Activity |
IDVSD |
[us] Rated Supply Voltage |
380...480 V - 15...10 % |
Ambient Air Temperature for Operation |
-10-40 °C (without derating), 40-50 °C (with derating factor) |
Ambient Air Temperature for Storage |
-25-70 °C |
Weight (in Kg) |
53.0 kg |
Motor Power kW |
4 kW |
Power Dissipation in W |
176 W |
Device Short Name |
ATV212 |
Power Range |
4-6 kW at 380-440 V 3 phases, 4-6 kW at 480-500 V 3 phases |
Product or Component Type |
variable speed drive |
Product Specific Application |
pumps and fans in HVAC |
Range of Product |
Altivar 212 |
Assembly Style |
with heat sink |
Communication Port Protocol |
METASYS N2#|#BACnet#|#APOGEE FLN#|#Modbus#|#LonWorks |
Connector Type |
1 open style#|#1 RJ45 |
Discrete Input Type |
F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm, R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm, RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm |
Discrete Output Number |
2 |
Discrete Output Type |
configurable relay logic: (FLA, FLC) NO - 100000 cycles, configurable relay logic: (FLB, FLC) NC - 100000 cycles, configurable relay logic: (RY, RC) NO - 100000 cycles |
Height |
184 mm |
Electromagnetic Compatibility |
electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6, voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
Marking |
CE |
Minimum Switching Current |
3 mA at 24 V DC for configurable relay logic |
Motor Starter Type |
variable speed drive |
Network Frequency |
47.5...63 Hz |
Network Number of Phases |
3 phases |
Net Weight |
3.35 kg |
Noise Level |
51 dB conforming to 86/188/EEC |
Operating Position |
vertical +/- 10 degree |
Product Certifications |
CSA#|#NOM 117#|#UL#|#C-Tick |
Operating Altitude |
1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m, <= 1000 m without derating |
Supply Frequency |
50...60 Hz - 5...5 % |
Transmission Rate |
9600 bps or 19200 bps |
Maximum Switching Current |
5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R), 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R), 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R), 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) |
Protection Type |
overheating protection: drive, line supply undervoltage: drive, against input phase loss: drive, thermal protection: motor, motor phase break: motor, with PTC probes: motor, thermal power stage: drive, short-circuit between motor phases: drive, input phase breaks: drive, overcurrent between output phases and earth: drive, overvoltages on the DC bus: drive, break on the control circuit: drive, against exceeding limit speed: drive, line supply overvoltage and undervoltage: drive |
Depth |
150 mm |
Width |
142 mm |
Standards |
IEC 61800-3 environments 2 category C2#|#IEC 61800-3 environments 1 category C1#|#IEC 61800-3 environments 1 category C3#|#IEC 61800-3 environments 2 category C3#|#IEC 61800-3 category C3#|#EN 61800-3 environments 1 category C1#|#IEC 61800-3 category C2#|#EN 61800-3#|#EN 61800-3 environments 1 category C3#|#EN 61800-3 environments 2 category C2#|#UL Type 1#|#IEC 61800-3#|#EN 61800-3 environments 2 category C1#|#IEC 61800-3 environments 1 category C2#|#EN 61800-3 environments 2 category C3#|#EN 55011 class A group 1#|#EN 61800-3 category C2#|#EN 61800-3 environments 1 category C2#|#IEC 61800-3 environments 2 category C1#|#IEC 61800-5-1#|#EN 61800-5-1#|#EN 61800-3 category C3 |
Discrete Input Logic |
positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1), negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1) |