Schneider Electric Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals

GV4PE115B
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Description

Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals

Product Details

Net weight 1.45 kg
Operating Position any position
Product or Component Type motor circuit breaker
Breaking Capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2, 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2, 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 14 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947, 18 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947, 35 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947, 35 kA at 240 V AC 50/60 Hz conforming to UL 60947
Control Type toggle
Colour grey (RAL 7016)
Trip Unit Technology electronic,thermal-magnetic
Breaking Capacity 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2,25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2,20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2,10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2,35 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947,35 kA at 240 V AC 50/60 Hz conforming to UL 60947,18 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947,14 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
Mechanical Durability 40000 cycles
[ue] Rated Operational Voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
Poles Description 3P
IK Degree Of Protection IK07 conforming to IEC 62262
Phase Failure Sensitivity yes conforming to IEC 60947-4-1
Direct Connector without
Magnetic Tripping Current 1955-1955 A
Range of Product TeSys GV4
Standards CSA C22.2 No 60947-4-1,UL 60947-4-1,EN/IEC 60947-4-1,EN/IEC 60947-2
Mechanical Robustness vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6,vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6,shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Electrical Durability 10000 cycles for AC-3 at 440 V In/2,5000 cycles for AC-3 at 440 V In
Power Dissipation Per Pole 4.6 W
Rated Duty continuous conforming to IEC 60947-4-1
Device short name GV4PE
Depth 116 mm
Height 155 mm
width 81 mm
Pollution degree 3
Utilisation category category A conforming to IEC 60947-2,AC-3 conforming to IEC 60947-4-1
Operating altitude 5000 m
Device Application motor protection
Range TeSys Deca
IP degree of protection IP40 conforming to IEC 60529
Brand Schneider Electric

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review
You're reviewing: Schneider Electric Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.