TeSys GC - modular contactor - 25 A - 1 NO - coil 220...240 V AC

GC2510M5
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Product Details

Activity PPCTR
Pincode Group default
Part Number GC2510M5
[Ith] conventional free air thermal current 25 A (at 50 °C) for power circuit
[Uc] control circuit voltage 220...240 V AC 50 Hz
[Ui] rated insulation voltage 500 V conforming to IEC 61095, 500 V conforming to VDE 0110
[Uimp] rated impulse withstand voltage 4 kV
ambient air temperature for storage -40-70 °C
associated fuse rating 25 A gL at <= 440 V for power circuit
average impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit
colour white
compatibility code modular standard contactor
connections - terminals control circuit: screw clamp terminals 1 cable(s) 2.5-2.5 mm²flexible without cable end, power circuit: screw clamp terminals 2 cable(s) 1.5-1.5 mm²flexible with cable end, power circuit: screw clamp terminals 1 cable(s) 6-6 mm²solid without cable end, power circuit: screw clamp terminals 2 cable(s) 4-4 mm²solid without cable end, control circuit: screw clamp terminals 2 cable(s) 2.5-2.5 mm²flexible without cable end, control circuit: screw clamp terminals 1 cable(s) 2.5-2.5 mm²flexible with cable end, control circuit: screw clamp terminals 2 cable(s) 1.5-1.5 mm²flexible with cable end, control circuit: screw clamp terminals 1 cable(s) 1.5-1.5 mm²solid without cable end, control circuit: screw clamp terminals 2 cable(s) 1.5-1.5 mm²solid without cable end, power circuit: screw clamp terminals 1 cable(s) 6-6 mm²flexible without cable end, power circuit: screw clamp terminals 2 cable(s) 4-4 mm²flexible without cable end, power circuit: screw clamp terminals 1 cable(s) 6-6 mm²flexible with cable end
contactor application motor control, heating, lighting
control circuit type AC at 50 Hz
control circuit voltage limits drop-out: 0.2...0.75 Uc at 50 Hz (at <50 °C), operational: 0.85...1.1 Uc at 50 Hz (at <50 °C)
control type remote control
depth 62.5 mm
device short name GC25
heat dissipation 1.3-1.3 W at 50/60 Hz
height 81 mm
hold-in power consumption in VA 3.8-3.8 VA 50 Hz (at 20 °C)
inrush power in VA 15-15 VA 50 Hz (at 20 °C)
IP degree of protection IP40 conforming to VDE 0106 (in enclosure), IP20 conforming to VDE 0106
Irms rated making capacity 68 A at 400 V AC for power circuit conforming to IEC 61095
maximum operating rate 300 cyc/h 50 °C
mechanical durability 1000000 cycles
mounting mode clip-on
mounting support DIN rail
net weight 0.11 kg
operating altitude <= 3000 m
operating position 30°/vertical
operating time 10...25 ms opening, 10...30 ms closing
pole contact composition 1 NO
Poles Description 1P
power dissipation per pole 1.6 W
product or component type modular contactor
protective treatment TC
Quantity per set set of 12
range TeSys
rated breaking capacity 68 A at 400 V for power circuit conforming to IEC 61095
rated operational voltage limits <= 250 V AC
tightening torque control circuit: 0.8 N.m - on screw clamp terminals, power circuit: 0.8 N.m - on screw clamp terminals
total number of 18 mm modules 1
utilisation category AC-7B, AC-7A
width 17.5 mm
[Icw] rated short-time withstand current 200 A 40 °C - 10 s for power circuit, 62 A 40 °C - 30 s for power circuit
ambient air temperature for operation -5-50 °C
standards IEC 61095, IEC 60947-5
[Ie] rated operational current 25 A AC-7A, 8.5 A AC-7B
mechanical robustness shocks contactor open: 10 Gn for 11 ms, shocks contactor closed: 15 Gn for 11 ms, vibrations contactor open: 2 Gn, 5...300 Hz, vibrations contactor closed: 3 Gn, 5...300 Hz
Electrical Durability AC-7A: 100000 cycles, AC-7B: 100000 cycles

Seller Information

Documents

Reviews

Write Your Own Review
You're reviewing: TeSys GC - modular contactor - 25 A - 1 NO - coil 220...240 V AC
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.