Schneider Electric Direct online starter, TeSys island, 15A AC-1, 9A AC-3, 4kW / 5hp

TPRST009
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Description

TeSys island direct starter, 3 poles, 9A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 9A and motors up to 4kW@400V / 5hp@480V. It provides motor protection functions including thermal overload (setting 0.18-9A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Product Details

Weight (in Kg) 0.709
Net weight 0.656 kg
Product Or Component Type motor starter
Mounting Mode horizontal and vertical (35 mm symmetrical DIN rail)
Mechanical Durability 30 Mcycles
Protective Treatment TC
Reset remotely or automatically
Poles Description 3P (3 NO)
Average Impedance 2.5 mOhm - Ith 15 A 50 Hz
Motor Starter Type direct on line
Thermal Protection Adjustment Range 0.18-9 A
[IP] Degree of Protection IP20
Connections Terminals screw-clamp terminals 1 cable(s) 1-4 mm² (AWG 16...AWG 12) rigid
screw-clamp terminals 2 cable(s) 1-4 mm² (AWG 16...AWG 12) rigid
screw-clamp terminals 1 cable(s) 1.5-4 mm² (AWG 16...AWG 12) flexible without cable end
screw-clamp terminals 2 cable(s) 1.5-4 mm² (AWG 16...AWG 12) flexible without cable end
screw-clamp terminals 1 cable(s) 1-4 mm² (AWG 16...AWG 12) flexible with cable end
screw-clamp terminals 2 cable(s) 1-2.5 mm² (AWG 16...AWG 14) flexible with cable end
[Uimp] Rated Impulse Wthstand Voltage 6 kV conforming to IEC 60947-1
Irms Rated Making Capacity 250 A at 440 V conforming to IEC 60947
protection_type thermal overload protection
motor overheat
overcurrent
undercurrent
jam
long start
stall
rapid cycle lockout
phase sequence
rapid restart lockout
phase reversal
phase loss
phase unbalance
ground current
Ambient air temperature for operation -10-50 °C without derating
50-60 °C with current derating
Tightening Torque 1.7-1.7 N.m - with screwdriver flat Ø 6 mm
1.7-1.7 N.m - with screwdriver Philips No 2
Standards EN/IEC 60947-1
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product Certifications EAC
CSA
CCC
UL
[Ith] Conventional Free Air Thermal Current 15 A (at 50 °C)
[ui] Rated Insulation Voltage 690 V conforming to IEC 60947-4-1
600 V conforming to UL 60947-4-1
600 V conforming to CSA C22.2 No 60947-4-1
Electrical Durability 2 Mcycles 9 A AC-3 at Ue 440 V
1.2 Mcycles 15 A AC-1 at Ue 440 V
Fire Resistance 960 °C conforming to UL 94
850 °C conforming to IEC 60695-2-1
650 °C conforming to IEC 60695-2-12
Maximum Operating Rate 3600 cyc/mn AC-3
Motor Power Kw 2.2 kW at 230 V 50 Hz (AC-3)
4 kW at 380...415 V 50 Hz (AC-3)
4 kW at 440 V 50 Hz (AC-3)
5.5 kW at 500 V 50 Hz (AC-3)
5.5 kW at 690 V 50 Hz (AC-3)
Operating Time < 100 ms closing
< 30 ms opening
Power Dissipation Per Pole 0.2 W AC-3 - Ith 9 A
0.56 W AC-1 - Ith 15 A
Rated Breaking Capacity 250 A at 440 V conforming to IEC 60947
[Icw] rated short-time withstand current 210 A 40 °C - 1 s
105 A 40 °C - 10 s
61 A 40 °C - 1 min
30 A 40 °C - 10 min
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Motor Power Hp 0.33 hp at 120 V AC 60 Hz for 1 phase motors
1 hp at 240 V AC 60 Hz for 1 phase motors
2 hp at 208 V AC 60 Hz for 3 phases motors
2 hp at 240 V AC 60 Hz for 3 phases motors
5 hp at 480 V AC 60 Hz for 3 phases motors
7.5 hp at 600 V AC 60 Hz for 3 phases motors
Product Compatibility TPRBC bus coupler
TPRVM voltage interface module
Local Signalling 1 LED (green/red) for DS (device status)
1 LED (green/red) for LS (load status)
Electromagnetic Compatibility electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3
fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4
surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5
surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5
conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6
Thermal Overload Class class 5…30
Current Consumption 160 mA contactor sealed
160 mA contactor closing
Shock Resistance 15 gn (duration = 11 ms) conforming to IEC 60068-2-27
Function Available upstream voltage presence detection
electrical line and load protection
power and energy monitoring when connected with TPRVM voltage module
Metering Type time device ON
time device switch ON
number of faults
number of switching cycles
number of device power cycles
average current Iavg
average voltage Vavg
max current Imax
max voltage Vmax
active and reactive power with voltage module
active and reactive energy with voltage module
true power factor with voltage module
Device Presentation direct starter connected to an automation controller through a bus coupler
operational only when connected to a bus coupler
Device short name TPRST
Depth 115 mm
Ambient air temperature for storage -25-70 °C
Height 116 mm
Overvoltage Category III
width 45 mm
Pollution degree 2
Utilisation category AC-1
AC-2
AC-3
AC-4
Operating altitude 0...2000 m without derating
Vibration Resistance 1.5 mm peak to peak (f= 3-13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6
Relative humidity 5-95 %
Power Dissipation in w 3.5 W at Ie AC-3
[Uc] Control Circuit Voltage 24 V DC supplied by the bus coupler
[Ue] Rated Operational Voltage <= 690 V AC 47...63 Hz
Brand Schneider Electric

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review
You're reviewing: Schneider Electric Direct online starter, TeSys island, 15A AC-1, 9A AC-3, 4kW / 5hp
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.