Schneider Electric TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NC aux. - 220...230 V AC coil

LC1K0901M7
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 220V 50/60Hz AC coil, 1NC built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Product Details

Weight (in Kg) 0.1775
auxiliary contacts type type instantaneous 1 NC
Pole Contact Composition 3 NO
Product Or Component Type contactor
Protective Treatment TC conforming to IEC 60068
TC conforming to DIN 50016
Insulation Resistance > 10 MOhm for signalling circuit
Minimum Switching Current 5 mA for signalling circuit
Minimum Switching Voltage 17 V for signalling circuit
Poles Description 3P
Average Impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Auxiliary Contact Composition 1 NC
Contactor Application motor control
resistive load
Non Overlap Distance 0.5 mm
Signalling Circuit Frequency <= 400 Hz
Irms Rated Making Capacity 110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Range of Product TeSys K
Product Certifications UKCA
Mechanical Robustness shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
[Ith] Conventional Free Air Thermal Current 20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Associated Fuse Rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Control Circuit Type AC at 50/60 Hz
Control Circuit Voltage Limits operational: 0.8...1.15 Uc (at <50 °C)
drop-out: 0.2...0.75 Uc (at <50 °C)
Heat Dissipation 1.3-1.3 W
Hold-In Power Consumption In VA 4.5-4.5 VA (at 20 °C)
Inrush Power In VA 30-30 VA (at 20 °C)
Maximum Operating Rate 3600 cyc/h
Motor Power Kw 2.2 kW at 220...230 V AC 50/60 Hz AC-3
4 kW at 380...415 V AC 50/60 Hz AC-3
4 kW at 440 V AC 50/60 Hz AC-3
4 kW at 480 V AC 50/60 Hz AC-3
4 kW at 500...600 V AC 50/60 Hz AC-3
4 kW at 660...690 V AC 50/60 Hz AC-3
2.2 kW at 400 V AC 50/60 Hz AC-4
Operating Time 10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
Rated Breaking Capacity 110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
Flame Retardance V1 conforming to UL 94
requirement 2 conforming to NF F 16-101
requirement 2 conforming to NF F 16-102
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Device short name LC1K
Overvoltage Category III
Utilisation category AC-4
AC-1
AC-3
Operating altitude 2000 m without derating
Compatibility code LC1K
Device Application control
[Uc] Control Circuit Voltage 220...230 V AC 50/60 Hz
Brand Schneider Electric

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review
You're reviewing: Schneider Electric TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NC aux. - 220...230 V AC coil
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.