Regulated Power Supply, 100-240V AC, 24V 2.5 A, single phase, Modular

ABLM1A24025
Be the first one to review this.

Excl. Tax

login_green To View the best prices please Sign in / Register.
loader
Loading...

Product Details

Activity IDMST
Part Number ABLM1A24025
connections - terminals screw connection: 0.5...2.5 mm², (AWG 20...AWG 14) without wire end ferrule for output, screw connection: 0.5...1.5 mm², (AWG 20...AWG 16) with wire end ferrule for output, screw connection: 0.5...1.5 mm², (AWG 20...AWG 16) for input
current consumption < 1.5 A 115 V AC, < 1 A 230 V AC
depth 55.6 mm
dielectric strength 3000 V AC input/output
efficiency 90 % at 115 V AC, 90 % at 230 V AC
height 91 mm
holding time > 20 ms 115 V AC, > 60 ms 230 V AC
input protection type integrated fuse (not interchangeable) 3.15 A, external protection (recommended) 20 A Curve B, external protection (recommended) 20 A Curve C, external protection (recommended) 10 A Curve B, external protection (recommended) 6 A Curve C
input voltage 100...240 V AC single phase, 100...240 V AC 2 phases
input voltage limits 90...264 V AC
inrush current 30 A at 115 V, 60 A at 230 V
IP degree of protection IP20
line and load regulation < 0.5 % network in line, < 1 % network 0 to 100 % load
meantime between failure [MTBF] 1300000 h at 25 °C, full load, 700000 h at 55 °C, 80 % load
mounting support top hat type TH35-15 rail conforming to IEC 60715, top hat type TH35-7.5 rail conforming to IEC 60715, double-profile DIN rail, panel mounting
net weight 0.221 kg
operating altitude < 2000 m overvoltage category III, 2000 m...5000 m overvoltage category II
output coupling serial, parallel
output voltage 24 V DC
output voltage limits 24...28 V
pollution degree 2
power dissipation in W 6.5 W
power supply output current 2.5 A
power supply type regulated switch mode
product certifications CE, cUL listed, cUL recognized, RCM, CB Scheme, EAC, KC, NEC: class 2
product or component type power supply
range of product Modicon Power Supply
rated power in W 60 W
service life 10 year(s)
shock resistance 100 m/s² for 11 ms
width 53 mm
Supply SELV conforming to EN/IEC 60950-1, SELV conforming to EN/IEC 60204-1, SELV conforming to IEC 60364-4-41
Enclosure material plastic
Electromagnetic emission conducted emissions conforming to EN 61000-6-3, radiated emissions conforming to EN 61000-6-4
Maximum leakage current 0.25 mA 240 V AC
Residual ripple < 100 mV
Network frequency limits 50-60 Hz
Variant option modular
Load capacitance 3000 µF
Power factor 0.50 at 115 V AC, 0.39 at 230 V AC
vibration resistance 3 mm (f= 2-9 Hz) conforming to IEC 60721-3-3, 10 m/s² (f= 9-200 Hz) conforming to IEC 60721-3-3
output protection type against overload and short-circuits, protection technology: automatic reset, against over temperature, protection technology: manual reset, against overvoltage, protection technology: manual reset
status LED 1 LED (green) output voltage
electromagnetic compatibility immunity to electrostatic discharge - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2, immunity to electrostatic discharge - test level: 9 kV (air discharge) conforming to EN/IEC 61000-4-2, electromagnetic field immunity test - test level: 10 V/m (80 MHz...2 GHz) conforming to EN/IEC 61000-4-3, electromagnetic field immunity test - test level: 5 V/m (2...2.7 GHz) conforming to EN/IEC 61000-4-3, electromagnetic field immunity test - test level: 3 V/m (2.7...6 GHz) conforming to EN/IEC 61000-4-3, immunity to fast transients - test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4, surge immunity test - test level: 3 kV (between power supply and earth) conforming to EN/IEC 61000-4-5, surge immunity test - test level: 1.5 kV (between phases) conforming to EN/IEC 61000-4-5, immunity to conducted disturbances - test level: 10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6, immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8, immunity to voltage dips - test level: 100 % (1 cycle) conforming to EN/IEC 61000-4-11, immunity to voltage dips - test level: 60 % (10 cycles) conforming to EN/IEC 61000-4-11, immunity to voltage dips - test level: 30 % (25 cycles) conforming to EN/IEC 61000-4-11, disturbing field emission conforming to EN 55016-2-3, limits for harmonic current emissions conforming to EN 61000-3-2, conducted disturbance emission conforming to EN 55016-1-2, conducted disturbance emission conforming to EN 55016-2-1
ambient air temperature for operation -25--10 °C with current derating of 1 % per °C mounting position A < 2000 m, -10-55 °C without current derating mounting position A < 2000 m, 55-70 °C with current derating of 2.67 % per °C mounting position A < 2000 m
standards EN 62368-1, EN/IEC 61010-1, EN 61010-2-201, EN/IEC 61204-3, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3, UL 62368-1, UL 61010-1, UL 61010-2-201, CSA C22.2 No 62368-1, CSA C22.2 No 61010-1, CSA C22.2 No 61010-2-201, EN/IEC 62368-1
Electrical Shock Protection Class class II without PE connection
Earthing System TN, TT, IT

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Frequently Bought Together

Regulated Power Supply, 100-240V AC, 24V 1.2 A, single phase, Modular

check-small In stock

OMR 51.574
Regulated Power Supply, 100-240V AC, 24V 0.4 A, single phase, Modular

check-small In stock

OMR 33.100