OVER UNDER TEMP 1C/O 24-240VAC/DC
- Description
- Specifications
- Environmental Data
- Documents
- Reviews
Description
Overview
| Range | Harmony |
|---|---|
| [in] Rated Current | 5 A |
| [uc] Control Circuit Voltage | 24...240 V |
| Housing Material | self-extinguishing plastic |
| Minimum Switching Current | 10 mA at 5 V DC |
| Product or Component Type | temperature control relay |
| Range of product | HARMONY CONTROL RELAYS |
| Relay type | TEMPERATURE CONTROL RELAYS |
| Product or component type | ELEVATOR MACHINE ROOM TEMPERATURE CONTROL RELAY |
| Product specific application | FOR ELEVATOR MACHINE ROOMS AND 3-PHASE SUPPLIES |
| Relay name | RM35AT |
| Relay monitored parameters | UNDER TEMPERATURE: -1...11°COVER TEMPERATURE: 34...46°C |
| Time delay range | 0.1...10 S ADJUSTABLE DELAY (TOLERANCE: 0...10 % OF THE FULL SCALE VALUE) |
| Switching capacity in VA | 1250 VA |
| Minimum switching current | 10 MA AT 5 V DC |
| Maximum power consumption in VA | 3.5 VA AC |
| Utilisation category | AC-12 CONFORMING TO IEC 60947-5-1AC-13 CONFORMING TO IEC 60947-5-1AC-14 CONFORMING TO IEC 60947-5-1AC-15 CONFORMING TO IEC 60947-5-1DC-12 CONFORMING TO IEC 60947-5-1DC-13 CONFORMING TO IEC 60947-5-1DC-14 CONFORMING TO IEC 60947-5-1 |
| time delay | ADJUSTABLE 1...10 S TT- TIME DELAY UPON FAULT |
| Measurement range | +/- 1...46 °C |
| Reset time | 8 S |
| Maximum switching voltage | 250 V AC/DC |
| [Us] rated supply voltage | 24...240 V AC/DC |
| [Un] rated nominal voltage | 24...240 V AC/DC 50/60 HZ, NON SELF-POWERED |
| Supply voltage limits | 20.4…264 V AC21.6…264 V DC |
| Maximum power consumption in W | 0.6 W DC |
| Resistance across terminals | 1.33 KOHM AT TEMPERATURE |
| Width | 35 MM |
| Output contacts | 1 C/O |
| Contacts material | CADMIUM FREE |
| Nominal output current | 5 A |
| delay at power up | 0.2 S |
| Measurement accuracy | +/- 2 °C |
| Temperature probe type | PT 100 - 3-WIRE |
| Installed device | PT 100 PROBE CABLE LENGTH |
| Marking | CE : EMC 89/336/EECCE : 73/23/EEC |
| Overvoltage category | III CONFORMING TO IEC 60664-1 |
| Insulation resistance | > 500 MOHM AT 500 V DC BETWEEN SUPPLY AND RELAY OUTPUT CONFORMING TO IEC 60255-5> 500 MOHM AT 500 V DC BETWEEN MEASUREMENT AND RELAY OUTPUT CONFORMING TO IEC 60664-1> 1 MOHM AT 500 V DC BETWEEN SUPPLY AND MEASUREMENT CONFORMING TO IEC 60255-5> 500 MOHM AT 500 V DC BETWEEN SUPPLY AND RELAY OUTPUT CONFORMING TO IEC 60664-1> 500 MOHM AT 500 V DC BETWEEN MEASUREMENT AND RELAY OUTPUT CONFORMING TO IEC 60255-5> 1 MOHM AT 500 V DC BETWEEN SUPPLY AND MEASUREMENT CONFORMING TO IEC 60664-1 |
| [Ui] rated insulation voltage | 250 V CONFORMING TO IEC 60664-1 |
| operating voltage tolerance | - 10 % + 10 % UN DC- 15 % + 10 % UN AC |
| Supply frequency | 50/60 HZ +/- 10 % |
| Insulation | GALVANIC INSULATION BETWEEN SUPPLY AND MEASUREMENT |
| Operating position | ANY POSITION WITHOUT DERATING |
| Connections - terminals | SCREW TERMINALS, 1 X 0.5...1 X 4 MM² (AWG 20...AWG 11) SOLID WITHOUT CABLE ENDSCREW TERMINALS, 2 X 0.5...2 X 2.5 MM² (AWG 20...AWG 14) SOLID WITHOUT CABLE ENDSCREW TERMINALS, 1 X 0.2...1 X 2.5 MM² (AWG 24...AWG 12) FLEXIBLE WITH CABLE ENDSCREW TERMINALS, 2 X 0.2...2 X 1.5 MM² (AWG 24...AWG 16) FLEXIBLE WITH CABLE END |
| Tightening torque | 0.6…1 N.M CONFORMING TO IEC 60947-1 |
| Housing material | POLYCARBONATE |
| local signalling | 1 LED GREEN FOR POWER ON1 LED YELLOW FOR CORRECT TEMPERATURE (HIGH R1)1 LED YELLOW FOR CORRECT TEMPERATURE (LOW R2) |
| Mounting support | 35 MM SYMMETRICAL DIN RAIL CONFORMING TO IEC 60715 |
| Electrical durability | 100000 CYCLES |
| Mechanical durability | 30000000 CYCLES |
| Control type | WITHOUT TEST BUTTON |
| Immunity to microbreaks | 10 MS |
| Electromagnetic compatibility | EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS CONFORMING TO IEC 61000-6-4EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS CONFORMING TO IEC 61000-6-3IMMUNITY FOR INDUSTRIAL ENVIRONMENTS CONFORMING TO NF EN/IEC 61000-6-2 |
| Standards | IEC 60255-6NF EN 60255-6 |
| Product certifications | GOSTGLC-TickULCSA |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -20…50 °C |
| Vibration resistance | 0.35 MM (F= 5…57.6 HZ) CONFORMING TO IEC 60068-2-6/IEC 60255-21-11 GN (F= 57.6…150 HZ) CONFORMING TO IEC 60068-2-6/IEC 60255-21-1 |
| Shock resistance | 15 GN FOR 11 MS CONFORMING TO IEC 60255-21-1 |
| IP degree of protection | IP20 (TERMINALS) CONFORMING TO IEC 60529IP30 (CASING) CONFORMING TO IEC 60529 |
| Pollution degree | 3 CONFORMING TO IEC 60664-1 |
| Dielectric test voltage | 2 KV, 1 MIN AC 50 HZ |
| Non-dissipating shock wave | 4 KV |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.0 CM |
| Package 1 Width | 4.6 CM |
| Package 1 Length | 9.7 CM |
| Package 1 Weight | 127.0 G |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 30.0 CM |
| Package 2 Width | 30.0 CM |
| Package 2 Length | 40.0 CM |
| Package 2 Weight | 6.732 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| Mercury free | ✓ |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | End of Life Information (Download) |
| Total lifecycle Carbon footprint | 29 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 8.551813554392087 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 9 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.016607337114601512 |
| Carbon footprint of the distribution phase [A4] | 0 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.04120758435136707 |
| Carbon footprint of the installation phase [A5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 20.104799999999997 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 20 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.2384205206515416 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.2 kg CO2 eq. |
| SCIP Number | 5e3fdf99-611b-4d07-ad17-6eba84ab488b |
| REACh Regulation | Reference contains Substances of Very High Concern above the threshold (Download) |
| EU RoHS Directive | Compliant By Exemption (Download) |
Reviews
Description
Overview
| Range | Harmony |
|---|---|
| [in] Rated Current | 5 A |
| [uc] Control Circuit Voltage | 24...240 V |
| Housing Material | self-extinguishing plastic |
| Minimum Switching Current | 10 mA at 5 V DC |
| Product or Component Type | temperature control relay |
| Range of product | HARMONY CONTROL RELAYS |
| Relay type | TEMPERATURE CONTROL RELAYS |
| Product or component type | ELEVATOR MACHINE ROOM TEMPERATURE CONTROL RELAY |
| Product specific application | FOR ELEVATOR MACHINE ROOMS AND 3-PHASE SUPPLIES |
| Relay name | RM35AT |
| Relay monitored parameters | UNDER TEMPERATURE: -1...11°COVER TEMPERATURE: 34...46°C |
| Time delay range | 0.1...10 S ADJUSTABLE DELAY (TOLERANCE: 0...10 % OF THE FULL SCALE VALUE) |
| Switching capacity in VA | 1250 VA |
| Minimum switching current | 10 MA AT 5 V DC |
| Maximum power consumption in VA | 3.5 VA AC |
| Utilisation category | AC-12 CONFORMING TO IEC 60947-5-1AC-13 CONFORMING TO IEC 60947-5-1AC-14 CONFORMING TO IEC 60947-5-1AC-15 CONFORMING TO IEC 60947-5-1DC-12 CONFORMING TO IEC 60947-5-1DC-13 CONFORMING TO IEC 60947-5-1DC-14 CONFORMING TO IEC 60947-5-1 |
| time delay | ADJUSTABLE 1...10 S TT- TIME DELAY UPON FAULT |
| Measurement range | +/- 1...46 °C |
| Reset time | 8 S |
| Maximum switching voltage | 250 V AC/DC |
| [Us] rated supply voltage | 24...240 V AC/DC |
| [Un] rated nominal voltage | 24...240 V AC/DC 50/60 HZ, NON SELF-POWERED |
| Supply voltage limits | 20.4…264 V AC21.6…264 V DC |
| Maximum power consumption in W | 0.6 W DC |
| Resistance across terminals | 1.33 KOHM AT TEMPERATURE |
| Width | 35 MM |
| Output contacts | 1 C/O |
| Contacts material | CADMIUM FREE |
| Nominal output current | 5 A |
| delay at power up | 0.2 S |
| Measurement accuracy | +/- 2 °C |
| Temperature probe type | PT 100 - 3-WIRE |
| Installed device | PT 100 PROBE CABLE LENGTH |
| Marking | CE : EMC 89/336/EECCE : 73/23/EEC |
| Overvoltage category | III CONFORMING TO IEC 60664-1 |
| Insulation resistance | > 500 MOHM AT 500 V DC BETWEEN SUPPLY AND RELAY OUTPUT CONFORMING TO IEC 60255-5> 500 MOHM AT 500 V DC BETWEEN MEASUREMENT AND RELAY OUTPUT CONFORMING TO IEC 60664-1> 1 MOHM AT 500 V DC BETWEEN SUPPLY AND MEASUREMENT CONFORMING TO IEC 60255-5> 500 MOHM AT 500 V DC BETWEEN SUPPLY AND RELAY OUTPUT CONFORMING TO IEC 60664-1> 500 MOHM AT 500 V DC BETWEEN MEASUREMENT AND RELAY OUTPUT CONFORMING TO IEC 60255-5> 1 MOHM AT 500 V DC BETWEEN SUPPLY AND MEASUREMENT CONFORMING TO IEC 60664-1 |
| [Ui] rated insulation voltage | 250 V CONFORMING TO IEC 60664-1 |
| operating voltage tolerance | - 10 % + 10 % UN DC- 15 % + 10 % UN AC |
| Supply frequency | 50/60 HZ +/- 10 % |
| Insulation | GALVANIC INSULATION BETWEEN SUPPLY AND MEASUREMENT |
| Operating position | ANY POSITION WITHOUT DERATING |
| Connections - terminals | SCREW TERMINALS, 1 X 0.5...1 X 4 MM² (AWG 20...AWG 11) SOLID WITHOUT CABLE ENDSCREW TERMINALS, 2 X 0.5...2 X 2.5 MM² (AWG 20...AWG 14) SOLID WITHOUT CABLE ENDSCREW TERMINALS, 1 X 0.2...1 X 2.5 MM² (AWG 24...AWG 12) FLEXIBLE WITH CABLE ENDSCREW TERMINALS, 2 X 0.2...2 X 1.5 MM² (AWG 24...AWG 16) FLEXIBLE WITH CABLE END |
| Tightening torque | 0.6…1 N.M CONFORMING TO IEC 60947-1 |
| Housing material | POLYCARBONATE |
| local signalling | 1 LED GREEN FOR POWER ON1 LED YELLOW FOR CORRECT TEMPERATURE (HIGH R1)1 LED YELLOW FOR CORRECT TEMPERATURE (LOW R2) |
| Mounting support | 35 MM SYMMETRICAL DIN RAIL CONFORMING TO IEC 60715 |
| Electrical durability | 100000 CYCLES |
| Mechanical durability | 30000000 CYCLES |
| Control type | WITHOUT TEST BUTTON |
| Immunity to microbreaks | 10 MS |
| Electromagnetic compatibility | EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS CONFORMING TO IEC 61000-6-4EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS CONFORMING TO IEC 61000-6-3IMMUNITY FOR INDUSTRIAL ENVIRONMENTS CONFORMING TO NF EN/IEC 61000-6-2 |
| Standards | IEC 60255-6NF EN 60255-6 |
| Product certifications | GOSTGLC-TickULCSA |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -20…50 °C |
| Vibration resistance | 0.35 MM (F= 5…57.6 HZ) CONFORMING TO IEC 60068-2-6/IEC 60255-21-11 GN (F= 57.6…150 HZ) CONFORMING TO IEC 60068-2-6/IEC 60255-21-1 |
| Shock resistance | 15 GN FOR 11 MS CONFORMING TO IEC 60255-21-1 |
| IP degree of protection | IP20 (TERMINALS) CONFORMING TO IEC 60529IP30 (CASING) CONFORMING TO IEC 60529 |
| Pollution degree | 3 CONFORMING TO IEC 60664-1 |
| Dielectric test voltage | 2 KV, 1 MIN AC 50 HZ |
| Non-dissipating shock wave | 4 KV |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.0 CM |
| Package 1 Width | 4.6 CM |
| Package 1 Length | 9.7 CM |
| Package 1 Weight | 127.0 G |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 30.0 CM |
| Package 2 Width | 30.0 CM |
| Package 2 Length | 40.0 CM |
| Package 2 Weight | 6.732 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| Mercury free | ✓ |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | End of Life Information (Download) |
| Total lifecycle Carbon footprint | 29 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 8.551813554392087 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 9 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.016607337114601512 |
| Carbon footprint of the distribution phase [A4] | 0 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.04120758435136707 |
| Carbon footprint of the installation phase [A5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 20.104799999999997 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 20 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.2384205206515416 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.2 kg CO2 eq. |
| SCIP Number | 5e3fdf99-611b-4d07-ad17-6eba84ab488b |
| REACh Regulation | Reference contains Substances of Very High Concern above the threshold (Download) |
| EU RoHS Directive | Compliant By Exemption (Download) |