TeSys island direct starter, 3 poles, 9A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 9A and motors up to 4kW@400V / 5hp@480V. It provides motor protection functions including thermal overload (setting 0.18-9A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Product Details
Weight (in Kg) | 0.709 |
---|---|
Net weight | 0.656 kg |
Product Or Component Type | motor starter |
Mounting Mode | horizontal and vertical (35 mm symmetrical DIN rail) |
Mechanical Durability | 30 Mcycles |
Protective Treatment | TC |
Reset | remotely or automatically |
Poles Description | 3P (3 NO) |
Average Impedance | 2.5 mOhm - Ith 15 A 50 Hz |
Motor Starter Type | direct on line |
Thermal Protection Adjustment Range | 0.18-9 A |
[IP] Degree of Protection | IP20 |
Connections Terminals | screw-clamp terminals 1 cable(s) 1-4 mm² (AWG 16...AWG 12) rigid screw-clamp terminals 2 cable(s) 1-4 mm² (AWG 16...AWG 12) rigid screw-clamp terminals 1 cable(s) 1.5-4 mm² (AWG 16...AWG 12) flexible without cable end screw-clamp terminals 2 cable(s) 1.5-4 mm² (AWG 16...AWG 12) flexible without cable end screw-clamp terminals 1 cable(s) 1-4 mm² (AWG 16...AWG 12) flexible with cable end screw-clamp terminals 2 cable(s) 1-2.5 mm² (AWG 16...AWG 14) flexible with cable end |
[Uimp] Rated Impulse Wthstand Voltage | 6 kV conforming to IEC 60947-1 |
Irms Rated Making Capacity | 250 A at 440 V conforming to IEC 60947 |
protection_type | thermal overload protection motor overheat overcurrent undercurrent jam long start stall rapid cycle lockout phase sequence rapid restart lockout phase reversal phase loss phase unbalance ground current |
Ambient air temperature for operation | -10-50 °C without derating 50-60 °C with current derating |
Tightening Torque | 1.7-1.7 N.m - with screwdriver flat Ø 6 mm 1.7-1.7 N.m - with screwdriver Philips No 2 |
Standards | EN/IEC 60947-1 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 |
Product Certifications | EAC CSA CCC UL |
[Ith] Conventional Free Air Thermal Current | 15 A (at 50 °C) |
[ui] Rated Insulation Voltage | 690 V conforming to IEC 60947-4-1 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1 |
Electrical Durability | 2 Mcycles 9 A AC-3 at Ue 440 V 1.2 Mcycles 15 A AC-1 at Ue 440 V |
Fire Resistance | 960 °C conforming to UL 94 850 °C conforming to IEC 60695-2-1 650 °C conforming to IEC 60695-2-12 |
Maximum Operating Rate | 3600 cyc/mn AC-3 |
Motor Power Kw | 2.2 kW at 230 V 50 Hz (AC-3) 4 kW at 380...415 V 50 Hz (AC-3) 4 kW at 440 V 50 Hz (AC-3) 5.5 kW at 500 V 50 Hz (AC-3) 5.5 kW at 690 V 50 Hz (AC-3) |
Operating Time | < 100 ms closing < 30 ms opening |
Power Dissipation Per Pole | 0.2 W AC-3 - Ith 9 A 0.56 W AC-1 - Ith 15 A |
Rated Breaking Capacity | 250 A at 440 V conforming to IEC 60947 |
[Icw] rated short-time withstand current | 210 A 40 °C - 1 s 105 A 40 °C - 10 s 61 A 40 °C - 1 min 30 A 40 °C - 10 min |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Motor Power Hp | 0.33 hp at 120 V AC 60 Hz for 1 phase motors 1 hp at 240 V AC 60 Hz for 1 phase motors 2 hp at 208 V AC 60 Hz for 3 phases motors 2 hp at 240 V AC 60 Hz for 3 phases motors 5 hp at 480 V AC 60 Hz for 3 phases motors 7.5 hp at 600 V AC 60 Hz for 3 phases motors |
Product Compatibility | TPRBC bus coupler TPRVM voltage interface module |
Local Signalling | 1 LED (green/red) for DS (device status) 1 LED (green/red) for LS (load status) |
Electromagnetic Compatibility | electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4 surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5 conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6 |
Thermal Overload Class | class 5…30 |
Current Consumption | 160 mA contactor sealed 160 mA contactor closing |
Shock Resistance | 15 gn (duration = 11 ms) conforming to IEC 60068-2-27 |
Function Available | upstream voltage presence detection electrical line and load protection power and energy monitoring when connected with TPRVM voltage module |
Metering Type | time device ON time device switch ON number of faults number of switching cycles number of device power cycles average current Iavg average voltage Vavg max current Imax max voltage Vmax active and reactive power with voltage module active and reactive energy with voltage module true power factor with voltage module |
Device Presentation | direct starter connected to an automation controller through a bus coupler operational only when connected to a bus coupler |
Device short name | TPRST |
Depth | 115 mm |
Ambient air temperature for storage | -25-70 °C |
Height | 116 mm |
Overvoltage Category | III |
width | 45 mm |
Pollution degree | 2 |
Utilisation category | AC-1 AC-2 AC-3 AC-4 |
Operating altitude | 0...2000 m without derating |
Vibration Resistance | 1.5 mm peak to peak (f= 3-13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6 |
Relative humidity | 5-95 % |
Power Dissipation in w | 3.5 W at Ie AC-3 |
[Uc] Control Circuit Voltage | 24 V DC supplied by the bus coupler |
[Ue] Rated Operational Voltage | <= 690 V AC 47...63 Hz |
Brand | Schneider Electric |