LC1D80008M7

Schneider Electric TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 125 A 220 V AC 50/60 Hz coil

1/1
LC1D80008M7

Schneider Electric TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 125 A 220 V AC 50/60 Hz coil

In stock
SKU
LC1D80008M7
Rp ‎ 5.558.900
To View the best prices please sign in or register.
CHECK DELIVERY TIME & COD AVAILABILITY

Add to compare

No sellers found for this product.

Schneider Electric TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 125 A 220 V AC 50/60 Hz coil

Rp ‎ 5.558.900

Description

TeSys Deca contactor, 4-pole (2NO+2NC), for non-inductive load applications up to 125A/1000V AC-1. It provides a 220V 50/60Hz AC coil, power connection by screw terminals, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (96mm width), DIN-rail mounting or screw fixing. Without build-in auxiliary contacts, side and front mounting auxiliary contact blocks available (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Product details

  • Activity
    PPCTR
  • Weight (in Kg)
    1.807
  • Net weight
    1.84 kg
  • Pole Contact Composition
    2 NO + 2 NC
  • Product Or Component Type
    contactor
  • Mechanical Durability
    4 Mcycles
  • Protective Treatment
    TH conforming to IEC 60068-2-30
  • Poles Description
    4P
  • Average Impedance
    0.8 mOhm - Ith 125 A 50 Hz for power circuit
  • Contact Compatibility
    M1
  • Contactor Application
    resistive load
  • Protective Cover
    without
  • [IP] Degree of Protection
    IP20 front face conforming to IEC 60529
  • Connections Terminals
    control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
    control circuit: screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end
    control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
    control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
    control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
    control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
    power circuit: connector 1 cable(s) 4-50 mm²flexible without cable end
    power circuit: connector 2 cable(s) 4-25 mm²flexible without cable end
    power circuit: connector 1 cable(s) 4-50 mm²flexible with cable end
    power circuit: connector 2 cable(s) 4-16 mm²flexible with cable end
    power circuit: connector 1 cable(s) 4-50 mm²solid without cable end
    power circuit: connector 2 cable(s) 4-25 mm²solid without cable end
  • [Uimp] Rated Impulse Wthstand Voltage
    8 kV conforming to IEC 60947
  • Irms Rated Making Capacity
    1100 A at 440 V for power circuit conforming to IEC 60947
  • Ambient air temperature for operation
    -40-60 °C
    60-70 °C with derating
  • Range of Product
    TeSys D
  • Tightening Torque
    control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
    control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
    power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm
    power circuit: 12 N.m - on connector hexagonal screw head 4 mm
    control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
  • Standards
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 60947-4-1
    UL 60947-5-1
    CSA C22.2 No 60947-4-1
    CSA C22.2 No 60947-5-1
    GB/T 14048.4
  • Product Certifications
    UL
    CSA
    CCC
    EAC
    UKCA
    CB
    EU-RO-MR by DNV-GL
  • Mechanical Robustness
    vibrations contactor open: 2 Gn, 5...300 Hz
    shocks contactor open: 8 Gn for 11 ms
    vibrations contactor closed: 3 Gn, 5...300 Hz
    shocks contactor closed: 10 Gn for 11 ms
  • [Ith] Conventional Free Air Thermal Current
    125 A (at 60 °C) for power circuit
  • [ui] Rated Insulation Voltage
    power circuit: 600 V CSA certified
    power circuit: 600 V UL certified
    power circuit: 1000 V conforming to IEC 60947-4-1
  • Associated Fuse Rating
    200 A gG at <= 690 V coordination type 1 for power circuit
    160 A gG at <= 690 V coordination type 2 for power circuit
  • Mounting support
    plate
    rail
  • Control Circuit Type
    AC at 50/60 Hz
  • Control Circuit Voltage Limits
    0.85...1.1 Uc (-40-55 °C):operational AC 60 Hz
    0.3...0.6 Uc (-40-55 °C):drop-out AC 50/60 Hz
    0.8...1.1 Uc (-40-55 °C):operational AC 50 Hz
  • Electrical Durability
    0.8 Mcycles 125 A AC-1 at Ue <= 440 V
  • Fire Resistance
    850 °C conforming to IEC 60695-2-1
  • Heat Dissipation
    6-10 W at 50/60 Hz
  • Hold-In Power Consumption In VA
    26-26 VA 60 Hz cos phi 0.3 (at 20 °C)
    26-26 VA 50 Hz cos phi 0.3 (at 20 °C)
  • Inrush Power In VA
    245-245 VA 60 Hz cos phi 0.75 (at 20 °C)
    245-245 VA 50 Hz cos phi 0.75 (at 20 °C)
  • Maximum Operating Rate
    3600 cyc/h 60 °C
  • Operating Time
    20...35 ms closing
    6...20 ms opening
  • Power Dissipation Per Pole
    12.5 W AC-1
  • Rated Breaking Capacity
    1100 A at 440 V for power circuit conforming to IEC 60947
  • [Icw] rated short-time withstand current
    640 A 40 °C - 10 s for power circuit
    990 A 40 °C - 1 s for power circuit
    135 A 40 °C - 10 min for power circuit
    320 A 40 °C - 1 min for power circuit
  • Flame Retardance
    V1 conforming to UL 94
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
  • Climatic Withstand
    conforming to IACS E10
  • Coil Technology
    without built-in suppressor module
  • Device short name
    LC1D
  • Depth
    140 mm
  • Ambient air temperature for storage
    -60-80 °C
  • Height
    127 mm
  • Overvoltage Category
    III
  • width
    96 mm
  • Pollution degree
    3
  • Utilisation category
    AC-1
  • Operating altitude
    0...3000 m
  • Compatibility code
    LC1D
  • [Uc] Control Circuit Voltage
    220 V AC 50/60 Hz
  • [Ue] Rated Operational Voltage
    power circuit: <= 1000 V AC 25...400 Hz
  • Brand
    Schneider Electric
more specification
less specification

Seller Information

Reviews

Write Your Own Review
You're reviewing:Schneider Electric TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 125 A 220 V AC 50/60 Hz coil
Your Rating

* Required Field