Weight (in Kg) 0.17725
Net weight 0.18 kg
Pole Contact Composition 4 NO
Product Or Component Type control relay
Mechanical Durability 10 Mcycles
Protective Treatment TC conforming to IEC 60068
Immunity to Microbreaks 2 ms
Insulation Resistance > 10 MOhm
Minimum Switching Current 5 mA
Minimum Switching Voltage 17 V
Contactor Application control circuit
Non Overlap Distance 0.5 mm
[IP] Degree of Protection IP2x
Connections Terminals screw clamp terminals 1 cable(s) 1.5-4 mm²solid
screw clamp terminals 2 cable(s) 1.5-4 mm²solid
screw clamp terminals 1 cable(s) 0.75-4 mm²flexible with cable end
screw clamp terminals 2 cable(s) 0.75-4 mm²flexible without cable end
screw clamp terminals 1 cable(s) 0.34-1.5 mm²flexible with cable end
screw clamp terminals 2 cable(s) 0.34-1.5 mm²flexible without cable end
Irms Rated Making Capacity 110 A conforming to IEC 60947
Ambient air temperature for operation -25-50 °C
Range of Product TeSys K control relay
Tightening Torque 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
1.3 N.m - on screw clamp terminals - with screwdriver Philips No 26 mm
1.3 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Standards BS 5424
IEC 60947
NF C 63-140
VDE 0660
Product Certifications UL
CSA
UKCA
Mechanical Robustness vibrations contactor open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
shocks contactor open: 10 Gn for 11 ms conforming to IEC 60068-2-27
shocks contactor closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
[Ith] Conventional Free Air Thermal Current 10 A (at 50 °C)
[ui] Rated Insulation Voltage 690 V conforming to IEC 60947
750 V conforming to VDE 0110 group C
690 V conforming to BS 5424
600 V conforming to CSA C22.2 No 14
Associated Fuse Rating 10 A gG conforming to IEC 60947
10 A gG conforming to VDE 0660
Mounting support plate
rail
Control Circuit Type AC at 50/60 Hz
Control Circuit Voltage Limits drop-out: 0.2...0.75 Uc (at <50 °C)
operational: 0.8...1.15 Uc (at <50 °C)
Heat Dissipation 1.3-1.3 W
Hold-In Power Consumption In VA 4.5-4.5 VA (at 20 °C)
Inrush Power In VA 30-30 VA (at 20 °C)
Maximum Operating Rate 10000 cyc/h
Operating Time 10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
Flame Retardance V1 conforming to UL 94
requirement 2 conforming to NF F 16-101
requirement 2 conforming to NF F 16-102
Device short name CA2K
Depth 57 mm
Ambient air temperature for storage -50-80 °C
Height 58 mm
width 45 mm
Utilisation category AC-15
DC-13
Operating altitude 2000 m without derating
Compatibility code CA2K
[Uc] Control Circuit Voltage 220...230 V AC 50/60 Hz
[Ue] Rated Operational Voltage <= 690 V <= 400 Hz