TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 - <= 440 V 40 A - 48 V AC coil

LC1D258E7
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Product Details

Activity PPCTR
Pincode Group default
Part Number LC1D258E7
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit, 40 A (at 60 °C) for power circuit
[Uc] control circuit voltage 48 V AC 50/60 Hz
[Ui] rated insulation voltage power circuit: 690 V conforming to IEC 60947-4-1, power circuit: 600 V CSA certified, power circuit: 600 V UL certified, signalling circuit: 690 V conforming to IEC 60947-1, signalling circuit: 600 V CSA certified, signalling circuit: 600 V UL certified
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 40 A gG at <= 690 V coordination type 2 for power circuit
auxiliary contact composition 1 NO + 1 NC
auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
average impedance 2 mOhm - Ith 40 A 50 Hz for power circuit
climatic withstand conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat
coil technology without built-in suppressor module
compatibility code LC1D
connections - terminals control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 2.5-16 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: solid without cable end
contact compatibility M6
contactor application resistive load
control circuit type AC at 50/60 Hz
control circuit voltage limits 0.3...0.6 Uc (-40-60 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz
depth 99 mm
device short name LC1D
fire resistance 850 °C conforming to IEC 60695-2-1
flame retardance V1 conforming to UL 94
heat dissipation 2-3 W at 50/60 Hz
height 91 mm
hold-in power consumption in VA 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C), 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
inrush power in VA 70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
IP degree of protection IP20 front face conforming to IEC 60529
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947
maximum operating rate 3600 cyc/h 60 °C
mechanical durability 15 Mcycles
minimum switching current 5 mA for signalling circuit
minimum switching voltage 17 V for signalling circuit
mounting support rail, plate
net weight 0.425 kg
non-overlap time 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
operating altitude 0...3000 m
operating time 12...22 ms closing, 4...19 ms opening
overvoltage category III
permissible ambient air temperature around the device -40-60 °C, 60-70 °C with derating
pole contact composition 2 NO + 2 NC
Poles Description 4P
pollution degree 3
power dissipation per pole 3.2 W AC-1
product certifications UL, CSA, CCC, EAC, UKCA, CB, EU-RO-MR by DNV-GL
product or component type contactor
protective cover with
protective treatment TH conforming to IEC 60068-2-30
range of product TeSys Deca
rated breaking capacity 450 A at 440 V for power circuit conforming to IEC 60947
rated operational voltage limits power circuit: <= 690 V AC 25...400 Hz
safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
signalling circuit frequency 25...400 Hz
tightening torque control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2, control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2, power circuit: 1.8 N.m - on screw clamps terminals - with screwdriver flat Ø 6 mm, power circuit: 1.8 N.m - on screw clamps terminals - with screwdriver Philips No 2, power circuit: 1.8 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
utilisation category AC-1, AC-3, AC-3e, AC-4
width 45 mm
[Icw] rated short-time withstand current 240 A 40 °C - 10 s for power circuit, 380 A 40 °C - 1 s for power circuit, 50 A 40 °C - 10 min for power circuit, 120 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
standards EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, GB/T 14048.4
[Ie] rated operational current 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
insulation resistance > 10 MOhm for signalling circuit
mechanical robustness vibrations contactor open (2 Gn, 5...300 Hz) , vibrations contactor closed (4 Gn, 5...300 Hz) , shocks contactor closed (15 Gn for 11 ms) , shocks contactor open (8 Gn for 11 ms)
Electrical Durability 1.4 Mcycles 40 A AC-1 at Ue <= 440 V

Seller Information

Documents

Reviews

Write Your Own Review
You're reviewing: TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 - <= 440 V 40 A - 48 V AC coil
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.

Frequently Bought Together

LADN22 Auxiliary contact block, TeSys D, 2NO + 2NC, front mounting, screw terminals.
LADN22

In stock

AED 59.00
AED 88.48
Auxiliary contact block, TeSys D, 1NO + 1NC, front mounting, screw terminals
LADN11

In stock

AED 29.00
AED 44.08
Auxiliary contact block, TeSys D, 2NO, front mounting, screw clamp terminals
LADN20

In stock

AED 30.00
AED 44.70
Time delay auxiliary contact block, TeSys D, 1NO + 1NC, on delay 0.1-30s, front, screw clamp terminals
LADT2

In stock

AED 148.00
AED 224.35
Auxiliary contact block, TeSys D, 3NO + 1NC, front mounting, screw clamp terminals
LADN31

In stock

AED 57.00
AED 86.61
Auxiliary contact block, TeSys D, 4NO, front mounting, screw clamp terminals
LADN40

In stock

AED 57.00
AED 86.61
Time delay auxiliary contact block, TeSys D, 1NO + 1NC, off delay 1-30s, front, screw clamp terminals
LADR2

In stock

AED 148.00
AED 224.35
Time delay auxiliary contact block, TeSys D, 1NO + 1NC, on delay 10-180s, front, screw clamp terminals
LADT4

In stock

AED 157.00
AED 237.12