Logic controller, Modicon M241, 24 IO relay Ethernet

TM241CE24R
Be the first one to review this.

Excl. Tax

login_green To View the best prices please Sign in / Register.
loader
Loading...

Product Details

Activity IDMST
Resistance to electrostatic discharge 8 kV in air conforming to EN/IEC 61000-4-2, 4 kV on contact conforming to EN/IEC 61000-4-2
Part Number TM241CE24R
[Us] rated supply voltage 100...240 V AC
ambient air temperature for storage -25-70 °C
depth 95 mm
height 90 mm
IP degree of protection IP20 with protective cover in place
marking CE
mounting support top hat type TH35-15 rail conforming to IEC 60715, top hat type TH35-7.5 rail conforming to IEC 60715, plate or panel with fixing kit
net weight 0.53 kg
network frequency 50/60 Hz
operating altitude 0...2000 m
output voltage limits 125 V DC relay output, 30 V DC transistor output, 277 V AC relay output
pollution degree 2
product certifications RCM, CSA, IACS E10, cULus
product or component type logic controller
range of product Modicon M241
relative humidity 10-95 %, without condensation (in operation), 10-95 %, without condensation (in storage)
shock resistance 15 gn for 11 ms
supply voltage limits 85-264 V
width 150 mm
Discrete output current 2 A for relay output (Q4...Q9), 0.1 A for fast output (PTO mode) (TR0...TR3), 0.5 A for transistor output (TR0...TR3)
Supply (serial 1)serial link supply: 5 V, <200 mA
Data backed up 128 MB built-in flash memory for backup of user programs
Data storage equipment <= 16 GB SD card (optional)
Reset time 10 ms automatic reset output, 12 s automatic reset fast output
Clock drift <= 60 s/month at 25-25 °C
Immunity to microbreaks 10 ms
Discrete input current 5 mA for input
Voltage state 1 guaranteed >= 15 V for input
Cycle time 10 ms 16 EtherNet/IP, 64 ms 64 Modbus TCP
Discrete input voltage 24 V
Backup time 2 years at 25 °C
Voltage state 0 guaranteed <= 5 V for input
Discrete input number 14 , discrete input 8 fast input conforming to IEC 61131-2 Type 1
Resistance to electromagnetic fields 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3, 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3, 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
Surge withstand 2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5, 2 kV relay output common mode conforming to EN/IEC 61000-4-5, 1 kV shielded cable common mode conforming to EN/IEC 61000-4-5, 1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5, 1 kV relay output differential mode conforming to EN/IEC 61000-4-5, 1 kV input common mode conforming to EN/IEC 61000-4-5, 1 kV transistor output common mode conforming to EN/IEC 61000-4-5
Resistance to fast transients 2 kV (power lines) conforming to EN/IEC 61000-4-4, 2 kV (relay output) conforming to EN/IEC 61000-4-4, 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4, 1 kV (serial link) conforming to EN/IEC 61000-4-4, 1 kV (input) conforming to EN/IEC 61000-4-4, 1 kV (transistor output) conforming to EN/IEC 61000-4-4
Electromagnetic emission conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10-150 kHz conforming to EN/IEC 55011, conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5-30 MHz conforming to EN/IEC 55011, conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines) at 0.15-0.5 MHz conforming to EN/IEC 55011, conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines) at 0.5-300 MHz conforming to EN/IEC 55011, radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30-230 MHz conforming to EN/IEC 55011, conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150-1500 kHz conforming to EN/IEC 55011, radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 230-1000 MHz conforming to EN/IEC 55011
Discrete output type relay, transistor
Discrete output number 6 relay, 4 transistor 4 fast output
Sensor power supply 24-24 V DC at 400 mA supplied by the controller
Realtime clock with
Discrete input logic sink or source
Discrete input voltage type DC
Maximum number of I/O expansion module 7 (local I/O-Architecture), 14 (remote I/O-Architecture)
Counting input number 4 fast input (HSC mode) at 200 kHz, 14 standard input at 1 kHz
Resistance to conducted disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6, 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL), 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Maximum cable distance between devices unshielded cable: <50 m for input, shielded cable: <10 m for fast input, unshielded cable: <50 m for output, shielded cable: <3 m for fast output
Discrete output logic positive logic (source)
Positioning functions PTO function 4 channel(s) (positioning frequency: 100 kHz)
Accuracy +/- 0.1 % at 0.02-0.1 kHz for fast output, +/- 1 % at 0.1-1 kHz for fast output
Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15-15 m for RS485, 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3-3 m for RS232, 480 Mbit/s for bus length of 3-3 m for USB, 10/100 Mbit/s for Ethernet
Discrete I/O number 24
Application structure 8 external event tasks, 3 cyclic master tasks + 1 freewheeling task, 8 event tasks, 4 cyclic master tasks
Configurable filtering time 1 µs for fast input
Discrete output voltage 5...125 V DC for relay output, 5...250 V AC for relay output, 24 V DC for transistor output
Memory capacity 8 MB for program, 64 MB for system memory RAM
Maximum output frequency 1 kHz for transistor output, 20 kHz for fast output (PWM mode), 100 kHz for fast output (PLS mode)
Execution time for 1 KInstruction 0.3 ms for event and periodic task, 0.7 ms for other instruction
Port Ethernet 10BASE-T/100BASE-TX - 1 port(s) copper cable
Communication service FDR, DHCP server via TM4 Ethernet switch network module, DHCP client embedded Ethernet port, SMS notifications, updating firmware, SNMP client/server, programming, NGVL, monitoring, IEC VAR ACCESS, FTP client/server, downloading, SQL client, Modbus TCP client I/O scanner, Ethernet/IP originator I/O scanner embedded Ethernet port, Ethernet/IP target, Modbus TCP server and Modbus TCP slave, send and receive email from the controller based on TCP/UDP library, web server (WebVisu & XWeb system), OPC UA server, DNS client
Web services web server
Maximum number of connections 8 Modbus server, 8 SoMachine protocol, 10 web server, 4 FTP server, 16 Ethernet/IP target, 8 Modbus client
Number of slave 64 Modbus TCP: , 16 EtherNet/IP:
vibration resistance 3.5 mm at 5-8.4 Hz on symmetrical rail, 3 gn at 8.4-150 Hz on symmetrical rail, 3.5 mm at 5-8.4 Hz on panel mounting, 3 gn at 8.4-150 Hz on panel mounting
ambient air temperature for operation -10-50 °C (vertical installation), -10-55 °C (horizontal installation)
standards ANSI/ISA 12-12-01, CSA C22.2 No 142, CSA C22.2 No 213, EN/IEC 61131-2:2007, Marine specification (LR, ABS, DNV, GL), UL 1604, UL 508
local signalling 1 LED (green) for PWR, 1 LED (green) for RUN, 1 LED (red) for module error (ERR), 1 LED (red) for I/O error (I/O), 1 LED (green) for SD card access (SD), 1 LED (red) for BAT, 1 LED (green) for SL1, 1 LED (green) for SL2, 1 LED (red) for bus fault on TM4 (TM4), 1 LED per channel (green) for I/O state, 1 LED (green) for Ethernet port activity
Electrical Connection removable screw terminal blockfor inputs and outputs (pitch 5.08 mm), removable screw terminal blockfor connecting the 24 V DC power supply (pitch 5.08 mm)
Integrated Connection Type non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface , non isolated serial link serial 2 with removable screw terminal block connector and RS485 interface , USB port with mini B USB 2.0 connector, Ethernet with RJ45 connector
Input Impedance 4.7 kOhm for input
Storage Altitude 0-3000 m
Communication Port Protocol non isolated serial link: Modbus master/slave
Control Signal Type A/B at 100 kHz for fast input (HSC mode), pulse/direction at 200 kHz for fast input (HSC mode), single phase at 200 kHz for fast input (HSC mode)
Insulation between supply and internal logic at 500 V AC, non-insulated between supply and ground

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Frequently Bought Together

remote receiver module TM3 - bus

check-small In stock

OMR 97.761
remote transmitter module TM3 - bus

check-small In stock

OMR 94.297
Analogue input cartridge, Modicon M241, 2 temperature inputs

check-small In stock

OMR 64.661