Part Number ATS01N109FT
[Uc] control circuit voltage 110 V AC +/- 10 % at 35 mA, 24 V AC/DC +/- 10 % at 30 mA, 240 V AC +/- 10 % at 80 mA
[Us] rated supply voltage 110...480 V - 10...10 %
ambient air temperature for storage -25-70 °C conforming to EN/IEC 60947-4-2
compatibility code ATS01N1
current consumption 45 A at nominal load
depth 131 mm
device short name ATS01
operating altitude <= 1000 m without derating, > 1000 m with current derating of 2.2 % per additional 100 m
operating position vertical +/- 10 degree
output voltage <= power supply voltage
pollution degree 2 conforming to EN/IEC 60947-4-2
power dissipation in W 1 W at full load and at end of starting, 46 W in transient state
power range 1.1-2 kW at 200-240 V 1 phase, 2.2-3 kW at 200-240 V 3 phases, 4-6 kW at 380-440 V 3 phases
product certifications C-Tick, B44.1-96/ASME A17.5 for starter wired to the motor delta terminal, GOST, CSA, CCC, UL
product or component type soft starter
range of product Altistart 01
relative humidity 5-95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27
supply voltage limits 99-528 V
tightening torque 0.5-0.5 N.m, 1.9-2.5 N.m
utilisation category AC-53B conforming to EN/IEC 60947-4-2
width 45 mm
IcL starter rating 9:00 AM
Discrete output current 2 A DC-13, 3 A AC-15
Type of start start with voltage ramp
Starting time 1 s / 100 , 5 s / 20 , adjustable from 1 to 5 s
Assembly style with heat sink
Starting torque 30...80 % of starting torque of motor connected directly on the line supply
Supply frequency 50...60 Hz - 5...5 %
vibration resistance 1 gn (f= 13-150 Hz) conforming to EN/IEC 60068-2-6, 1.5 mm peak to peak (f= 3-13 Hz) conforming to EN/IEC 60068-2-6
ambient air temperature for operation -10-40 °C (without derating), 40-50 °C (with current derating of 2 % per °C)
standards EN/IEC 60947-4-2

Seller Information

Documents

Reviews

Write Your Own Review
You're reviewing: soft starter for asynchronous motor - ATS01 - 9 A - 110..480V - 1.1..4 KW
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.

Frequently Bought Together

Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals
GV2ME14

In stock

AED 162.00
AED 244.28
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 230...240 V AC coil
LC1K0910U7

In stock

AED 58.00
AED 87.79
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 220...230 V AC coil
LC1K0910M7

In stock

AED 58.00
AED 87.79
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 110 V AC coil
LC1K0910F7

In stock

AED 58.00
AED 87.79
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V AC coil
LC1K0910B7

In stock

AED 58.00
AED 87.79
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NC aux. - 230...240 V AC coil
LC1K0901U7

In stock

AED 58.00
AED 87.79
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NC aux. - 24 V AC coil
LC1K0901B7

In stock

AED 58.00
AED 87.93
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NC aux. - 110 V AC coil
LC1K0901F7

In stock

AED 58.00
AED 87.93