Part Number |
LC1D80P7 |
Weight |
1.566 kg |
Package1 Length*Width*Height |
14.0 cm x 13.5 cm x 9.5 cm |
Country of Manufacturing |
Czech Republic |
[Ie] rated operational current |
125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
[Ith] conventional free air thermal current |
10 A (at 60 °C) for signalling circuit, 125 A (at 60 °C) for power circuit |
[Uc] control circuit voltage |
230 V AC 50/60 Hz |
[ue] Rated Operational Voltage |
power circuit: <= 300 V DC 25...400 Hz, power circuit: <= 690 V AC |
[Ui] rated insulation voltage |
power circuit: 600 V CSA certified, power circuit: 600 V UL certified, power circuit: 1000 V conforming to IEC 60947-4-1, signalling circuit: 690 V conforming to IEC 60947-1, signalling circuit: 600 V CSA certified, signalling circuit: 600 V UL certified |
[Uimp] rated impulse withstand voltage |
8 kV conforming to IEC 60947 |
ambient air temperature for operation |
-40-60 °C, 60-70 °C with derating |
ambient air temperature for storage |
-60-80 °C |
associated fuse rating |
10 A gG for signalling circuit conforming to IEC 60947-5-1, 200 A gG at <= 690 V coordination type 1 for power circuit, 160 A gG at <= 690 V coordination type 2 for power circuit |
auxiliary contact composition |
1 NO + 1 NC |
auxiliary contacts type |
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1 |
average impedance |
0.8 mOhm - Ith 125 A 50 Hz for power circuit |
climatic withstand |
conforming to IACS E10 exposure to damp heat |
coil technology |
without built-in suppressor module |
compatibility code |
LC1D |
connections - terminals |
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 4-50 mm² - cable stiffness: solid without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: solid without cable end |
contact compatibility |
M11 |
contactor application |
resistive load, motor control |
contactor coil voltage |
230 V AC standard |
control circuit type |
AC at 50/60 Hz standard |
control circuit voltage limits |
0.85...1.1 Uc (-40-55 °C):operational AC 60 Hz, 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-55 °C):operational AC 50 Hz, 1...1.1 Uc (55-70 °C):operational AC 50/60 Hz |
depth |
130 mm |
device short name |
LC1D |
electrical durability |
0.8 Mcycles 125 A AC-1 at Ue <= 440 V, 1.5 Mcycles 80 A AC-3 at Ue <= 440 V, 1.5 Mcycles 80 A AC-3e at Ue <= 440 V |
fire resistance |
850 °C conforming to IEC 60695-2-1 |
flame retardance |
V1 conforming to UL 94 |
heat dissipation |
6-10 W at 50/60 Hz |
height |
127 mm |
hold-in power consumption in VA |
26-26 VA 60 Hz cos phi 0.3 (at 20 °C), 26-26 VA 50 Hz cos phi 0.3 (at 20 °C) |
inrush power in VA |
245-245 VA 60 Hz cos phi 0.75 (at 20 °C), 245-245 VA 50 Hz cos phi 0.75 (at 20 °C) |
insulation resistance |
> 10 MOhm for signalling circuit |
IP degree of protection |
IP20 front face conforming to IEC 60529 |
Irms rated making capacity |
140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1100 A at 440 V for power circuit conforming to IEC 60947 |
maximum operating rate |
3600 cyc/h 60 °C |
mechanical durability |
4 Mcycles |
mechanical robustness |
vibrations contactor open: 2 Gn, 5...300 Hz, shocks contactor open: 8 Gn for 11 ms, vibrations contactor closed: 3 Gn, 5...300 Hz, shocks contactor closed: 10 Gn for 11 ms |
minimum switching current |
5 mA for signalling circuit |
minimum switching voltage |
17 V for signalling circuit |
motor power hp |
7.5 hp at 120 V AC 50/60 Hz for 1 phase motors, 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 30 hp at 230/240 V AC 50/60 Hz for 3 phases motors, 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
motor power kW |
22 kW at 220...230 V AC 50 Hz (AC-3), 37 kW at 380...400 V AC 50 Hz (AC-3), 45 kW at 415...440 V AC 50 Hz (AC-3), 55 kW at 500 V AC 50 Hz (AC-3), 45 kW at 660...690 V AC 50 Hz (AC-3), 15 kW at 400 V AC 50 Hz (AC-4), 22 kW at 220...230 V AC 50/60 Hz (AC-3e), 37 kW at 380...400 V AC 50/60 Hz (AC-3e), 45 kW at 415...440 V AC 50/60 Hz (AC-3e), 55 kW at 500 V AC 50/60 Hz (AC-3e), 45 kW at 660...690 V AC 50/60 Hz (AC-3e) |
motor starter type |
direct on-line contactor |
mounting support |
rail, plate |
net weight |
1.59 kg |
non-overlap time |
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
operating altitude |
0...3000 m |
operating time |
20...35 ms closing, 6...20 ms opening |
overvoltage category |
III |
permissible ambient air temperature around the device |
-40-60 °C, 60-70 °C with derating |
pole contact composition |
3 NO |
Poles Description |
3P |
pollution degree |
3 |
power dissipation per pole |
5.1 W AC-3, 12.5 W AC-1, 5.1 W AC-3e |
power range |
55-100 kW at 480-500 V 3 phases, 15-25 kW at 200-240 V 3 phases, 30-50 kW at 380-440 V 3 phases, 30-50 kW at 480-500 V 3 phases |
product certifications |
DNV, LROS (Lloyds register of shipping), GOST, CCC, GL, RINA, BV, CSA, UL |
product or component type |
contactor |
protective cover |
with |
protective treatment |
TH conforming to IEC 60068-2-30 |
range |
TeSys |
range of product |
TeSys Deca |
rated breaking capacity |
1100 A at 440 V for power circuit conforming to IEC 60947 |
rated operational voltage limits |
power circuit: <= 300 V DC 25...400 Hz, power circuit: <= 690 V AC |
safety reliability level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
signalling circuit frequency |
25...400 Hz |
standards |
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 |
tightening torque |
control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2, power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm, power circuit: 12 N.m - on connector hexagonal screw head 4 mm, control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
utilisation category |
AC-3, AC-3e, AC-4, AC-1 |
width |
85 mm |
[Icw] rated short-time withstand current |
640 A 40 °C - 10 s for power circuit, 990 A 40 °C - 1 s for power circuit, 135 A 40 °C - 10 min for power circuit, 320 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
standards |
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 |
[Ie] rated operational current |
125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
insulation resistance |
> 10 MOhm for signalling circuit |
mechanical robustness |
vibrations contactor open (2 Gn, 5...300 Hz) , shocks contactor open (8 Gn for 11 ms) , vibrations contactor closed (3 Gn, 5...300 Hz) , shocks contactor closed (10 Gn for 11 ms) |
Electrical Durability |
0.8 Mcycles 125 A AC-1 at Ue <= 440 V, 1.5 Mcycles 80 A AC-3 at Ue <= 440 V, 1.5 Mcycles 80 A AC-3e at Ue <= 440 V |