calcPageSize())"
/>
Further offers for this product
Incl. Tax
No sellers found for this product.
Incl. Tax
Motor circuit breaker, TeSys GV4, 3P, 12.5 A, Icu 50 kA, magnetic, EverLink terminals
- Description
- Specifications
- Environmental Data
- Documents
- Reviews
Description
Overview
| Poles Description | 3P |
|---|---|
| Brand | Schneider Electric |
| Height | 10.9 |
| Length | 22.1 |
| Width | 21.3 |
| Range | TESYS DECA |
| Range of product | TESYS GV4 |
| Device short name | GV4L |
| Product name | TESYS GV4 |
| Product or component type | MOTOR CIRCUIT BREAKER |
| Device application | MOTOR PROTECTION |
| Trip unit technology | MAGNETICELECTRONIC |
| Poles description | 3P |
| Utilisation category | CATEGORY A CONFORMING TO IEC 60947-2AC-3 CONFORMING TO IEC 60947-4-1 |
| Operating position | ANY POSITION |
| Motor power kW | 3 KW AT 400...415 V AC 50/60 HZ3 KW AT 500 V AC 50/60 HZ4 KW AT 500 V AC 50/60 HZ5.5 KW AT 660...690 V AC 50/60 HZ7.5 KW AT 660...690 V AC 50/60 HZ4 KW AT 400...415 V AC 50/60 HZ5.5 KW AT 400...415 V AC 50/60 HZ5.5 KW AT 500 V AC 50/60 HZ7.5 KW AT 500 V AC 50/60 HZ9 KW AT 660...690 V AC 50/60 HZ11 KW AT 660...690 V AC 50/60 HZ |
| Breaking capacity | 100 KA ICU AT 220...240 V AC 50/60 HZ CONFORMING TO IEC 60947-250 KA ICU AT 380...415 V AC 50/60 HZ CONFORMING TO IEC 60947-250 KA ICU AT 440 V AC 50/60 HZ CONFORMING TO IEC 60947-215 KA ICU AT 525 V AC 50/60 HZ CONFORMING TO IEC 60947-28 KA ICU AT 660...690 V AC 50/60 HZ CONFORMING TO IEC 60947-225 KA ICU AT 500 V AC 50/60 HZ CONFORMING TO IEC 60947-2 |
| Control type | ROTARY HANDLE |
| [In] rated current | 12.5 A |
| Magnetic tripping current | 75…175 A |
| [Ue] rated operational voltage | 690 V AC 50/60 HZ CONFORMING TO IEC 60947-2 |
| [Ui] rated insulation voltage | 800 V AC 50/60 HZ CONFORMING TO IEC 60947-2 |
| [Ith] conventional free air thermal current | 115 A CONFORMING TO IEC 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 8 KV CONFORMING TO IEC 60947-2 |
| Power dissipation per pole | 6.1 W |
| Mechanical durability | 40000 CYCLES |
| Electrical durability | 40000 CYCLES FOR AC-3 AT 440 V IN/240000 CYCLES FOR AC-3 AT 440 V IN |
| maximum operating rate | 25 CYC/H |
| Rated duty | CONTINUOUS CONFORMING TO IEC 60947-4-1 |
| Connections - terminals | EVERLINK BTR SCREW CONNECTORS (TOP) 1 CABLE(S) 1.5…70 MM² - SOLIDEVERLINK BTR SCREW CONNECTORS (TOP) 1 CABLE(S) 1.5…50 MM² - FLEXIBLEEVERLINK BTR SCREW CONNECTORS (BOTTOM) 1 CABLE(S) 2.5…95 MM² - SOLIDEVERLINK BTR SCREW CONNECTORS (BOTTOM) 1 CABLE(S) 2.5…70 MM² - FLEXIBLE |
| Tightening torque | 9 N.M FOR CABLE 16…95 MM²5 N.M FOR CABLE 1.5…10 MM² |
| Mechanical robustness | VIBRATIONS: +/- 1 MM 2...13.2 HZ CONFORMING TO IEC 60068-2-6VIBRATIONS: 0.7 GN 13.2...100 HZ CONFORMING TO IEC 60068-2-6SHOCKS: 15 GN 11 MS CONFORMING TO IEC 60068-2-27 |
| Height | 155 MM |
| Width | 81 MM |
| Depth | 165 MM |
| Net weight | 1.65 KG |
| Colour | GREY (RAL 7016) |
| Suitability for isolation | YES CONFORMING TO IEC 60947-1 |
| Standards | EN/IEC 60947-4-1EN/IEC 60947-2 |
| Product certifications | IECCCCEACEU-RO MR |
| Climatic withstand | CONFORMING TO IACS E10 |
| IK degree of protection | IK07 CONFORMING TO IEC 62262 |
| Pollution degree | 3 |
| IP degree of protection | IP40 CONFORMING TO IEC 60529 |
| Ambient air temperature for storage | -50…85 °C |
