CONTROLLER DEVICENET 5 100A 115 230VAC
calcPageSize())"
/>
Further offers for this product
Inclusive of all Taxes
In Stock
No sellers found for this product.
Inclusive of all Taxes
CONTROLLER DEVICENET 5 100A 115 230VAC
- Specifications
- Environmental Data
- Documents
- Reviews
Overview
| Product Name | CONTROLLER DEVICENET 5 100A 115 230VAC |
|---|---|
| Tax Class | GST-18 |
| Country of Origin | China |
| Manufacturer | Schneider Electric |
| Range | TESYS |
| Product name | TESYS T |
| Device short name | LTMR |
| Product or component type | MOTOR CONTROLLER |
| Device application | EQUIPMENT MONITORING AND CONTROL |
| Measurement current | 5…100 A |
| [Us] rated supply voltage | 100...240 V AC 50/60 HZ |
| Current consumption | 8...62.8 MA |
| Supply voltage limits | 93.5…264 V AC |
| Communication port protocol | DEVICENET |
| Bus type | DEVICENET ISO 1198 INTERFACE, ADDRESSING 1...64, TRANSMISSION RATE 125...500 KBIT/S, TERMINAL BLOCK WITH 4 TWISTED SHIELDED PAIRS CABLE |
| [Ui] rated insulation voltage | 690 V CONFORMING TO EN/IEC 60947-1690 V CONFORMING TO CSA C22.2 NO 14690 V CONFORMING TO UL 508 |
| [Uimp] rated impulse withstand voltage | 4 KV SUPPLY, INPUTS AND OUTPUTS CONFORMING TO EN/IEC 60947-4-16 KV CURRENT OR VOLTAGE MEASUREMENT CIRCUIT CONFORMING TO EN/IEC 60947-4-10.8 KV COMMUNICATION CIRCUIT CONFORMING TO EN/IEC 60947-4-1 |
| Short-circuit withstand | 100 KA CONFORMING TO EN/IEC 60947-4-1 |
| Associated fuse rating | 4 A GG FOR OUTPUT0.5 A GG FOR CONTROL CIRCUIT |
| Protection type | PHASE FAILUREOVERLOAD (LONG TIME)LOAD FLUCTUATIONTHERMAL OVERLOAD PROTECTIONPOWER FACTOR VARIATIONOVERLOADLOCKED ROTORTHERMAL PROTECTIONEARTH-LEAKAGE PROTECTIONPHASE UNBALANCEREVERSE POLARITY PROTECTION |
| Network and machine diagnosis type | MOTOR CONTROL COMMAND RECORDINGTRIP HISTORY INFORMATIONRUNNING HOURS COUNTER/OPERATING TIMEPHASE FAULT AND EARTH FAULT TRIP COUNTERSREMAINING OPERATING TIME BEFORE OVERLOAD TRIPPINGFAULT RECORDINGTRIP CONTEXT INFORMATIONEVENT RECORDINGSTARTING CURRENT AND TIMEWAITING TIME AFTER OVERLOAD TRIPPING |
| Logic input number | 6 |
| Input current | 3.1 MA AT 100 V7.5 MA AT 240 V |
| Current state 0 guaranteed | LOGIC INPUT: 0...40 V AND |
| Current state 1 guaranteed | LOGIC INPUT: 79...264 V AND >= 2 MA FOR 25 MS |
| maximum output switching frequency | 2 HZ |
| Load current | 5 A AT 250 V AC FOR LOGIC OUTPUT5 A AT 30 V DC FOR LOGIC OUTPUT |
| Permissible power | 480 VA (AC-15), IE = 2 A, 500000 CYCLES (OUTPUT)30 W (DC-13), IE = 1.25 A, 500000 CYCLES (OUTPUT) |
| maximum operating rate | 1800 CYC/H |
| Contacts type and composition | 1 NO + 1 NC FAULT SIGNAL3 NO |
| Metering type | IMBALANCE CURRENTTEMPERATUREAVERAGE CURRENT IAVGEARTH-FAULT CURRENTPHASE CURRENT I1, I2, I3 RMS |
| Measurement accuracy | 5...15 % EARTH FAULT CURRENT INTERNAL MEASUREMENT1 % VOLTAGE (100...830 V)3 % POWER FACTOR5 % EARTH FAULT CURRENT EXTERNAL MEASUREMENT+/- 30 MIN/YEAR INTERNAL CLOCK0,02 TEMPERATURE5 % ACTIVE AND REACTIVE POWER0,02 CURRENT |
| Overvoltage category | III |
| Connection pitch | 5.08 MM |
| Connections - terminals | CONTROL CIRCUIT: CONNECTOR 1 CABLE(S) 0.25…2.5 MM² (24 AWG...14 AWG) FLEXIBLE WITH CABLE ENDCONTROL CIRCUIT: CONNECTOR 1 CABLE(S) 0.2…2.5 MM² (24 AWG...14 AWG) FLEXIBLE WITHOUT CABLE ENDCONTROL CIRCUIT: CONNECTOR 1 CABLE(S) 0.25…2.5 MM² (24 AWG...14 AWG) FLEXIBLE WITHOUT CABLE ENDCONTROL CIRCUIT: CONNECTOR 1 CABLE(S) 0.2…2.5 MM² (24 AWG...14 AWG) SOLID WITHOUT CABLE ENDCONTROL CIRCUIT: CONNECTOR 2 CABLE(S) 0.2…1 MM² (24 AWG...14 AWG) FLEXIBLE WITH CABLE ENDCONTROL CIRCUIT: CONNECTOR 2 CABLE(S) 0.2…1.5 MM² (24 AWG...14 AWG) FLEXIBLE WITHOUT CABLE ENDCONTROL CIRCUIT: CONNECTOR 2 CABLE(S) 0.5…1.5 MM² (24 AWG...14 AWG) FLEXIBLE WITHOUT CABLE ENDCONTROL CIRCUIT: CONNECTOR 2 CABLE(S) 0.2…1 MM² (24 AWG...14 AWG) SOLID WITHOUT CABLE END |
| Tightening torque | CONTROL CIRCUIT: 0.5…0.6 N.M FLAT SCREWDRIVER 3 MM |
| Pollution degree | 3 |
| Electromagnetic compatibility | ELECTROSTATIC DISCHARGE, 3, 8 KV AIR, 6 KV CONTACT, CONFORMING TO EN/IEC 61000-4-2RADIATED RF FIELDS, 3, 10 V/M, CONFORMING TO EN/IEC 61000-4-3FAST TRANSIENTS IMMUNITY TEST (OTHER CIRCUITS), LEVEL 3, 2 KV, CONFORMING TO EN/IEC 61000-4-4FAST TRANSIENTS IMMUNITY TEST (ON SUPPLY AND RELAY OUTPUTS), LEVEL 4, 4 KV, CONFORMING TO EN/IEC 61000-4-4VOLTAGE DIPS AND INTERRUPTIONS IMMUNITY TEST, 70 %, 500 MS, CONFORMING TO EN/IEC 61000-4-11CONDUCTED RF DISTURBANCES, 10 V, CONFORMING TO EN/IEC 61000-4-6TEMPERATURE SENSOR: SURGES (SERIAL MODE), 0.5 KV, CONFORMING TO EN/IEC 61000-4-5TEMPERATURE SENSOR: SURGES (COMMON MODE), 1 KV, CONFORMING TO EN/IEC 61000-4-5CONTROL CIRCUIT: SURGES (SERIAL MODE), 1 KV, CONFORMING TO EN/IEC 61000-4-5COMMUNICATION: SURGES (COMMON MODE), 2 KV, CONFORMING TO EN/IEC 61000-4-5RELAY OUTPUTS AND SUPPLY: SURGES (SERIAL MODE), 2 KV, CONFORMING TO EN/IEC 61000-4-5RELAY OUTPUTS AND SUPPLY: SURGES (COMMON MODE), 4 KV, CONFORMING TO EN/IEC 61000-4-5CONTROL CIRCUIT: SURGES (COMMON MODE), 2 KV, CONFORMING TO EN/IEC 61000-4-5 |
| Width | 91 MM |
| Height | 61 MM |
| Depth | 122.5 MM |
| Net weight | 0.53 KG |
| Web services | WEB SERVER |
| Compatibility code | LTMR |
| Standards | EN 60947-4-1UL 508IEC 60947-4-1CSA C22.2 NO 14IACS E10 |
| Product certifications | CSADNVLROS (Lloyds register of shipping)RINAEACGLULATEXBVCCCRMRoSKERIABSNOMC-Tick |
| Protective treatment | 12 X 24 HOUR CYCLES CONFORMING TO EN/IEC 60068-2-3048 H CONFORMING TO EN/IEC 60070-2-11TH CONFORMING TO EN/IEC 60068 |
| Fire resistance | 650 °C CONFORMING TO EN/IEC 60695-2-12960 °C CONFORMING TO UL 94 |
| Ambient air temperature for operation | -20…60 °C |
| Ambient air temperature for storage | -40…80 °C |
| Mechanical robustness | VIBRATIONS MOUNTED ON SYMMETRICAL RAIL: 1 GN, 5...300 HZ CONFORMING TO EN/IEC 60068-2-6VIBRATIONS PLATE MOUNTED: 4 GN, 5...300 HZ CONFORMING TO EN/IEC 60068-2-6SHOCKS HALF SINE WAVE ACCELERATION: 15 GN FOR 11 MS CONFORMING TO EN/IEC 60068-2-27 |
| IP degree of protection | IP20 |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.0 CM |
| Package 1 Width | 10.0 CM |
| Package 1 Length | 13.5 CM |
| Package 1 Weight | 524.0 G |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 15.0 CM |
| Package 2 Width | 30.0 CM |
| Package 2 Length | 40.0 CM |
| Package 2 Weight | 5.626 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| Mercury free | ✓ |
| Halogen-free status | Halogen free plastic parts product |
| PVC free | Yes |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | End of Life Information (Download) |
| Recyclability potential, in % | 1 |
| Total lifecycle Carbon footprint | 31 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 18.473992778180737 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 18 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.06835105550439984 |
| Carbon footprint of the distribution phase [A4] | 0.1 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.20314653220802265 |
| Carbon footprint of the installation phase [A5] | 0.2 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 11.22355161504505 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 11 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 1.0160645096322527 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 1 kg CO2 eq. |
| SCIP Number | Fc01c523-9a07-4dfa-988f-c721d4816782 |
| REACh Regulation | Reference contains Substances of Very High Concern above the threshold (Download) |
| EU RoHS Directive | Compliant By Exemption (Download) |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Reviews
Overview
| Product Name | CONTROLLER DEVICENET 5 100A 115 230VAC |
|---|---|
| Tax Class | GST-18 |
| Country of Origin | China |
| Manufacturer | Schneider Electric |
| Range | TESYS |
| Product name | TESYS T |
| Device short name | LTMR |
| Product or component type | MOTOR CONTROLLER |
| Device application | EQUIPMENT MONITORING AND CONTROL |
| Measurement current | 5…100 A |
| [Us] rated supply voltage | 100...240 V AC 50/60 HZ |
| Current consumption | 8...62.8 MA |
| Supply voltage limits | 93.5…264 V AC |
| Communication port protocol | DEVICENET |
| Bus type | DEVICENET ISO 1198 INTERFACE, ADDRESSING 1...64, TRANSMISSION RATE 125...500 KBIT/S, TERMINAL BLOCK WITH 4 TWISTED SHIELDED PAIRS CABLE |
| [Ui] rated insulation voltage | 690 V CONFORMING TO EN/IEC 60947-1690 V CONFORMING TO CSA C22.2 NO 14690 V CONFORMING TO UL 508 |
| [Uimp] rated impulse withstand voltage | 4 KV SUPPLY, INPUTS AND OUTPUTS CONFORMING TO EN/IEC 60947-4-16 KV CURRENT OR VOLTAGE MEASUREMENT CIRCUIT CONFORMING TO EN/IEC 60947-4-10.8 KV COMMUNICATION CIRCUIT CONFORMING TO EN/IEC 60947-4-1 |
| Short-circuit withstand | 100 KA CONFORMING TO EN/IEC 60947-4-1 |
| Associated fuse rating | 4 A GG FOR OUTPUT0.5 A GG FOR CONTROL CIRCUIT |
