calcPageSize())"
/>
- Description
- Specifications
- Reviews
Description
TeSys D contactor, 3 poles (3NO), for motor control applications up to 50A/440V AC-3/3e (22kW@400V). It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by EverLink BTR screw connectors, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Overview
| [ie] Rated Operational Current | 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
|---|---|
| [uc] Control Circuit Voltage | 220 V AC 50/60 Hz , 220 V AC 50/60 Hz , 220 V AC 50/60 Hz |
| [ue] Rated Operational Voltage | power circuit: <= 690 V AC 25...400 Hz |
| [ui] Rated Insulation Voltage | power circuit: 600 V CSA certified |
| [uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947 |
| Ambient Air Temperature for Operation | -40-60 °C |
| Ambient Air Temperature for Storage | -60-80 °C |
| Auxiliary Contacts Type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 |
| Climatic Withstand | conforming to IACS E10 |
| Compatibility Code | LC1D |
| Depth | 120 mm |
| Device Short Name | LC1D |
| Electrical Durability | 1.45 Mcycles 50 A AC-3 at Ue <= 440 V |
| Fire Resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame Retardance | V1 conforming to UL 94 |
| Height | 6.2 cm |
| Ip Degree of Protection | IP20 front face conforming to IEC 60529 |
| Mechanical Durability | 6 Mcycles |
| Mechanical Robustness | vibrations contactor open: 2 Gn, 5...300 Hz |
| Mounting Support | plate |
| Net Weight | 0.855 kg |
| Overvoltage Category | III |
| Poles Description | 3P |
| Pollution Degree | 3 |
| Power Range | 7-11 kW at 200-240 V 3 phases |
| Product Certifications | RINA |
| Product Name | TeSys D |
| Product or Component Type | contactor |
| Range | TeSys |
| Range of Product | TeSys D |
| Standards | CSA C22.2 No 14 |
| Tightening Torque | control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver flat Ø 6 mm |
| Utilisation Category | AC-4 |
| Width | 13.5 cm |
| [icw] Rated Short-time Withstand Current | 400 A 40 °C - 10 s for power circuit |
| Connections - Terminals | control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end |
| [ith] Conventional Free Air Thermal Current | 10 A (at 60 °C) for signalling circuit |
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| Average Impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
| Coil Technology | without built-in suppressor module |
| Contact Compatibility | M2 |
| Contactor Application | resistive load|motor control |
| Contactor Coil Voltage | 220 V AC standard |
| Control Circuit Type | AC at 50/60 Hz |
| Control Circuit Voltage Limits | 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz |
| Heat Dissipation | 4-5 W at 50/60 Hz |
| Hold-in Power Consumption in Va | 13-13 VA 60 Hz cos phi 0.3 (at 20 °C) |
| Inrush Power in Va | 140-140 VA 60 Hz cos phi 0.75 (at 20 °C) |
| Insulation Resistance | > 10 MOhm for signalling circuit |
| Irms Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 |
| Maximum Operating Rate | 3600 cyc/h 60 °C |
| Minimum Switching Current | 5 mA for signalling circuit |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Motor Power Hp | 3 hp at 115 V AC 50/60 Hz for 1 phase motors |
| Motor Power Kw | 15 kW at 220...230 V AC 50/60 Hz (AC-3) |
| Motor Starter Type | direct on-line contactor |
| Non-overlap Time | 1.5 ms on de-energisation between NC and NO contact |
| Operating Altitude | 0...3000 m |
| Operating Time | 4...19 ms opening |
| Pole Contact Composition | 3 NO |
| Power Dissipation Per Pole | 3.7 W AC-3 |
| Protective Cover | with |
| Protective Treatment | TH conforming to IEC 60068-2-30 |
| Rated Breaking Capacity | 900 A at 440 V for power circuit conforming to IEC 60947 |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 |
| Signalling Circuit Frequency | 25...400 Hz |
| [Ue] rated operational voltage | power circuit: <= 690 V AC 25...400 Hz , power circuit: <= 690 V AC 25...400 Hz , power circuit: <= 690 V AC 25...400 Hz , power circuit: <= 690 V AC 25...400 Hz , power circuit: <= 300 V DC , power circuit: <= 300 V DC , power circuit: <= 300 V DC |
| Utilisation category | AC-4|AC-1|AC-3|AC-3e |
| Range | TeSys|TeSys Deca |
| Range of Product | TeSys Deca |
| [ie] Rated Operational Current | 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| Length | 15.2 cm |
| Activity code | PPCTR |
| Poles description | 3P |
| Product Hover Image | no_selection |
Reviews
Description
