| Range of product | HARMONY CONTROL RELAYS |
|---|---|
| Relay type | CONTROL RELAY |
| Product or component type | 3-PHASE CONTROL RELAY |
| Relay name | RM10TE |
| Relay monitored parameters | PHASE SEQUENCEPHASE FAILURE DETECTIONASYMMETRYOVERVOLTAGE AND UNDERVOLTAGE DETECTION |
| Product specific application | FOR 3-PHASE SUPPLY |
| Supply voltage limits | 183…528 V AC, 3 PHASES |
| Supply frequency | 47...63 HZ |
| Power consumption in VA | 0…4.5 VA |
| Measurement range | 208...480 V AC |
| Voltage detection threshold | < 175 V AC |
| Hysteresis | 2 % |
| Measurement error | < 0.05 %/°C WITH TEMPERATURE VARIATION< 1 % OVER THE WHOLE RANGE WITH VOLTAGE VARIATION |
| Time delay type | ADJUSTABLE 0...100 S, +/- 10 % OF THE FULL SCALE VALUE |
| Setting accuracy of time delay | 10 % |
| Reset time | 1.5 S TIME DELAY |
| Response time | < 550 MS (IN THE EVENT OF A FAULT) |
| Output contacts | 1 C/O |
| nominal output current | 5 A |
| Switching capacity in VA | 1250 VA |
| Electrical durability | 100000 CYCLES |
| Mechanical durability | 10000000 CYCLES |
| Electromagnetic compatibility | CONFORMING TO IEC 61000-6-4 CONFORMING TO IEC 61000-6-3 CONFORMING TO IEC 61000-6-2 |
| Standards | IEC 60255-1 |
| Product certifications | cULusCEUKCACCC |
| Marking | CULUSCEUKCACCC |
| Ambient air temperature for storage | -40…70 °C-40…70 °C |
| Ambient air temperature for operation | -15…60 °C |
| Relative humidity | 10…95 % |
| IP degree of protection | IP20 (TERMINALS)IP40 (CASING) |
| Pollution degree | 2 |
| Overvoltage category | II |
| Dielectric test voltage | 1.89 KV, 1 MIN AC 50 HZ |
| Insulation resistance | > 100 MOHM AT 500 V DC |
| [Ui] rated insulation voltage | 400 V |
| Connections - terminals | SCREW TERMINALS, 2 X 0.5...2 X 1.5 MM² (20 AWG...16 AWG) SOLID WITH OR WITHOUT CABLE END |
| Tightening torque | 0.5…0.7 N.M |
| Housing material | POLYCARBONATE |
| Local signalling | LED (GREEN) FOR ST (STATUS)LED (RED) FOR OVERVOLTAGELED (RED) FOR UNDERVOLTAGELED (RED) FOR ALARM ASYMMENTRY FAILURE TRIGGERED |
| Mounting support | 35 MM SYMMETRICAL DIN RAIL CONFORMING TO IEC 60715 |
| Reliability data | MTTFD = 158 YEARS |
| Height | 90 MM88.9 MM |
| Width | 17.5 MM17.8 MM |
| Depth | 58.5 MM58.4 MM |
| Net weight | 0.075 KG0.08 KG |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.500 CM |
| Package 1 Width | 7.000 CM |
| Package 1 Length | 11.000 CM |
| Package 1 Weight | 85.000 G |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 15.000 CM |
| Package 2 Width | 30.000 CM |
| Package 2 Length | 40.000 CM |
| Package 2 Weight | 4.727 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| Mercury free | ✓ |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | End of Life Information (Download) |
| Recyclability potential, in % | 70 |
| Total lifecycle Carbon footprint | 81 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 0 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 0 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0 kg CO2 eq. |
| REACh Regulation | Reference contains Substances of Very High Concern above the threshold (Download) |
| EU RoHS Directive | Compliant By Exemption (Download) |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Reviews
Description
