Miniature circuit-breaker, Acti9 C120N, 1P, 100 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)

Product Details

Activity HDCFD
[in] Rated Current 100 A at 30 °C
[ui] Rated Insulation Voltage 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[uimp] Rated Impulse withstand Voltage 6 kV conforming to EN/IEC 60947-2
Ambient Air Temperature for Operation -25-70 °C
[ue] Rated Operational Voltage 380...415 V AC 50/60 Hz, 220...240 V AC 50/60 Hz, 125 V DC, <= 144 V DC, 12 V DC, 230...400 V AC 50/60 Hz, 130 V AC 50/60 Hz, 12 V AC 50/60 Hz
Ambient Air Temperature for Storage -40-85 °C
Breaking Capacity Code N
Comb Busbar and Distribution Block Compatibility NO
Compatibility Code C120
Control Type toggle
Curve Code C
Breaking Capacity 3 kA Icu at 380...415 V AC 50/60 Hz IT conforming to EN/IEC 60947-2, 20 kA Icu at 130 V AC 50/60 Hz conforming to EN/IEC 60947-2, 15 kA Icu at 12 V DC conforming to EN/IEC 60947-2, 15 kA Icu at 125 V DC conforming to EN/IEC 60947-2, 10 kA Icu at <= 144 V DC conforming to EN/IEC 60947-2, 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2, 20 kA Icu at 12 V AC 50/60 Hz conforming to EN/IEC 60947-2, 10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Depth 73 mm
Device Short Name C120N
Device Application distribution
IP Degree of Protection IP20 conforming to IEC 60529
Net Weight 0.205 kg
Mechanical Durability 20000 cycles
Mounting Mode clip-on
Network Frequency 50/60 Hz
Poles Description 1P
Network Type AC
Product or Component Type miniature circuit-breaker
9 mm Pitches 3
Number of Protected Poles 1
Product Name C120
Range Acti9
Relative Humidity 95-95 % at 55-55 °C
Mounting Support 35 mm symmetrical DIN rail
Standards EN/IEC 60898-1#|#EN/IEC 60947-2
Tightening Torque 3.5-3.5 N.m
Trip Unit Technology thermal-magnetic
Wire Stripping Length 15 mm
Colour white
Tropicalisation 2 conforming to IEC 60068-1
[lcs] Rated Service Breaking Capacity 10 kA 100 % conforming to EN/IEC 60947-2 - <= 144 V DC, 15 kA 100 % conforming to EN/IEC 60947-2 - 12 V DC, 15 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC, 15 kA 75 % conforming to EN/IEC 60947-2 - 12 V AC 50/60 Hz, 15 kA 75 % conforming to EN/IEC 60947-2 - 130 V AC 50/60 Hz, 2.25 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz, 7.5 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz, 7500 A 75 % conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz
Connections - Terminals tunnel type terminals1-50 mm² rigid, tunnel type terminals1.5-35 mm² flexible