Easypact CVS - CVS630F TM500D circuit breaker - 3P/3d

LV563305
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Out of stock

Description

EasyPact CVS630F is a 3 poles 3d fixed circuit breaker with a high level of performance and cost-saving functionality. It is an optimal choice for small and medium-sized buildings protection applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 440VAC 50/60Hz. This product embeds a 500A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection. This 3 poles version (140mm x 255mm x 110mm) comes with a variety of optional functions and accessories. EasyPact CVS630F is compliant with international standards (IEC 60947, CCC, EAC). It can be installed in class II insulation switchboards as it is a class II front face device (IEC 60664-1).

Product Details

Activity PPCCB
[ics] Rated Service Breaking Capacity 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
[uimp] Rated Impulse Withstand Voltage 8 kV conforming to EN/IEC 60947-2
Ambient Air Temperature for Operation -25-70 °C
Ambient Air Temperature for Storage -50-85 °C
Breaking Capacity Code F
Compatibility Code CVS630
Connection Pitch 45 mm
Contact Position Indicator yes
Control Type toggle
Depth 110 mm
Device Application distribution
Device Short Name CVS630F
Electrical Durability 4000 cycles 415 V In conforming to IEC 60947-2
Height 255 mm
Ip Degree of Protection IP40
Long Time Delay Adjustment Type fixed
Mechanical Durability 15000 cycles
Mounting Mode fixed
Mounting Support backplate
Net Weight 5.2 kg
Network Frequency 50/60 Hz
Network Type AC
Product Certifications IEC
Product Name EasyPact CVS
Product or Component Type circuit breaker
Protection Type short-circuit protection (magnetic)
Range EasyPact
Standards EN 60947-2
Width 140 mm
Connections - Terminals screw connection
Instantaneous Pick-up Adjustment Range 5...10 x In
Instantaneous Pick-up Adjustment Type Ii adjustable
Long Time Pick-up Adjustment Range 0.7...1 x In
Long Time Pick-up Adjustment Type Ir adjustable
Downside Connection front
Earth-leakage Protection without
Electrical Shock Protection Class class II
Thermal Protection Adjustment Range 350-500 A
Upside Connection front
Poles Description 3P
[in] Rated Current 500 A at 40 °C
Breaking Capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Pollution Degree 3 conforming to IEC 60664-1
Protected Poles Description 3D
Trip Unit Name TM-D
Trip Unit Rating 500-500 A at 40 °C
Trip Unit Technology thermal-magnetic
Utilisation Category category A