LC1K1610M7

Schneider Electric TeSys K contactor - 3P - AC-3 <= 440 V 16 A - 1 NO aux. - 220...230 V AC coil

1/1
LC1K1610M7

Schneider Electric TeSys K contactor - 3P - AC-3 <= 440 V 16 A - 1 NO aux. - 220...230 V AC coil

In stock
SKU
LC1K1610M7
Rp ‎ 692.700
To View the best prices please sign in or register.
CHECK DELIVERY TIME & COD AVAILABILITY

Add to compare

No sellers found for this product.

Schneider Electric TeSys K contactor - 3P - AC-3 <= 440 V 16 A - 1 NO aux. - 220...230 V AC coil

Rp ‎ 692.700

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 16A/690V AC-3 (7.5kW@400V). It provides a 220V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Product details

  • Activity
    PPCTR
  • Weight (in Kg)
    0.1782
  • Net weight
    0.18 kg
  • auxiliary contacts type
    type instantaneous 1 NO
  • Pole Contact Composition
    3 NO
  • Product Or Component Type
    contactor
  • Mechanical Durability
    10 Mcycles
  • Protective Treatment
    TC conforming to IEC 60068
    TC conforming to DIN 50016
  • Insulation Resistance
    > 10 MOhm for signalling circuit
  • Minimum Switching Current
    5 mA for signalling circuit
  • Minimum Switching Voltage
    17 V for signalling circuit
  • Poles Description
    3P
  • Average Impedance
    3 mOhm - Ith 20 A 50 Hz for power circuit
  • Auxiliary Contact Composition
    1 NO
  • Contactor Application
    motor control
  • Non Overlap Distance
    0.5 mm
  • Signalling Circuit Frequency
    <= 400 Hz
  • [IP] Degree of Protection
    IP2x conforming to VDE 0106
  • Connections Terminals
    screw clamp terminals 1 cable(s) 1.5-4 mm²solid
    screw clamp terminals 1 cable(s) 0.75-4 mm²flexible without cable end
    screw clamp terminals 1 cable(s) 0.34-2.5 mm²flexible with cable end
    screw clamp terminals 2 cable(s) 1.5-4 mm²solid
    screw clamp terminals 2 cable(s) 0.75-4 mm²flexible without cable end
    screw clamp terminals 2 cable(s) 0.34-1.5 mm²flexible with cable end
  • [Uimp] Rated Impulse Wthstand Voltage
    8 kV
  • Irms Rated Making Capacity
    110 A AC for signalling circuit conforming to IEC 60947
    160 A AC for power circuit conforming to NF C 63-110
    160 A AC for power circuit conforming to IEC 60947
  • Ambient air temperature for operation
    -25-50 °C
  • Range of Product
    TeSys K
  • Tightening Torque
    1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2
    1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
    1.3 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
  • Standards
    EN/IEC 60947-4-1
    EN/IEC 60947-5-1
  • Product Certifications
    CB Scheme
    UKCA
  • Mechanical Robustness
    shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
    shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
    shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
    shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
    shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
    shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
    vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
    vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
  • [Ith] Conventional Free Air Thermal Current
    20 A (at 50 °C) for power circuit
    10 A (at 50 °C) for signalling circuit
  • [ui] Rated Insulation Voltage
    power circuit: 600 V conforming to UL 508
    power circuit: 690 V conforming to IEC 60947-4-1
    signalling circuit: 690 V conforming to IEC 60947-4-1
    signalling circuit: 690 V conforming to IEC 60947-5-1
    signalling circuit: 600 V conforming to UL 508
    power circuit: 600 V conforming to CSA C22.2 No 14
    signalling circuit: 600 V conforming to CSA C22.2 No 14
  • Associated Fuse Rating
    25 A gG at <= 440 V for power circuit
    25 A aM for power circuit
    10 A gG for signalling circuit conforming to IEC 60947
    10 A gG for signalling circuit conforming to VDE 0660
  • Mounting support
    plate
    rail
  • Control Circuit Type
    AC at 50/60 Hz
  • Control Circuit Voltage Limits
    operational: 0.8...1.15 Uc (at <50 °C)
    drop-out: 0.2...0.75 Uc (at <50 °C)
  • Electrical Durability
    1.3 Mcycles 16 A AC-3 at Ue <= 440 V
  • Heat Dissipation
    1.3-1.3 W
  • Hold-In Power Consumption In VA
    4.5-4.5 VA (at 20 °C)
  • Inrush Power In VA
    30-30 VA (at 20 °C)
  • Maximum Operating Rate
    3600 cyc/h
  • Motor Power Kw
    4 kW at 480 V AC 50/60 Hz
    4 kW at 500...600 V AC 50/60 Hz
    4 kW at 660...690 V AC 50/60 Hz
    5.5 kW at 440 V AC 50/60 Hz
    4 kW at 220...230 V AC 50/60 Hz
    7.5 kW at 380...415 V AC 50/60 Hz
  • Operating Time
    10...20 ms coil de-energisation and NO opening
    10...20 ms coil energisation and NO closing
  • Rated Breaking Capacity
    110 A at 440 V conforming to IEC 60947
    80 A at 500 V conforming to IEC 60947
    70 A at 660...690 V conforming to IEC 60947
  • [Icw] rated short-time withstand current
    115 A 50 °C - 1 s for power circuit
    105 A 50 °C - 5 s for power circuit
    100 A 50 °C - 10 s for power circuit
    75 A 50 °C - 30 s for power circuit
    55 A 50 °C - 1 min for power circuit
    50 A 50 °C - 3 min for power circuit
    25 A 50 °C - >= 15 min for power circuit
    80 A - 1 s for signalling circuit
    90 A - 500 ms for signalling circuit
    110 A - 100 ms for signalling circuit
  • Flame Retardance
    V1 conforming to UL 94
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
  • Device short name
    LC1K
  • Depth
    57 mm
  • Ambient air temperature for storage
    -50-80 °C
  • Height
    58 mm
  • Overvoltage Category
    III
  • width
    45 mm
  • Utilisation category
    AC-3
    AC-1
  • Operating altitude
    2000 m without derating
  • Compatibility code
    LC1K
  • Device Application
    control
  • [Uc] Control Circuit Voltage
    220...230 V AC 50/60 Hz
  • [Ue] Rated Operational Voltage
    power circuit: 690 V AC 50/60 Hz
    signalling circuit: 690 V AC 50/60 Hz
  • Brand
    Schneider Electric
more specification
less specification

Seller Information

Reviews

Write Your Own Review
You're reviewing:Schneider Electric TeSys K contactor - 3P - AC-3 <= 440 V 16 A - 1 NO aux. - 220...230 V AC coil
Your Rating

* Required Field