AUXILIARY CONTACT OF or SD NSXm & PP-B
calcPageSize())"
/>
Further offers for this product
Excl. Tax
In Stock
No sellers found for this product.
Excl. Tax
auxiliary contact (spring) OF/SD - 1 NO/NC
AUXILIARY CONTACT OF or SD NSXm & PP-B
- Description
- Specifications
- Environmental Data
- Documents
- Reviews
Description
It is a single standard auxiliary contact that provides two remote information of the circuit breaker status. It is used on Compact NSXm and PowerPact B devices. The OF contact (open/closed) indicates the position of the circuit breaker main contacts. The SD contact (trip indication) indicates if the circuit breaker has tripped. There is one auxiliary contact model for OF and SD information, depending on where it is fitted in the device. This auxiliary is a common point changeover type contact with 1 normally open contact and 1 normally closed contact. The rated current is 5A and the minimum load is 2mA at 17 VDC. Utilization categories are AC12/AC13/DC12/DC13/DC14. Compact NSXm embeds 2 auxiliary contacts and their presence is visible on the front face through green flags. It complies with IEC 60947-5-1 standard.
Overview
| Product Name | AUXILIARY CONTACT OF or SD NSXm & PP-B |
|---|---|
| Tax Class | GST-18 |
| Current Rating | 160A |
| Short Description | auxiliary contact (spring) OF/SD - 1 NO/NC |
| Product or component type | AUXILIARY CONTACT |
| Device short name | SDOF |
| Device application | BREAKER STATUS MONITORING |
| Range compatibility | POWERPACT POWERPACT BCOMPACT COMPACT NSXM |
| Signal contacts composition | 1 NO/NC |
| Fault type | OVERLOADSHORT-CIRCUIT |
| Local signalling | ON/OFF INDICATION FOR OPEN/CLOSETRIP INDICATOR FOR RELAY TRIP INDICATOR |
| Auxiliary contacts type | STANDARD |
| Mounting mode | CLIP-ON |
| [Ith] conventional free air thermal current | 5 A |
| Breaking capacity (A) | AC-12: 5 A AT 24 V AC 50/60 HZAC-12: 5 A AT 48 V AC 50/60 HZAC-12: 5 A AT 110...127 V AC 50/60 HZAC-12: 5 A AT 220/240 V AC 50/60 HZAC-12: 5 A AT 380/440 V AC 50/60 HZAC-12: 5 A AT 660/690 V AC 50/60 HZAC-15: 5 A AT 24 V AC 50/60 HZAC-15: 5 A AT 48 V AC 50/60 HZAC-15: 4 A AT 110...127 V AC 50/60 HZAC-15: 3 A AT 220/240 V AC 50/60 HZAC-15: 2.5 A AT 380/440 V AC 50/60 HZAC-15: 0.1 A AT 660/690 V AC 50/60 HZDC-12: 5 A AT 24 V DC 50/60 HZDC-12: 2.5 A AT 48 V DC 50/60 HZDC-12: 0.6 A AT 110 V DC 50/60 HZDC-12: 0.3 A AT 250 V DCDC-13: 2.5 A AT 24 V DCDC-13: 1.2 A AT 48 V DCDC-13: 0.35 A AT 110 V DCDC-13: 0.05 A AT 250 V DCDC-14: 1 A AT 24 V DCDC-14: 0.2 A AT 48 V DCDC-14: 0.05 A AT 110 V DCDC-14: 0.03 A AT 250 V DC |
| Minimum load | 2 MA AT 17 V DC |
| Auxiliary connection terminal | SPRING |
| Wire stripping length | 8 MM FOR FRONT CONNECTION |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 1.200 CM |
| Package 1 Width | 7.500 CM |
| Package 1 Length | 10.500 CM |
| Package 1 Weight | 25.000 G |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 4.000 CM |
| Package 2 Width | 18.000 CM |
| Package 2 Length | 29.500 CM |
| Package 2 Weight | 270.000 G |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 110 |
| Package 3 Height | 30.000 CM |
| Package 3 Width | 30.000 CM |
| Package 3 Length | 40.000 CM |
| Package 3 Weight | 3.594 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| REACh free of SVHC | ✓ |
| Toxic heavy metal free | ✓ |
| Mercury free | ✓ |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | No need of specific recycling operations |
| Recyclability potential, in % | 39 |
| Total lifecycle Carbon footprint | 2 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 0.08987521796683069 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 0.1 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.004860294778781507 |
| Carbon footprint of the distribution phase [A4] | 0 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.02266719577412608 |
| Carbon footprint of the installation phase [A5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 1.389498292719039 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 1 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.01914097934428922 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0 kg CO2 eq. |
| REACh Regulation | Free of Substances of Very High Concern above the threshold (Download) |
| EU RoHS Directive | Compliant (Download) |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Reviews
Description
It is a single standard auxiliary contact that provides two remote information of the circuit breaker status. It is used on Compact NSXm and PowerPact B devices. The OF contact (open/closed) indicates the position of the circuit breaker main contacts. The SD contact (trip indication) indicates if the circuit breaker has tripped. There is one auxiliary contact model for OF and SD information, depending on where it is fitted in the device. This auxiliary is a common point changeover type contact with 1 normally open contact and 1 normally closed contact. The rated current is 5A and the minimum load is 2mA at 17 VDC. Utilization categories are AC12/AC13/DC12/DC13/DC14. Compact NSXm embeds 2 auxiliary contacts and their presence is visible on the front face through green flags. It complies with IEC 60947-5-1 standard.