Overview
| Range of product | HARMONY CONTROL RELAYS |
|---|---|
| Relay type | CONTROL RELAY |
| Product or component type | 3-PHASE CONTROL RELAY |
| Relay name | RM10TE |
| Relay monitored parameters | PHASE SEQUENCEPHASE FAILURE DETECTIONASYMMETRYOVERVOLTAGE AND UNDERVOLTAGE DETECTION |
| Product specific application | FOR 3-PHASE SUPPLY |
| Supply voltage limits | 183…528 V AC, 3 PHASES |
| Supply frequency | 47...63 HZ |
| Power consumption in VA | 0…4.5 VA |
| Measurement range | 208...480 V AC |
| Voltage detection threshold | < 175 V AC |
| Hysteresis | 2 % |
| Measurement error | < 0.05 %/°C WITH TEMPERATURE VARIATION< 1 % OVER THE WHOLE RANGE WITH VOLTAGE VARIATION |
| Time delay type | ADJUSTABLE 0...100 S, +/- 10 % OF THE FULL SCALE VALUE |
| Setting accuracy of time delay | 10 % |
| Reset time | 1.5 S TIME DELAY |
| Response time | < 550 MS (IN THE EVENT OF A FAULT) |
| Output contacts | 1 C/O |
| nominal output current | 5 A |
| Switching capacity in VA | 1250 VA |
| Electrical durability | 100000 CYCLES |
| Mechanical durability | 10000000 CYCLES |
| Electromagnetic compatibility | CONFORMING TO IEC 61000-6-4 CONFORMING TO IEC 61000-6-3 CONFORMING TO IEC 61000-6-2 |
| Standards | IEC 60255-1 |
| Product certifications | cULusCEUKCACCC |
| Marking | CULUSCEUKCACCC |
| Ambient air temperature for storage | -40…70 °C-40…70 °C |
| Ambient air temperature for operation | -15…60 °C |
| Relative humidity | 10…95 % |
| IP degree of protection | IP20 (TERMINALS)IP40 (CASING) |
| Pollution degree | 2 |
| Overvoltage category | II |
| Dielectric test voltage | 1.89 KV, 1 MIN AC 50 HZ |
| Insulation resistance | > 100 MOHM AT 500 V DC |
| [Ui] rated insulation voltage | 400 V |
| Connections - terminals | SCREW TERMINALS, 2 X 0.5...2 X 1.5 MM² (20 AWG...16 AWG) SOLID WITH OR WITHOUT CABLE END |
| Tightening torque | 0.5…0.7 N.M |
| Housing material | POLYCARBONATE |
| Local signalling | LED (GREEN) FOR ST (STATUS)LED (RED) FOR OVERVOLTAGELED (RED) FOR UNDERVOLTAGELED (RED) FOR ALARM ASYMMENTRY FAILURE TRIGGERED |
| Mounting support | 35 MM SYMMETRICAL DIN RAIL CONFORMING TO IEC 60715 |
| Reliability data | MTTFD = 158 YEARS |
| Height | 90 MM88.9 MM |
| Width | 17.5 MM17.8 MM |
| Depth | 58.5 MM58.4 MM |
| Net weight | 0.075 KG0.08 KG |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.500 CM |
| Package 1 Width | 7.000 CM |
| Package 1 Length | 11.000 CM |
| Package 1 Weight | 85.000 G |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 15.000 CM |
| Package 2 Width | 30.000 CM |
| Package 2 Length | 40.000 CM |
| Package 2 Weight | 4.727 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| Mercury free | ✓ |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | End of Life Information (Download) |
| Recyclability potential, in % | 70 |
| Total lifecycle Carbon footprint | 81 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 0 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 0 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0 kg CO2 eq. |
| REACh Regulation | Reference contains Substances of Very High Concern above the threshold (Download) |
| EU RoHS Directive | Compliant By Exemption (Download) |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |