GV5P150F

GV5P150F 3P 36kA Motor Circuit Breaker

45% Off
1/1
GV5P150F

GV5P150F 3P 36kA Motor Circuit Breaker

In stock
SKU
GV5P150F
Regular Price SAR2,905.00 Special Price SAR1,597.75
To View the best prices please sign in or register.
CHECK DELIVERY TIME & COD AVAILABILITY

Add to compare

No sellers found for this product.

GV5P150F 3P 36kA Motor Circuit Breaker

Regular Price SAR2,905.00 Special Price SAR1,597.75
45% Off

Description

Motor circuit breaker, TeSys GV5, 3P, 150A, Icu 36kA, thermal magnetic

Product details

  • Activity
    PPCTR
  • Weight (in Kg)
    0.003 kg
  • [ith] Conventional Free Air Thermal Current
    150 A conforming to IEC 60947-4-1
  • Product Name
    TeSys GV5, TeSys Giga
  • Range of Product
    TeSys GV5
  • [ue] Rated Operational Voltage
    690 V AC 50/60 Hz
  • Product or Component Type
    motor circuit breaker
  • Range
    TeSys
  • Device Application
    motor protection
  • Direct Connector
    without
  • Control Type
    direct rotary handle
  • Fire Resistance
    960 °C conforming to IEC 60695-2-11
  • Magnetic Tripping Current
    2250-2250 A
  • Maximum Operating Rate
    25 cyc/h
  • Phase Failure Sensitivity
    yes conforming to IEC 60947-4-1
  • Poles Description
    3P
  • Rated Duty
    continuous
  • Operating Altitude
    5000 m
  • Net Weight
    2.4 kg
  • Suitability for Isolation
    yes conforming to EN/IEC 60947-2
  • Trip Unit Technology
    electronic
  • Mechanical Durability
    40000 cycles
  • [ics] Rated Service Short-Circuit Breaking Capacity
    100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Standards
    EN/IEC 60947-1#|#EN/IEC 60947-2#|#EN/IEC 60947-4-1#|#UL 60947-4-1#|#CSA C22.2 No 60947-4-1
  • Power Dissipation per Pole
    9.2 W
  • Utilisation Category
    category A conforming to IEC 60947-2
  • Ambient Air Temperature for Operation
    -25-70 °C
  • [uimp] Rated Impulse withstand Voltage
    8 kV
  • Ambient Air Temperature for Storage
    -50-85 °C
  • Breaking Capacity
    36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Product Certifications
    IECEE CB Scheme#|#EAC (pending)
  • [ui] Rated Insulation Voltage
    800 V AC 50/60 Hz conforming to IEC 60947-2
  • [in] Rated Current
    150 A at 65 °C
  • Height
    161 mm
  • Depth
    155 mm
  • Width
    105 mm
more specification
less specification

Reviews

Write Your Own Review
You're reviewing:GV5P150F 3P 36kA Motor Circuit Breaker
Your Rating

* Required Field