residual current protection relay, Vigirex RH21M, 30 mA or 300 mA, 220/240 VAC 50/60 Hz, DIN rail mounting
Excl. Tax
Excl. Tax
All Sellers
Seller | Price | Delivery | Shipping Cost | ||
---|---|---|---|---|---|
View Seller Profile
B2B Network
|
|
Shipping Cost
|
No sellers found for this product.
residual current protection relay, Vigirex RH21M, 30 mA or 300 mA, 220/240 VAC 50/60 Hz, DIN rail mounting
Excl. Tax
Excl. Tax
Description
VigiPacT RH21M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 220/240VAC 50/60Hz. The current sensitivity is selectable with 2 thresholds 30 mA and 300 mA. The time delay is instantaneous 0.06s. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.
Product Details
Activity | PPCCB |
---|---|
[uimp] Rated Impulse Withstand Voltage | 8 kV |
[us] Rated Supply Voltage | 220...240 V AC 50/60 Hz 55...110 % |
Ambient Air Temperature for Operation | -35-70 °C |
Ambient Air Temperature for Storage | -55-85 °C |
Compatibility Code | RH21M |
Depth | 74 mm |
Device Short Name | RH21M |
Electromagnetic Compatibility | conducted and radiated emissions: , B, conforming to CISPR 11 |
Height | 81 mm |
Ik Degree of Protection | IK07 conforming to EN 50102 |
Ip Degree of Protection | IP40 on front face: conforming to EN/IEC 60529 |
Mechanical Robustness | fire resistance conforming to IEC 60695-2-1 |
Minimum Load | 10 mA at 12 V |
Mounting Support | DIN rail |
Net Weight | 0.3 kg |
Overvoltage Category | IV |
Product or Component Type | residual current protection relay |
Range | VigiPacT |
Range Compatibility | TOA earth leakage current sensor |
Tightening Torque | auxiliary power supply: 0.6-0.6 N.m top |
Width | 54 mm |
Wire Stripping Length | auxiliary power supply: 7 mm for top connection |
9 Mm Pitches | 6 |
Connections - Terminals | auxiliary power supply: terminal block cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12 |
[ithe] Conventional Enclosed Thermal Current | 8:00 AM |
Earth Leakage Current | 0.03-0.03 A |
Earthing System | IT |
Electrical Shock Protection Class | class II |
Monitoring | electronics (continuous) |
Network Rated Voltage | 1000-1000 V - AC at 50/60 Hz (maximum) |
Power Consumption in Va | 4 VA |
Relay Application | protection relay |
Reset | manual reset |
Residual Earth-leakage Sensitity Adjustment Type | adjustable 2 settings |
Residual Earth-leakage Time Delay Adjustment Type | instantaneous for 0.03-0.03 A |
Tamperproof of Settings | protected by sealable cover |
Test Function | local |
Type of Measurement | earth fault current internal measurement, range: 80...100 % |
Type of Setting | selector |
Earth-leakage Protection Class | type A |
Pollution Degree | 3 conforming to IEC 60664-1 |
Relative Humidity | 95-95 % at 55-55 °C |