| Protection type | PHASE FAILUREOVERLOAD (LONG TIME)LOAD FLUCTUATIONTHERMAL OVERLOAD PROTECTIONPOWER FACTOR VARIATIONOVERLOADLOCKED ROTORTHERMAL PROTECTIONEARTH-LEAKAGE PROTECTIONPHASE UNBALANCEREVERSE POLARITY PROTECTION |
| Network and machine diagnosis type | MOTOR CONTROL COMMAND RECORDINGTRIP HISTORY INFORMATIONRUNNING HOURS COUNTER/OPERATING TIMEPHASE FAULT AND EARTH FAULT TRIP COUNTERSREMAINING OPERATING TIME BEFORE OVERLOAD TRIPPINGFAULT RECORDINGTRIP CONTEXT INFORMATIONEVENT RECORDINGSTARTING CURRENT AND TIMEWAITING TIME AFTER OVERLOAD TRIPPING |
| Logic input number | 6 |
| Input current | 3.1 MA AT 100 V7.5 MA AT 240 V |
| Current state 0 guaranteed | LOGIC INPUT: 0...40 V AND |
| Current state 1 guaranteed | LOGIC INPUT: 79...264 V AND >= 2 MA FOR 25 MS |
| maximum output switching frequency | 2 HZ |
| Load current | 5 A AT 250 V AC FOR LOGIC OUTPUT5 A AT 30 V DC FOR LOGIC OUTPUT |
| Permissible power | 480 VA (AC-15), IE = 2 A, 500000 CYCLES (OUTPUT)30 W (DC-13), IE = 1.25 A, 500000 CYCLES (OUTPUT) |
| maximum operating rate | 1800 CYC/H |
| Contacts type and composition | 1 NO + 1 NC FAULT SIGNAL3 NO |
| Metering type | IMBALANCE CURRENTTEMPERATUREAVERAGE CURRENT IAVGEARTH-FAULT CURRENTPHASE CURRENT I1, I2, I3 RMS |
| Measurement accuracy | 5...15 % EARTH FAULT CURRENT INTERNAL MEASUREMENT1 % VOLTAGE (100...830 V)3 % POWER FACTOR5 % EARTH FAULT CURRENT EXTERNAL MEASUREMENT+/- 30 MIN/YEAR INTERNAL CLOCK0,02 TEMPERATURE5 % ACTIVE AND REACTIVE POWER0,02 CURRENT |
| Overvoltage category | III |
| Connection pitch | 5.08 MM |
| Connections - terminals | CONTROL CIRCUIT: CONNECTOR 1 CABLE(S) 0.25…2.5 MM² (24 AWG...14 AWG) FLEXIBLE WITH CABLE ENDCONTROL CIRCUIT: CONNECTOR 1 CABLE(S) 0.2…2.5 MM² (24 AWG...14 AWG) FLEXIBLE WITHOUT CABLE ENDCONTROL CIRCUIT: CONNECTOR 1 CABLE(S) 0.25…2.5 MM² (24 AWG...14 AWG) FLEXIBLE WITHOUT CABLE ENDCONTROL CIRCUIT: CONNECTOR 1 CABLE(S) 0.2…2.5 MM² (24 AWG...14 AWG) SOLID WITHOUT CABLE ENDCONTROL CIRCUIT: CONNECTOR 2 CABLE(S) 0.2…1 MM² (24 AWG...14 AWG) FLEXIBLE WITH CABLE ENDCONTROL CIRCUIT: CONNECTOR 2 CABLE(S) 0.2…1.5 MM² (24 AWG...14 AWG) FLEXIBLE WITHOUT CABLE ENDCONTROL CIRCUIT: CONNECTOR 2 CABLE(S) 0.5…1.5 MM² (24 AWG...14 AWG) FLEXIBLE WITHOUT CABLE ENDCONTROL CIRCUIT: CONNECTOR 2 CABLE(S) 0.2…1 MM² (24 AWG...14 AWG) SOLID WITHOUT CABLE END |
| Tightening torque | CONTROL CIRCUIT: 0.5…0.6 N.M FLAT SCREWDRIVER 3 MM |
| Pollution degree | 3 |
| Electromagnetic compatibility | ELECTROSTATIC DISCHARGE, 3, 8 KV AIR, 6 KV CONTACT, CONFORMING TO EN/IEC 61000-4-2RADIATED RF FIELDS, 3, 10 V/M, CONFORMING TO EN/IEC 61000-4-3FAST TRANSIENTS IMMUNITY TEST (OTHER CIRCUITS), LEVEL 3, 2 KV, CONFORMING TO EN/IEC 61000-4-4FAST TRANSIENTS IMMUNITY TEST (ON SUPPLY AND RELAY OUTPUTS), LEVEL 4, 4 KV, CONFORMING TO EN/IEC 61000-4-4VOLTAGE DIPS AND INTERRUPTIONS IMMUNITY TEST, 70 %, 500 MS, CONFORMING TO EN/IEC 61000-4-11CONDUCTED RF DISTURBANCES, 10 V, CONFORMING TO EN/IEC 61000-4-6TEMPERATURE SENSOR: SURGES (SERIAL MODE), 0.5 KV, CONFORMING TO EN/IEC 61000-4-5TEMPERATURE SENSOR: SURGES (COMMON MODE), 1 KV, CONFORMING TO EN/IEC 61000-4-5CONTROL CIRCUIT: SURGES (SERIAL MODE), 1 KV, CONFORMING TO EN/IEC 61000-4-5COMMUNICATION: SURGES (COMMON MODE), 2 KV, CONFORMING TO EN/IEC 61000-4-5RELAY OUTPUTS AND SUPPLY: SURGES (SERIAL MODE), 2 KV, CONFORMING TO EN/IEC 61000-4-5RELAY OUTPUTS AND SUPPLY: SURGES (COMMON MODE), 4 KV, CONFORMING TO EN/IEC 61000-4-5CONTROL CIRCUIT: SURGES (COMMON MODE), 2 KV, CONFORMING TO EN/IEC 61000-4-5 |