Overview
| Product Name | AUXILIARY CONTACT OF or SD NSXm & PP-B |
|---|---|
| Tax Class | GST-18 |
| Current Rating | 160A |
| Short Description | auxiliary contact (spring) OF/SD - 1 NO/NC |
| Product or component type | AUXILIARY CONTACT |
| Device short name | SDOF |
| Device application | BREAKER STATUS MONITORING |
| Range compatibility | POWERPACT POWERPACT BCOMPACT COMPACT NSXM |
| Signal contacts composition | 1 NO/NC |
| Fault type | OVERLOADSHORT-CIRCUIT |
| Local signalling | ON/OFF INDICATION FOR OPEN/CLOSETRIP INDICATOR FOR RELAY TRIP INDICATOR |
| Auxiliary contacts type | STANDARD |
| Mounting mode | CLIP-ON |
| [Ith] conventional free air thermal current | 5 A |
| Breaking capacity (A) | AC-12: 5 A AT 24 V AC 50/60 HZAC-12: 5 A AT 48 V AC 50/60 HZAC-12: 5 A AT 110...127 V AC 50/60 HZAC-12: 5 A AT 220/240 V AC 50/60 HZAC-12: 5 A AT 380/440 V AC 50/60 HZAC-12: 5 A AT 660/690 V AC 50/60 HZAC-15: 5 A AT 24 V AC 50/60 HZAC-15: 5 A AT 48 V AC 50/60 HZAC-15: 4 A AT 110...127 V AC 50/60 HZAC-15: 3 A AT 220/240 V AC 50/60 HZAC-15: 2.5 A AT 380/440 V AC 50/60 HZAC-15: 0.1 A AT 660/690 V AC 50/60 HZDC-12: 5 A AT 24 V DC 50/60 HZDC-12: 2.5 A AT 48 V DC 50/60 HZDC-12: 0.6 A AT 110 V DC 50/60 HZDC-12: 0.3 A AT 250 V DCDC-13: 2.5 A AT 24 V DCDC-13: 1.2 A AT 48 V DCDC-13: 0.35 A AT 110 V DCDC-13: 0.05 A AT 250 V DCDC-14: 1 A AT 24 V DCDC-14: 0.2 A AT 48 V DCDC-14: 0.05 A AT 110 V DCDC-14: 0.03 A AT 250 V DC |
| Minimum load | 2 MA AT 17 V DC |
| Auxiliary connection terminal | SPRING |
| Wire stripping length | 8 MM FOR FRONT CONNECTION |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 1.200 CM |
| Package 1 Width | 7.500 CM |
| Package 1 Length | 10.500 CM |
| Package 1 Weight | 25.000 G |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 4.000 CM |
| Package 2 Width | 18.000 CM |
| Package 2 Length | 29.500 CM |
| Package 2 Weight | 270.000 G |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 110 |
| Package 3 Height | 30.000 CM |
| Package 3 Width | 30.000 CM |
| Package 3 Length | 40.000 CM |
| Package 3 Weight | 3.594 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| REACh free of SVHC | ✓ |
| Toxic heavy metal free | ✓ |
| Mercury free | ✓ |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | No need of specific recycling operations |
| Recyclability potential, in % | 39 |
| Total lifecycle Carbon footprint | 2 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 0.08987521796683069 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 0.1 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.004860294778781507 |
| Carbon footprint of the distribution phase [A4] | 0 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.02266719577412608 |
| Carbon footprint of the installation phase [A5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 1.389498292719039 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 1 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.01914097934428922 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0 kg CO2 eq. |
| REACh Regulation | Free of Substances of Very High Concern above the threshold (Download) |
| EU RoHS Directive | Compliant (Download) |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |