TeSys island direct starter, 3 poles, 38A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 38A and motors up to 18,5kW@400V / 20hp@480V. It provides motor protection functions including thermal overload (setting 0.76-38A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Product Details
Weight (in Kg) | 0.77 |
---|---|
Net weight | 0.718 kg |
Product Or Component Type | motor starter |
Mounting Mode | horizontal and vertical (35 mm symmetrical DIN rail) |
Mechanical Durability | 30 Mcycles |
Protective Treatment | TC |
Reset | remotely or automatically |
Poles Description | 3P (3 NO) |
Average Impedance | 2 mOhm - Ith 40 A 50 Hz |
Motor Starter Type | direct on line |
Thermal Protection Adjustment Range | 0.76-38 A |
[IP] Degree of Protection | IP20 |
Connections Terminals | screw-clamp terminals 1 cable(s) 1.5-10 mm² (AWG 16...AWG 8) rigid screw-clamp terminals 2 cable(s) 1.5-10 mm² (AWG 16...AWG 8) rigid screw-clamp terminals 1 cable(s) 2.5-10 mm² (AWG 14...AWG 8) flexible without cable end screw-clamp terminals 2 cable(s) 2.5-10 mm² (AWG 14...AWG 8) flexible without cable end screw-clamp terminals 1 cable(s) 1.5-10 mm² (AWG 16...AWG 10) flexible with cable end screw-clamp terminals 2 cable(s) 1.5-6 mm² (AWG 16...AWG 10) flexible with cable end |
[Uimp] Rated Impulse Wthstand Voltage | 6 kV conforming to IEC 60947-1 |
Irms Rated Making Capacity | 550 A at 440 V conforming to IEC 60947 |
protection_type | thermal overload protection motor overheat overcurrent undercurrent jam long start stall rapid cycle lockout phase sequence rapid restart lockout phase loss phase reversal phase unbalance ground current |
Ambient air temperature for operation | -10-50 °C without derating 50-60 °C with current derating |
Tightening Torque | 2.5-2.5 N.m - with screwdriver flat Ø 6 mm 2.5-2.5 N.m - with screwdriver Philips No 3 |
Standards | EN/IEC 60947-1 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 |
Product Certifications | CCC EAC UL CSA |
[Ith] Conventional Free Air Thermal Current | 40 A (at 50 °C) |
[ui] Rated Insulation Voltage | 690 V conforming to IEC 60947-4-1 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1 |
Electrical Durability | 1.4 Mcycles 38 A AC-3 at Ue 440 V 2 Mcycles 40 A AC-1 at Ue 440 V |
Fire Resistance | 960 °C conforming to UL 94 850 °C conforming to IEC 60695-2-1 650 °C conforming to IEC 60695-2-12 |
Maximum Operating Rate | 3600 cyc/mn AC-3 |
Motor Power Kw | 9 kW at 230 V 50 Hz (AC-3) 18.5 kW at 380...415 V 50 Hz (AC-3) 18.5 kW at 440 V 50 Hz (AC-3) 18.5 kW at 500 V 50 Hz (AC-3) 18.5 kW at 690 V 50 Hz (AC-3) |
Operating Time | < 100 ms closing < 30 ms opening |
Power Dissipation Per Pole | 2.9 W AC-3 - Ith 38 A 3.2 W AC-1 - Ith 40 A |
Rated Breaking Capacity | 550 A at 440 V conforming to IEC 60947 |
[Icw] rated short-time withstand current | 430 A 40 °C - 1 s 310 A 40 °C - 10 s 150 A 40 °C - 1 min 60 A 40 °C - 10 min |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Motor Power Hp | 2 hp at 120 V AC 60 Hz for 1 phase motors 5 hp at 240 V AC 60 Hz for 1 phase motors 10 hp at 208 V AC 60 Hz for 3 phases motors 10 hp at 240 V AC 60 Hz for 3 phases motors 20 hp at 480 V AC 60 Hz for 3 phases motors 25 hp at 600 V AC 60 Hz for 3 phases motors |
Product Compatibility | TPRBC bus coupler TPRVM voltage interface module |
Local Signalling | 1 LED (green/red) for DS (device status) 1 LED (green/red) for LS (load status) |
Electromagnetic Compatibility | electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4 surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5 conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6 |
Thermal Overload Class | class 5…30 |
Current Consumption | 160 mA contactor sealed 160 mA contactor closing |
Shock Resistance | 15 gn (duration = 11 ms) conforming to IEC 60068-2-27 |
Function Available | upstream voltage presence detection electrical line and load protection power and energy monitoring when connected with TPRVM voltage module |
Metering Type | time device ON time device switch ON number of faults number of switching cycles number of device power cycles average current Iavg average voltage Vavg max current Imax max voltage Vmax active and reactive power with voltage module active and reactive energy with voltage module true power factor with voltage module |
Device Presentation | direct starter connected to an automation controller through a bus coupler operational only when connected to a bus coupler |
Device short name | TPRST |
Depth | 115 mm |
Ambient air temperature for storage | -25-70 °C |
Height | 121 mm |
Overvoltage Category | III for Ue <= 480 V II for Ue <= 690 V |
width | 45 mm |
Pollution degree | 2 |
Utilisation category | AC-1 AC-2 AC-3 AC-4 |
Operating altitude | 0...2000 m without derating |
Vibration Resistance | 1.5 mm peak to peak (f= 3-13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6 |
Relative humidity | 5-95 % |
Power Dissipation in w | 11.8 W at Ie AC-3 |
[Uc] Control Circuit Voltage | 24 V DC supplied by the bus coupler |
[Ue] Rated Operational Voltage | <= 480 V AC 47...63 Hz for overvoltage cat. III <= 690 V AC 47...63 Hz for overvoltage cat. II |
Brand | Schneider Electric |