600 A AT 50 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 HZ |
| Network type | AC |
| Network frequency | 50/60 HZ |
| Suitability for isolation | YES CONFORMING TO EN/IEC 60947-2 |
| Utilisation category | CATEGORY B |
| [Icu] rated ultimate short-circuit breaking capacity | 30 KA ICU AT 660/690 V AC 50/60 HZ CONFORMING TO IEC 60947-250 KA ICU AT 380/415 V AC 50/60 HZ CONFORMING TO IEC 60947-250 KA ICU AT 440 V AC 50/60 HZ CONFORMING TO IEC 60947-285 KA ICU AT 220/240 V AC 50/60 HZ CONFORMING TO IEC 60947-240 KA ICU AT 500/525 V AC 50/60 HZ CONFORMING TO IEC 60947-2 |
| Performance level | N 50 KA 415 V AC |
| Trip unit name | MICROLOGIC 5.0 |
| Trip unit technology | ELECTRONIC |
| Trip unit protection functions | LSI |
| control type | TOGGLEROTARY HANDLE |
| Circuit breaker mounting mode | FIXED |
| [Ui] rated insulation voltage | 800 V AC 50/60 HZ CONFORMING TO IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 8 KV CONFORMING TO IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 30 KA AT 500/525 V AC 50/60 HZ CONFORMING TO IEC 60947-237 KA AT 220/240 V AC 50/60 HZ CONFORMING TO IEC 60947-237 KA AT 380/415 V AC 50/60 HZ CONFORMING TO IEC 60947-222 KA AT 660/690 V AC 50/60 HZ CONFORMING TO IEC 60947-237 KA AT 440 V AC 50/60 HZ CONFORMING TO IEC 60947-2 |
| [Icw] rated short-time withstand current | 19.2 KA 1 S CONFORMING TO IEC 60947-2 |
| Mechanical durability | 10000 CYCLES |
| Electrical durability | 1000 CYCLES AT 690 V IN2000 CYCLES AT 690 V IN/22000 CYCLES AT 440 V IN5000 CYCLES AT 440 V IN/2 |
| Power losses | 74 W |
| Mounting support | BACKPLATE |
| Upside connection | FRONT |
| Downside connection | FRONT |
| Connection pitch | 70 MM |
| Protection type | L : FOR OVERLOAD PROTECTION (LONG TIME)S : FOR SHORT TIME SHORT-CIRCUIT PROTECTIONI : FOR INSTANTANEOUS SHORT-CIRCUIT PROTECTION |
| Trip unit rating | 1600 A AT 50 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | ADJUSTABLE 9 SETTINGS |
| [Ir] long-time protection pick-up adjustment range | 0.4...1 X IN |
| Long-time protection delay adjustment type tr | ADJUSTABLE 9 SETTINGS |
| [tr] long-time protection delay adjustment range | 12.5…600 S AT 1.5 X IR0.5…24 S AT 6 X IR0.7…16.6 S AT 7.2 X IR |
| Thermal memory | 20 MN |
| Short-time protection pick-up adjustment type Isd | ADJUSTABLE 9 SETTINGS |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 X IR |
| Short-time protection delay adjustment type tsd | ADJUSTABLE |
| [tsd] Short-time protection delay adjustment range | 0.1…0.4 S I²T=ON0…0.4 S I²T=OFF |
| Instantaneous protection pick-up adjustment type Ii | ADJUSTABLE |
| [Ii] instantaneous protection pick-up adjustment range | 2...15 X INOFF |
| Earth-leakage protection | WITHOUT |
| Neutral protection settings | NO PROTECTION (3D)0.5 X IR (3D + N/2)1 X IR (4D) |
| Zone selective interlocking ZSI | WITHOUT |
| Auxiliary contact composition | 1 NO/NC |
| Local signalling | 4 LEDS (RED) FOR FAULT INDICATION1 LED (YELLOW) FOR OVERLOAD |
| Width (W) | 280 MM |
| Height (H) | 327 MM |
| Depth (D) | 147 MM |
| Net weight | 18 KG |
| Standards | EN/IEC 60947-2 |
| Product certifications | ASEFAASTA |
| Pollution degree | 3 CONFORMING TO IEC 60947 |
| IP degree of protection | IP40 CONFORMING TO IEC 60529 |
| IK degree of protection | IK07 CONFORMING TO EN 50102 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 M WITHOUT DERATING2000 M...5000 M WITH DERATING |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 30 CM |
| Package 1 Width | 40 CM |
| Package 1 Length | 60 CM |
| Package 1 Weight | 15.8 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| Mercury free | ✓ |
| RoHS exemption information | Yes (Download) |
| Halogen-free status | Product contains halogen above thresholds |
| PVC free | Yes |
| Silicone-free | No |
| REACh Regulation | REACh Declaration (Download) |
| EU RoHS Directive | EU RoHS Declaration (Download) |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | End of Life Information (Download) |
| Total lifecycle Carbon footprint | 1 590 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 220.96012784658413 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 221 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 4.55454095085897 |
| Carbon footprint of the distribution phase [A4] | 5 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 1.9731378345984818 |
| Carbon footprint of the installation phase [A5] | 2 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 1339.931832709839 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 1 340 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 23.01762684778266 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 23 kg CO2 eq. |
| SCIP Number | 76c2e213-3b51-4d8b-afdf-632ded42d731 |
| RoHS Eur Status | Compliant By Exemption |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |