Weight (in Kg) |
2.49 |
Net weight |
2.5 kg |
auxiliary contacts type |
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
Pole Contact Composition |
3 NO |
Product Or Component Type |
contactor |
Mechanical Durability |
8 Mcycles |
Protective Treatment |
TH conforming to IEC 60068-2-30 |
Insulation Resistance |
> 10 MOhm for signalling circuit |
Minimum Switching Current |
5 mA for signalling circuit |
Minimum Switching Voltage |
17 V for signalling circuit |
Poles Description |
3P |
Average Impedance |
0.6 mOhm - Ith 200 A 50 Hz for power circuit |
Auxiliary Contact Composition |
1 NO + 1 NC |
Contact Compatibility |
M13 |
Contactor Application |
motor control resistive load |
Motor Starter Type |
direct on-line contactor |
Protective Cover |
with |
Signalling Circuit Frequency |
25...400 Hz |
[IP] Degree of Protection |
IP20 front face conforming to IEC 60529 |
Connections Terminals |
control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end control circuit: screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end control circuit: screw clamp terminals 1 cable(s) 1-2.5 mm²flexible without cable end control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible without cable end control circuit: screw clamp terminals 1 cable(s) 1-2.5 mm²solid without cable end control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²solid without cable end power circuit: connector 1 cable(s) 10-120 mm²flexible without cable end power circuit: connector 2 cable(s) 10-50 mm²flexible without cable end power circuit: connector 1 cable(s) 10-120 mm²flexible with cable end power circuit: connector 2 cable(s) 10-50 mm²flexible with cable end power circuit: connector 1 cable(s) 10-120 mm²solid without cable end power circuit: connector 2 cable(s) 10-50 mm²solid without cable end |
[Uimp] Rated Impulse Wthstand Voltage |
8 kV conforming to IEC 60947 |
Irms Rated Making Capacity |
140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1660 A at 440 V for power circuit conforming to IEC 60947 |
power_range |
30-50 kW at 200-240 V 3 phases 55-100 kW at 380-440 V 3 phases 55-100 kW at 480-500 V 3 phases |
Ambient air temperature for operation |
-40-60 °C 60-70 °C with derating |
Range of Product |
TeSys D |
Tightening Torque |
control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 power circuit: 12 N.m - on connector hexagonal screw head 4 mm control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
Standards |
CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
Product Certifications |
CCC LROS (Lloyds register of shipping) GL GOST RINA CSA BV UL DNV UKCA |
Mechanical Robustness |
vibrations contactor open: 2 Gn, 5...300 Hz vibrations contactor closed: 4 Gn, 5...300 Hz shocks contactor closed: 15 Gn for 11 ms shocks contactor open: 6 Gn for 11 ms |
[Ith] Conventional Free Air Thermal Current |
200 A (at 60 °C) for power circuit |
[ui] Rated Insulation Voltage |
power circuit: 600 V CSA certified power circuit: 600 V UL certified power circuit: 1000 V conforming to IEC 60947-4-1 signalling circuit: 690 V conforming to IEC 60947-1 signalling circuit: 600 V CSA certified signalling circuit: 600 V UL certified |
Associated Fuse Rating |
10 A gG for signalling circuit conforming to IEC 60947-5-1 315 A gG at <= 690 V coordination type 1 for power circuit 250 A gG at <= 690 V coordination type 2 for power circuit |
Mounting support |
rail plate |
Control Circuit Type |
AC at 50/60 Hz |
Control Circuit Voltage Limits |
0.3...0.5 Uc (-40-70 °C):drop-out AC 50/60 Hz 0.8...1.15 Uc (-40-55 °C):operational AC 50/60 Hz 1...1.15 Uc (55-70 °C):operational AC 50/60 Hz |
Electrical Durability |
0.85 Mcycles 150 A AC-3 at Ue <= 440 V 1 Mcycles 200 A AC-1 at Ue <= 440 V |
Fire Resistance |
850 °C conforming to IEC 60695-2-1 |
Heat Dissipation |
3-4.5 W at 50/60 Hz |
Hold-In Power Consumption In VA |
2-18 VA 60 Hz cos phi 0.9 (at 20 °C) 2-18 VA 50 Hz cos phi 0.9 (at 20 °C) |
Inrush Power In VA |
280-350 VA 60 Hz cos phi 0.9 (at 20 °C) 280-350 VA 50 Hz cos phi 0.9 (at 20 °C) |
Maximum Operating Rate |
1200 cyc/h 60 °C |
Motor Power Kw |
40 kW at 220...230 V AC 50/60 Hz (AC-3) 75 kW at 380...400 V AC 50/60 Hz (AC-3) 80 kW at 415...440 V AC 50/60 Hz (AC-3) 90 kW at 500 V AC 50/60 Hz (AC-3) 100 kW at 660...690 V AC 50/60 Hz (AC-3) 75 kW at 1000 V AC 50/60 Hz (AC-3) 22 kW at 400 V AC 50/60 Hz (AC-4) |
Operating Time |
20...35 ms closing 40...75 ms opening |
Power Dissipation Per Pole |
24 W AC-1 13.5 W AC-3 |
Rated Breaking Capacity |
1400 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current |
250 A 40 °C - 10 min for power circuit 580 A 40 °C - 1 min for power circuit 1200 A 40 °C - 10 s for power circuit 1400 A 40 °C - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit |
Flame Retardance |
V1 conforming to UL 94 |
Contactor Coil Voltage |
220 V AC standard |
Safety Reliability Level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Climatic Withstand |
conforming to IACS E10 |
Coil Technology |
built-in bidirectional peak limiting diode suppressor |
Motor Power Hp |
40 hp at 200/208 V AC 50/60 Hz for 3 phases motors 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
Device short name |
LC1D |
Depth |
136 mm |
Ambient air temperature for storage |
-60-80 °C |
Height |
158 mm |
Overvoltage Category |
III |
width |
120 mm |
Pollution degree |
3 |
Utilisation category |
AC-3 AC-4 AC-1 |
Operating altitude |
0...3000 m |
Non-Overlap Time |
1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Compatibility code |
LC1D |
[Uc] Control Circuit Voltage |
220 V AC 50/60 Hz |
[Ue] Rated Operational Voltage |
power circuit: <= 1000 V AC 25...400 Hz power circuit: <= 300 V DC |
Brand |
Schneider Electric |