TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 380...400 V AC coil

LC1K0910Q7
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Description

TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 380...400 V AC coil

Product Details

Activity PPCTR
Net weight 0.18 kg
Product or Component Type contactor
[Uc] Control Circuit Voltage 380...400 V AC 50/60 Hz
auxiliary contacts type type instantaneous 1 NO
Pole Contact Composition 3 NO
Protective Treatment TC conforming to IEC 60068,TC conforming to DIN 50016
Insulation Resistance > 10 MOhm for signalling circuit
Minimum Switching Current 5 mA for signalling circuit
Minimum Switching Voltage 17 V for signalling circuit
Poles Description 3P
Average Impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Auxiliary Contact Composition 1 NO
Contactor Application motor control,resistive load
Non Overlap Distance 0.5 mm
Signalling Circuit Frequency <= 400 Hz
Range of Product TeSys K
Standards EN/IEC 60947-4-1,GB/T 14048.4,UL 60947-4-1,CSA C22.2 No 60947-4-1,JIS C8201-4-1
Mechanical Robustness shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27,shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27,shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27,shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27,shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27,shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27,vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6,vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Associated Fuse Rating 25 A gG at <= 440 V for power circuit,25 A aM for power circuit,10 A gG for signalling circuit conforming to IEC 60947,10 A gG for signalling circuit conforming to VDE 0660
Control Circuit Type AC at 50/60 Hz
Heat Dissipation 1.3-1.3 W
Operating Time 10...20 ms coil de-energisation and NO opening,10...20 ms coil energisation and NO closing
Rated Breaking Capacity 110 A at 415 V conforming to IEC 60947,110 A at 440 V conforming to IEC 60947,80 A at 500 V conforming to IEC 60947,110 A at 220...230 V conforming to IEC 60947,110 A at 380...400 V conforming to IEC 60947,70 A at 660...690 V conforming to IEC 60947
Flame Retardance V1 conforming to UL 94,requirement 2 conforming to NF F 16-101,requirement 2 conforming to NF F 16-102
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Overvoltage Category III
Utilisation category AC-1,AC-4,AC-3,AC-3e
Operating altitude 2000 m without derating
Compatibility code LC1K
Device Application control
Range TeSys

Seller Information

Documents

Reviews

Write Your Own Review
You're reviewing: TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 380...400 V AC coil
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.