Time delay auxiliary contact block, TeSys D, 1NO + 1NC, on delay 1-30s, front, screw clamp terminals

LADS2
Be the first one to review this.

Excl. Tax

login_green To View the best prices please Sign in / Register.
loader
Loading...
loader
Loading...

Product Selection Summary

Product Details

Activity PPCTR
Part Number LADS2
[Ith] conventional free air thermal current 10 A (at 60 °C)
[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1, 600 V conforming to UL 60947-5-1, 600 V conforming to CSA C22.2 No 60947-5-1
ambient air temperature for storage -60-80 °C
colour dark grey
connections - terminals screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end, screw clamp terminals 1 cable(s) 1-2.5 mm²flexible without cable end, screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end, screw clamp terminals 2 cable(s) 1-2.5 mm²flexible without cable end, screw clamp terminals 1 cable(s) 1-2.5 mm²rigid, screw clamp terminals 2 cable(s) 1-2.5 mm²rigid, screw clamp terminals
depth 61 mm
device application star delta starter
height 48 mm
IP degree of protection IP20 conforming to IEC 60529
Irms rated making capacity 140 A at <= 690 V AC conforming to IEC 60947-5-1, 250 A at <= 690 V DC conforming to IEC 60947-5-1
mechanical durability 5 Mcycles
minimum switching current 5 mA
minimum switching voltage 17 V
non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact, 1.5 ms on energisation no overlap between NC and NO contact
operating altitude 3000 m
pole contact composition 1 NO + 1 NC
product certifications IECEE CB Scheme, UL, CSA, CCC, EAC, UKCA
product or component type time delay auxiliary contact block
protective treatment TH conforming to IEC 60068
range TeSys, TeSys Deca
range of product TeSys Deca, TeSys F, TeSys Deca control relay
rated operational voltage limits 690 V AC 25...400 Hz
tightening torque 1.7 N.m - with screwdriver flat Ø 6 mm, 1.7 N.m - with screwdriver Philips No 2, 1.7 N.m - with screwdriver pozidriv No 2
width 44 mm
Time delay range 1...30 s
Permissible short-time rating 100 A 60 °C 1 s, 120 A 60 °C 500 ms, 140 A 60 °C 100 ms
Auxiliary contacts operation time delay
Shielding continuity terminal without
Timer type on delay
ambient air temperature for operation -40-70 °C
standards CSA C22.2 No 60947-5-1, GB/T 14048.5, EN/IEC 60947-5-1
[Ie] rated operational current 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, 0.1 A at 600 V DC-13
environmental characteristic normal environment
insulation resistance > 10 MOhm
Mounting Location front
Range Compatibility TeSys D CAD, TeSys D LC1D, TeSys F LC1F, TeSys F CR1F, TeSys Deca CAD, TeSys Deca LC1D

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Frequently Bought Together

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 415 V AC coil

check-small In stock

OMR 23.451
OMR 1.261
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 415 V AC coil

check-small In stock

OMR 15.765
OMR 9.548
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 48 V AC coil

check-small In stock

OMR 15.765
OMR 0.856
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 240 V AC 50/60 Hz coil

check-small In stock

OMR 150.209
OMR 8.126
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 220 V AC 50/60 Hz coil

check-small In stock

OMR 150.209
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 220 V AC 50/60 Hz coil

check-small In stock

OMR 66.951
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 40 A - 220 V AC 50/60 Hz coil

check-small In stock

OMR 47.237
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 110 V AC 50/60 Hz coil

check-small In stock

OMR 127.974
OMR 6.885