calcPageSize())"
/>
- Description
- Specifications
- Reviews
Description
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 24V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Overview
| [ie] Rated Operational Current | 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit |
|---|---|
| [uc] Control Circuit Voltage | 24 V AC 50/60 Hz |
| Auxiliary Contacts Type | type instantaneous 1 NO |
| Compatibility Code | LC1K |
| Device Application | control |
| Device Short Name | LC1K |
| Flame Retardance | V1 conforming to UL 94 |
| Mechanical Robustness | shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 |
| Overvoltage Category | III |
| Poles Description | 3P |
| Product Certifications | CSA |
| Product Name | TeSys K |
| Product or Component Type | contactor |
| Range | TeSys |
| Range of Product | TeSys K |
| Utilisation Category | AC-3 |
| [ith] Conventional Free Air Thermal Current | 20 A (at 50 °C) for power circuit |
| Associated Fuse Rating | 25 A gG at <= 440 V for power circuit |
| Auxiliary Contact Composition | 1 NO |
| Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| Contactor Application | motor control |
| Control Circuit Type | AC at 50/60 Hz |
| Control Circuit Voltage Limits | operational: 0.8...1.15 Uc (at <50 °C) |
| Heat Dissipation | 1.3-1.3 W |
| Hold-in Power Consumption in Va | 4.5-4.5 VA (at 20 °C) |
| Inrush Power in Va | 30-30 VA (at 20 °C) |
| Insulation Resistance | > 10 MOhm for signalling circuit |
| Irms Rated Making Capacity | 110 A AC for power circuit conforming to NF C 63-110 |
| Maximum Operating Rate | 3600 cyc/h |
| Minimum Switching Current | 5 mA for signalling circuit |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Motor Power Kw | 2.2 kW at 220...230 V AC 50/60 Hz AC-3 |
| Non Overlap Distance | 0.5 mm |
| Operating Altitude | 2000 m without derating |
| Operating Time | 10...20 ms coil de-energisation and NO opening |
| Pole Contact Composition | 3 NO |
| Protective Treatment | TC conforming to IEC 60068 |
| Rated Breaking Capacity | 110 A at 415 V conforming to IEC 60947 |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 |
| Signalling Circuit Frequency | <= 400 Hz |
Reviews
Description
TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 24V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Overview
| [ie] Rated Operational Current | 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit |
|---|---|
| [uc] Control Circuit Voltage | 24 V AC 50/60 Hz |
| Auxiliary Contacts Type | type instantaneous 1 NO |
| Compatibility Code | LC1K |
| Device Application | control |
| Device Short Name | LC1K |
| Flame Retardance | V1 conforming to UL 94 |
| Mechanical Robustness | shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 |
| Overvoltage Category | III |
| Poles Description | 3P |
| Product Certifications | CSA |
| Product Name | TeSys K |
| Product or Component Type | contactor |
| Range | TeSys |
| Range of Product | TeSys K |
| Utilisation Category | AC-3 |
| [ith] Conventional Free Air Thermal Current | 20 A (at 50 °C) for power circuit |
| Associated Fuse Rating | 25 A gG at <= 440 V for power circuit |
| Auxiliary Contact Composition | 1 NO |
| Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| Contactor Application | motor control |
| Control Circuit Type | AC at 50/60 Hz |
| Control Circuit Voltage Limits | operational: 0.8...1.15 Uc (at <50 °C) |
| Heat Dissipation | 1.3-1.3 W |
| Hold-in Power Consumption in Va | 4.5-4.5 VA (at 20 °C) |
| Inrush Power in Va | 30-30 VA (at 20 °C) |
| Insulation Resistance | > 10 MOhm for signalling circuit |
| Irms Rated Making Capacity | 110 A AC for power circuit conforming to NF C 63-110 |
| Maximum Operating Rate | 3600 cyc/h |
| Minimum Switching Current | 5 mA for signalling circuit |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Motor Power Kw | 2.2 kW at 220...230 V AC 50/60 Hz AC-3 |
| Non Overlap Distance | 0.5 mm |
| Operating Altitude | 2000 m without derating |
| Operating Time | 10...20 ms coil de-energisation and NO opening |
| Pole Contact Composition | 3 NO |
| Protective Treatment | TC conforming to IEC 60068 |
| Rated Breaking Capacity | 110 A at 415 V conforming to IEC 60947 |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 |
| Signalling Circuit Frequency | <= 400 Hz |