| Fire resistance | 960 °C CONFORMING TO IEC 60695-2-11 |
| Operating altitude | 5000 M |
| Ambient air temperature for operation | -25…70 °C |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 10.900 CM |
| Package 1 Width | 21.300 CM |
| Package 1 Length | 22.100 CM |
| Package 1 Weight | 1.826 KG |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 3 |
| Package 2 Height | 30.000 CM |
| Package 2 Width | 30.000 CM |
| Package 2 Length | 40.000 CM |
| Package 2 Weight | 9.500 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| REACh free of SVHC | ✓ |
| Toxic heavy metal free | ✓ |
| Mercury free | ✓ |
| RoHS exemption information | Yes (Download) |
| Halogen-free status | Halogen free plastic parts product |
| PVC free | Yes |
| REACh Regulation | REACh Declaration (Download) |
| EU RoHS Directive | EU RoHS Declaration (Download) |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | End of Life Information (Download) |
| Recyclability potential, in % | 49 |
| Total lifecycle Carbon footprint | 114 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 10.521728565354675 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 11 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.44494421315757204 |
| Carbon footprint of the distribution phase [A4] | 0.4 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.39650886217586284 |
| Carbon footprint of the installation phase [A5] | 0.4 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 98.55743478260871 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 99 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 3.5854239204368135 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 4 kg CO2 eq. |
| SCIP Number | 1b259a2c-3a3c-401a-acdd-f0837efd4018 |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Reviews
Description
Overview
| Poles Description | 3P |
|---|---|
| Brand | Schneider Electric |
| Height | 10.9 |
| Length | 22.1 |
| Width | 21.3 |
| Range | TESYS DECA |
| Range of product | TESYS GV4 |
| Device short name | GV4L |
| Product name | TESYS GV4 |
| Product or component type | MOTOR CIRCUIT BREAKER |
| Device application | MOTOR PROTECTION |
| Trip unit technology | MAGNETICELECTRONIC |
| Poles description | 3P |
| Utilisation category | CATEGORY A CONFORMING TO IEC 60947-2AC-3 CONFORMING TO IEC 60947-4-1 |
| Operating position | ANY POSITION |
| Motor power kW | 3 KW AT 400...415 V AC 50/60 HZ3 KW AT 500 V AC 50/60 HZ4 KW AT 500 V AC 50/60 HZ5.5 KW AT 660...690 V AC 50/60 HZ7.5 KW AT 660...690 V AC 50/60 HZ4 KW AT 400...415 V AC 50/60 HZ5.5 KW AT 400...415 V AC 50/60 HZ5.5 KW AT 500 V AC 50/60 HZ7.5 KW AT 500 V AC 50/60 HZ9 KW AT 660...690 V AC 50/60 HZ11 KW AT 660...690 V AC 50/60 HZ |
| Breaking capacity | 100 KA ICU AT 220...240 V AC 50/60 HZ CONFORMING TO IEC 60947-250 KA ICU AT 380...415 V AC 50/60 HZ CONFORMING TO IEC 60947-250 KA ICU AT 440 V AC 50/60 HZ CONFORMING TO IEC 60947-215 KA ICU AT 525 V AC 50/60 HZ CONFORMING TO IEC 60947-28 KA ICU AT 660...690 V AC 50/60 HZ CONFORMING TO IEC 60947-225 KA ICU AT 500 V AC 50/60 HZ CONFORMING TO IEC 60947-2 |
| Control type | ROTARY HANDLE |
| [In] rated current | 12.5 A |
| Magnetic tripping current | 75…175 A |
| [Ue] rated operational voltage | 690 V AC 50/60 HZ CONFORMING TO IEC 60947-2 |
| [Ui] rated insulation voltage | 800 V AC 50/60 HZ CONFORMING TO IEC 60947-2 |
| [Ith] conventional free air thermal current | 115 A CONFORMING TO IEC 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 8 KV CONFORMING TO IEC 60947-2 |
| Power dissipation per pole | 6.1 W |
| Mechanical durability | 40000 CYCLES |
| Electrical durability | 40000 CYCLES FOR AC-3 AT 440 V IN/240000 CYCLES FOR AC-3 AT 440 V IN |
| maximum operating rate | 25 CYC/H |
| Rated duty | CONTINUOUS CONFORMING TO IEC 60947-4-1 |
| Connections - terminals | EVERLINK BTR SCREW CONNECTORS (TOP) 1 CABLE(S) 1.5…70 MM² - SOLIDEVERLINK BTR SCREW CONNECTORS (TOP) 1 CABLE(S) 1.5…50 MM² - FLEXIBLEEVERLINK BTR SCREW CONNECTORS (BOTTOM) 1 CABLE(S) 2.5…95 MM² - SOLIDEVERLINK BTR SCREW CONNECTORS (BOTTOM) 1 CABLE(S) 2.5…70 MM² - FLEXIBLE |
| Tightening torque | 9 N.M FOR CABLE 16…95 MM²5 N.M FOR CABLE 1.5…10 MM² |
| Mechanical robustness | VIBRATIONS: +/- 1 MM 2...13.2 HZ CONFORMING TO IEC 60068-2-6VIBRATIONS: 0.7 GN 13.2...100 HZ CONFORMING TO IEC 60068-2-6SHOCKS: 15 GN 11 MS CONFORMING TO IEC 60068-2-27 |
| Height | 155 MM |
| Width | 81 MM |
| Depth | 165 MM |
| Net weight | 1.65 KG |
| Colour | GREY (RAL 7016) |
| Suitability for isolation | YES CONFORMING TO IEC 60947-1 |
| Standards | EN/IEC 60947-4-1EN/IEC 60947-2 |
| Product certifications | IECCCCEACEU-RO MR |
| Climatic withstand | CONFORMING TO IACS E10 |
| IK degree of protection | IK07 CONFORMING TO IEC 62262 |
| Pollution degree | 3 |
| IP degree of protection | IP40 CONFORMING TO IEC 60529 |
| Ambient air temperature for storage | -50…85 °C |
| Fire resistance | 960 °C CONFORMING TO IEC 60695-2-11 |
| Operating altitude | 5000 M |
| Ambient air temperature for operation | -25…70 °C |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 10.900 CM |
| Package 1 Width | 21.300 CM |
| Package 1 Length | 22.100 CM |
| Package 1 Weight | 1.826 KG |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 3 |
| Package 2 Height | 30.000 CM |
| Package 2 Width | 30.000 CM |
| Package 2 Length | 40.000 CM |
| Package 2 Weight | 9.500 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| REACh free of SVHC | ✓ |
| Toxic heavy metal free | ✓ |
| Mercury free | ✓ |
| RoHS exemption information | Yes (Download) |
| Halogen-free status | Halogen free plastic parts product |
| PVC free | Yes |
| REACh Regulation | REACh Declaration (Download) |
| EU RoHS Directive | EU RoHS Declaration (Download) |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | End of Life Information (Download) |
| Recyclability potential, in % | 49 |
| Total lifecycle Carbon footprint | 114 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 10.521728565354675 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 11 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.44494421315757204 |
| Carbon footprint of the distribution phase [A4] | 0.4 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.39650886217586284 |
| Carbon footprint of the installation phase [A5] | 0.4 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 98.55743478260871 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 99 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 3.5854239204368135 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 4 kg CO2 eq. |
| SCIP Number | 1b259a2c-3a3c-401a-acdd-f0837efd4018 |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |