TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 115A/1000V AC-3 (55kW@400V). It provides a 220V 50/60Hz AC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirrror certified), power connection by screw connectors 2 inputs, control connection by screw clamp terminals. For operating rates until 2400 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (120mm width), mounting on 2 DIN-rails or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Product Details

[ie] Rated Operational Current 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[uc] Control Circuit Voltage 220 V AC 50/60 Hz , 220 V AC 50/60 Hz , 220 V AC 50/60 Hz
[ue] Rated Operational Voltage power circuit: <= 1000 V AC 25...400 Hz
[ui] Rated Insulation Voltage power circuit: 600 V CSA certified
[uimp] Rated Impulse Withstand Voltage 8 kV conforming to IEC 60947
Ambient Air Temperature for Operation -40-60 °C
Ambient Air Temperature for Storage -60-80 °C
Auxiliary Contacts Type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
Climatic Withstand conforming to IACS E10
Compatibility Code LC1D
Depth 136 mm
Device Short Name LC1D
Electrical Durability 0.8 Mcycles 200 A AC-1 at Ue <= 440 V
Fire Resistance 850 °C conforming to IEC 60695-2-1
Flame Retardance V1 conforming to UL 94
Height 19.000 cm
Ip Degree of Protection IP20 front face conforming to IEC 60529
Mechanical Durability 8 Mcycles
Mechanical Robustness vibrations contactor open: 2 Gn, 5...300 Hz
Mounting Support rail
Net Weight 2.5 kg
Overvoltage Category III
Poles Description 3P
Pollution Degree 3
Power Range 30-50 kW at 200-240 V 3 phases
Product Certifications RINA
Product Name TeSys D
Product or Component Type contactor
Range TeSys
Range of Product TeSys D
Standards CSA C22.2 No 14
Tightening Torque control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Utilisation Category AC-4
Width 17.500 cm
[icw] Rated Short-time Withstand Current 250 A 40 °C - 10 min for power circuit
Connections - Terminals control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
[ith] Conventional Free Air Thermal Current 200 A (at 60 °C) for power circuit
Associated Fuse Rating 250 A gG at <= 690 V coordination type 1 for power circuit
Auxiliary Contact Composition 1 NO + 1 NC
Average Impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit
Coil Technology built-in bidirectional peak limiting diode suppressor
Contact Compatibility M13
Contactor Application motor control|resistive load
Contactor Coil Voltage 220 V AC standard
Control Circuit Type AC at 50/60 Hz
Control Circuit Voltage Limits 0.3...0.5 Uc (-40-70 °C):drop-out AC 50/60 Hz
Heat Dissipation 3-8 W at 50/60 Hz
Hold-in Power Consumption in Va 2-18 VA 60 Hz cos phi 0.3 (at 20 °C)
Inrush Power in Va 280-350 VA 60 Hz cos phi 0.8 (at 20 °C)
Insulation Resistance > 10 MOhm for signalling circuit
Irms Rated Making Capacity 1260 A at 440 V for power circuit conforming to IEC 60947
Maximum Operating Rate 2400 cyc/h 60 °C
Minimum Switching Current 5 mA for signalling circuit
Minimum Switching Voltage 17 V for signalling circuit
Motor Power Hp 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
Motor Power Kw 30 kW at 220...230 V AC 50/60 Hz (AC-3)
Motor Starter Type direct on-line contactor
Non-overlap Time 1.5 ms on de-energisation between NC and NO contact
Operating Altitude 0...3000 m
Operating Time 6...20 ms opening
Pole Contact Composition 3 NO
Power Dissipation Per Pole 24 W AC-1
Protective Cover with
Protective Treatment TH conforming to IEC 60068-2-30
Rated Breaking Capacity 1100 A at 440 V for power circuit conforming to IEC 60947
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
Signalling Circuit Frequency 25...400 Hz
[Ue] rated operational voltage power circuit: <= 1000 V AC 25...400 Hz , power circuit: <= 1000 V AC 25...400 Hz , power circuit: <= 1000 V AC 25...400 Hz , power circuit: <= 1000 V AC 25...400 Hz , power circuit: <= 300 V DC , power circuit: <= 300 V DC , power circuit: <= 300 V DC
Utilisation category AC-4|AC-1|AC-3|AC-3e
Range TeSys
Range of Product TeSys Deca
[ie] Rated Operational Current 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Length 21.500 cm
Activity code PPCTR
Poles description 3P

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review