Activity |
PPCCB |
[uimp] Rated Impulse Withstand Voltage |
8 kV |
[us] Rated Supply Voltage |
220...240 V AC 50/60 Hz 55...110 % , 220...240 V AC 50/60 Hz 55...110 % , 220...240 V AC 50/60 Hz 55...110 % , 220...240 V AC 50/60 Hz 55...110 % |
Ambient Air Temperature for Operation |
-35-70 °C |
Ambient Air Temperature for Storage |
-55-85 °C |
Compatibility Code |
RH10M |
Depth |
74 mm |
Device Short Name |
RH10M |
Electromagnetic Compatibility |
conducted and radiated emissions: , B, conforming to CISPR 11 |
Height |
8.0 cm |
Ik Degree of Protection |
IK07 conforming to EN 50102 |
Ip Degree of Protection |
IP40 on front face: conforming to EN/IEC 60529 |
Mechanical Robustness |
fire resistance conforming to IEC 60695-2-1 |
Minimum Load |
10 mA at 12 V , 10 mA at 12 V |
Mounting Support |
DIN rail |
Net Weight |
0.3 kg |
Overvoltage Category |
IV |
Product or Component Type |
residual current protection relay |
Range |
VigiPacT |
Range Compatibility |
TOA earth leakage current sensor |
Tightening Torque |
auxiliary power supply: 0.6-0.6 N.m top |
Width |
8.6 cm |
Wire Stripping Length |
auxiliary power supply: 7 mm for top connection |
9 Mm Pitches |
6 |
Connections - Terminals |
auxiliary power supply: terminal block cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12 |
[ithe] Conventional Enclosed Thermal Current |
8 A |
Earth Leakage Current |
0.03-0.03 A |
Earthing System |
TN-S|IT|TT |
Electrical Shock Protection Class |
class II |
Monitoring |
electronics (continuous) |
Network Rated Voltage |
1000-1000 V - AC at 50/60 Hz (maximum) |
Power Consumption in Va |
4 VA |
Relay Application |
protection relay |
Reset |
manual reset |
Residual Earth-leakage Sensitity Adjustment Type |
fixed |
Residual Earth-leakage Time Delay Adjustment Type |
instantaneous |
Tamperproof of Settings |
protected by sealable cover |
Test Function |
local |
Type of Measurement |
earth fault current internal measurement, range: 80...100 % |
Type of Setting |
none |
Earth-leakage protection class |
type A |
Earth-leakage Protection Class |
type A |
Pollution Degree |
3 conforming to IEC 60664-1 |
Relative Humidity |
95-95 % at 55-55 °C |
Range |
VigiPacT |
Range Compatibility |
VigiPacT TOA earth leakage current sensor , VigiPacT TOA earth leakage current sensor , VigiPacT TOA earth leakage current sensor , VigiPacT A earth leakage current sensor , VigiPacT A earth leakage current sensor , VigiPacT A earth leakage current sensor , VigiPacT L earth leakage current sensor , VigiPacT L earth leakage current sensor , VigiPacT L earth leakage current sensor |
Network Rated Voltage |
1000-1000 V - AC at 50/60 Hz (maximum) , 1000-1000 V - AC at 50/60 Hz (maximum) , 1000-1000 V - AC at 50/60 Hz (maximum) , 1000-1000 V - AC at 50/60 Hz (maximum) , 1000-1000 V - AC at 400 Hz (maximum) , 1000-1000 V - AC at 400 Hz (maximum) , 1000-1000 V - AC at 400 Hz (maximum) , 1000-1000 V - AC at 400 Hz (maximum) |
Residual Earth-leakage Time Delay Adjustment Type |
instantaneous |
Length |
9.0 cm |