TeSys D contactor, 3 poles (3NO), for motor control applications up to 50A/440V AC-3/3e (22kW@400V). It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by EverLink BTR screw connectors, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Overview
| [ie] Rated Operational Current | 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
|---|---|
| [uc] Control Circuit Voltage | 220 V AC 50/60 Hz , 220 V AC 50/60 Hz , 220 V AC 50/60 Hz |
| [ue] Rated Operational Voltage | power circuit: <= 690 V AC 25...400 Hz |
| [ui] Rated Insulation Voltage | power circuit: 600 V CSA certified |
| [uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947 |
| Ambient Air Temperature for Operation | -40-60 °C |
| Ambient Air Temperature for Storage | -60-80 °C |
| Auxiliary Contacts Type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 |
| Climatic Withstand | conforming to IACS E10 |
| Compatibility Code | LC1D |
| Depth | 120 mm |
| Device Short Name | LC1D |
| Electrical Durability | 1.45 Mcycles 50 A AC-3 at Ue <= 440 V |
| Fire Resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame Retardance | V1 conforming to UL 94 |
| Height | 6.2 cm |
| Ip Degree of Protection | IP20 front face conforming to IEC 60529 |
| Mechanical Durability | 6 Mcycles |
| Mechanical Robustness | vibrations contactor open: 2 Gn, 5...300 Hz |
| Mounting Support | plate |
| Net Weight | 0.855 kg |
| Overvoltage Category | III |
| Poles Description | 3P |
| Pollution Degree | 3 |
| Power Range | 7-11 kW at 200-240 V 3 phases |
| Product Certifications | RINA |
| Product Name | TeSys D |
| Product or Component Type | contactor |
| Range | TeSys |
| Range of Product | TeSys D |
| Standards | CSA C22.2 No 14 |
| Tightening Torque | control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver flat Ø 6 mm |
| Utilisation Category | AC-4 |
| Width | 13.5 cm |
| [icw] Rated Short-time Withstand Current | 400 A 40 °C - 10 s for power circuit |
| Connections - Terminals | control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end |
| [ith] Conventional Free Air Thermal Current | 10 A (at 60 °C) for signalling circuit |
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| Average Impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
| Coil Technology | without built-in suppressor module |
| Contact Compatibility | M2 |
| Contactor Application | resistive load|motor control |
| Contactor Coil Voltage | 220 V AC standard |
| Control Circuit Type | AC at 50/60 Hz |
| Control Circuit Voltage Limits | 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz |
| Heat Dissipation | 4-5 W at 50/60 Hz |
| Hold-in Power Consumption in Va | 13-13 VA 60 Hz cos phi 0.3 (at 20 °C) |
| Inrush Power in Va | 140-140 VA 60 Hz cos phi 0.75 (at 20 °C) |
| Insulation Resistance | > 10 MOhm for signalling circuit |
| Irms Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 |
| Maximum Operating Rate | 3600 cyc/h 60 °C |
| Minimum Switching Current | 5 mA for signalling circuit |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Motor Power Hp | 3 hp at 115 V AC 50/60 Hz for 1 phase motors |
| Motor Power Kw | 15 kW at 220...230 V AC 50/60 Hz (AC-3) |
| Motor Starter Type | direct on-line contactor |
| Non-overlap Time | 1.5 ms on de-energisation between NC and NO contact |
| Operating Altitude | 0...3000 m |
| Operating Time | 4...19 ms opening |
| Pole Contact Composition | 3 NO |
| Power Dissipation Per Pole | 3.7 W AC-3 |
| Protective Cover | with |
| Protective Treatment | TH conforming to IEC 60068-2-30 |
| Rated Breaking Capacity | 900 A at 440 V for power circuit conforming to IEC 60947 |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 |
| Signalling Circuit Frequency | 25...400 Hz |
| [Ue] rated operational voltage | power circuit: <= 690 V AC 25...400 Hz , power circuit: <= 690 V AC 25...400 Hz , power circuit: <= 690 V AC 25...400 Hz , power circuit: <= 690 V AC 25...400 Hz , power circuit: <= 300 V DC , power circuit: <= 300 V DC , power circuit: <= 300 V DC |
| Utilisation category | AC-4|AC-1|AC-3|AC-3e |
| Range | TeSys|TeSys Deca |
| Range of Product | TeSys Deca |
| [ie] Rated Operational Current | 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit , 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit , 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| Length | 15.2 cm |
| Activity code | PPCTR |
| Poles description | 3P |
| Product Hover Image | no_selection |