| Width | 91 MM |
| Height | 61 MM |
| Depth | 122.5 MM |
| Net weight | 0.53 KG |
| Web services | WEB SERVER |
| Compatibility code | LTMR |
| Standards | EN 60947-4-1UL 508IEC 60947-4-1CSA C22.2 NO 14IACS E10 |
| Product certifications | CSADNVLROS (Lloyds register of shipping)RINAEACGLULATEXBVCCCRMRoSKERIABSNOMC-Tick |
| Protective treatment | 12 X 24 HOUR CYCLES CONFORMING TO EN/IEC 60068-2-3048 H CONFORMING TO EN/IEC 60070-2-11TH CONFORMING TO EN/IEC 60068 |
| Fire resistance | 650 °C CONFORMING TO EN/IEC 60695-2-12960 °C CONFORMING TO UL 94 |
| Ambient air temperature for operation | -20…60 °C |
| Ambient air temperature for storage | -40…80 °C |
| Mechanical robustness | VIBRATIONS MOUNTED ON SYMMETRICAL RAIL: 1 GN, 5...300 HZ CONFORMING TO EN/IEC 60068-2-6VIBRATIONS PLATE MOUNTED: 4 GN, 5...300 HZ CONFORMING TO EN/IEC 60068-2-6SHOCKS HALF SINE WAVE ACCELERATION: 15 GN FOR 11 MS CONFORMING TO EN/IEC 60068-2-27 |
| IP degree of protection | IP20 |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.0 CM |
| Package 1 Width | 10.0 CM |
| Package 1 Length | 13.5 CM |
| Package 1 Weight | 524.0 G |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 15.0 CM |
| Package 2 Width | 30.0 CM |
| Package 2 Length | 40.0 CM |
| Package 2 Weight | 5.626 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| Mercury free | ✓ |
| Halogen-free status | Halogen free plastic parts product |
| PVC free | Yes |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | End of Life Information (Download) |
| Recyclability potential, in % | 1 |
| Total lifecycle Carbon footprint | 31 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 18.473992778180737 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 18 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.06835105550439984 |
| Carbon footprint of the distribution phase [A4] | 0.1 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.20314653220802265 |
| Carbon footprint of the installation phase [A5] | 0.2 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 11.22355161504505 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 11 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 1.0160645096322527 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 1 kg CO2 eq. |
| SCIP Number | Fc01c523-9a07-4dfa-988f-c721d4816782 |
| REACh Regulation | Reference contains Substances of Very High Concern above the threshold (Download) |
| EU RoHS Directive | Compliant By Exemption (Download) |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |