Schneider Electric TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 125 A - 220 V AC 50/60 Hz coil

LC1D80004M7
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Description

TeSys Deca contactor, 4-pole (4NO), for non-inductive load applications up to 125A/1000V AC-1. It provides a 220V 50/60Hz AC coil, power connection by screw terminals, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (96mm width), DIN-rail mounting or screw fixing. Without build-in auxiliary contacts, side and front mounting auxiliary contact blocks available (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Product Details

Weight (in Kg) 1.701
Net weight 1.76 kg
Pole Contact Composition 4 NO
Product Or Component Type contactor
Mechanical Durability 4 Mcycles
Protective Treatment TH conforming to IEC 60068-2-30
Poles Description 4P
Average Impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Contact Compatibility M1
Contactor Application resistive load
Protective Cover without
[IP] Degree of Protection IP20 front face conforming to IEC 60529
Connections Terminals control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
control circuit: screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end
control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
power circuit: connector 1 cable(s) 4-50 mm²flexible without cable end
power circuit: connector 2 cable(s) 4-25 mm²flexible without cable end
power circuit: connector 1 cable(s) 4-50 mm²flexible with cable end
power circuit: connector 2 cable(s) 4-16 mm²flexible with cable end
power circuit: connector 1 cable(s) 4-50 mm²solid without cable end
power circuit: connector 2 cable(s) 4-25 mm²solid without cable end
[Uimp] Rated Impulse Wthstand Voltage 8 kV conforming to IEC 60947
Irms Rated Making Capacity 1100 A at 440 V for power circuit conforming to IEC 60947
Ambient air temperature for operation -40-60 °C
60-70 °C with derating
Range of Product TeSys D
Tightening Torque control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm
power circuit: 12 N.m - on connector hexagonal screw head 4 mm
control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product Certifications DNV
LROS (Lloyds register of shipping)
GL
CSA
CCC
RINA
UL
GOST
BV
Mechanical Robustness vibrations contactor open: 2 Gn, 5...300 Hz
shocks contactor open: 8 Gn for 11 ms
vibrations contactor closed: 3 Gn, 5...300 Hz
shocks contactor closed: 10 Gn for 11 ms
[Ith] Conventional Free Air Thermal Current 125 A (at 60 °C) for power circuit
[ui] Rated Insulation Voltage power circuit: 600 V CSA certified
power circuit: 600 V UL certified
power circuit: 1000 V conforming to IEC 60947-4-1
Associated Fuse Rating 200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit
Mounting support rail
plate
Control Circuit Type AC at 50/60 Hz
Control Circuit Voltage Limits 0.85...1.1 Uc (-40-55 °C):operational AC 60 Hz
0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40-55 °C):operational AC 50 Hz
1...1.1 Uc (55-70 °C):operational AC 50/60 Hz
Electrical Durability 0.8 Mcycles 125 A AC-1 at Ue <= 440 V
Fire Resistance 850 °C conforming to IEC 60695-2-1
Heat Dissipation 6-10 W at 50/60 Hz
Hold-In Power Consumption In VA 26-26 VA 60 Hz cos phi 0.3 (at 20 °C)
26-26 VA 50 Hz cos phi 0.3 (at 20 °C)
Inrush Power In VA 245-245 VA 60 Hz cos phi 0.75 (at 20 °C)
245-245 VA 50 Hz cos phi 0.75 (at 20 °C)
Maximum Operating Rate 3600 cyc/h 60 °C
Operating Time 20...35 ms closing
6...20 ms opening
Power Dissipation Per Pole 12.5 W AC-1
Rated Breaking Capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 640 A 40 °C - 10 s for power circuit
990 A 40 °C - 1 s for power circuit
135 A 40 °C - 10 min for power circuit
320 A 40 °C - 1 min for power circuit
Flame Retardance V1 conforming to UL 94
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Climatic Withstand conforming to IACS E10
Coil Technology without built-in suppressor module
Device short name LC1D
Depth 125 mm
Ambient air temperature for storage -60-80 °C
Height 127 mm
Overvoltage Category III
width 96 mm
Pollution degree 3
Utilisation category AC-1
Operating altitude 0...3000 m
Compatibility code LC1D
[Uc] Control Circuit Voltage 220 V AC 50/60 Hz
[Ue] Rated Operational Voltage power circuit: <= 300 V DC 25...400 Hz
power circuit: <= 690 V AC
Brand Schneider Electric

Seller Information

Documents

Reviews

Write Your Own Review
You're reviewing: Schneider Electric TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 125 A - 220 V AC 50/60 Hz coil
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.