motor voltage and temperature control relay - RM35-T - 24..240 V AC/DC - 2 NO
Excl. Tax
Excl. Tax
All Sellers
Seller | Price | Delivery | Shipping Cost | ||
---|---|---|---|---|---|
View Seller Profile
B2B Network
|
|
Shipping Cost
|
No sellers found for this product.
motor voltage and temperature control relay - RM35-T - 24..240 V AC/DC - 2 NO
Excl. Tax
Excl. Tax
Description
Product Details
Activity | IDSIG |
---|---|
Pincode Group | default |
Part Number | RM35TM250MW |
Rated current | 5:00 AM |
[Uc] control circuit voltage | <= 3.6 V of temperature control circuit (T1-T2 terminals open) |
[Ui] rated insulation voltage | 400 V conforming to IEC 60664-1 |
ambient air temperature for storage | -40-70 °C |
compatibility code | RM3 |
connections - terminals | screw connectors |
IP degree of protection | IP20 (terminals) conforming to IEC 60529, IP30 (casing) conforming to IEC 60529 |
marking | CE |
maximum switching voltage | 250 V AC, 250 V DC |
mechanical durability | 30000000 cycles |
minimum switching current | 10 mA at 5 V DC |
mounting support | 35 mm symmetrical DIN rail conforming to EN/IEC 60715 |
net weight | 0.13 kg |
operating position | any position without derating |
operating rate | <= 360 operations/hour full load |
overvoltage category | III conforming to IEC 60664-1 |
pollution degree | 3 conforming to IEC 60664-1 |
product certifications | CSA, C-Tick, GOST, UL, GL |
product or component type | 3-phase control relay |
range of product | Harmony Control Relays |
relative humidity | 95-95 % at 55-55 °C conforming to IEC 60068-2-30 |
shock resistance | 15 gn for 11 ms conforming to IEC 60255-21-1 |
supply voltage limits | 20.4-264 V AC, 20.4-264 V DC |
tightening torque | 0.6-1 N.m conforming to IEC 60947-1 |
tripping threshold | 3100 Ohm +/- 10 % for temperature control circuit |
utilisation category | AC-12 conforming to IEC 60947-5-1, AC-13 conforming to IEC 60947-5-1, AC-14 conforming to IEC 60947-5-1, AC-15 conforming to IEC 60947-5-1, DC-12 conforming to IEC 60947-5-1, DC-13 conforming to IEC 60947-5-1 |
width | 35 mm |
contacts type and composition | 2 NO |
Supply frequency | 50/60 Hz +/- 10 % |
Maximum power consumption in W | 0.5 W DC |
Reset time | 10000 ms output |
Immunity to microbreaks | 20 ms at 20.4 V |
Power consumption in VA | 0-4 VA at 24...240 V AC |
Voltage range | 176...528 V |
Switching capacity in VA | 1250 VA |
Nominal output current | 5:00 AM |
Housing material | self-extinguishing plastic |
Time delay type | fixed 0.3 s |
Maximum switching current | 5 A AC, 5 A DC |
Output contacts | 2 NO |
Dielectric test voltage | 2 kV, 1 min AC 50 Hz |
Relay monitored parameters | phase failure detection, phase sequence, test/reset button, motor temperature via PTC probe, selection (with or without memory) |
Measurement range | 208...480 V voltage AC, 0...20 Ohm short-circuit detection |
Relay name | RM35TM |
Relay type | motor temperature control relay |
Resistance across terminals | 602 mOhm |
Run-up delay at power-up | 500 ms |
Non-dissipating shock wave | 4 kV |
Control circuit frequency | 50...60 Hz +/- 10 % |
Measurement voltage limits | 176-528 V AC |
Short-circuit current | 0.007 A temperature sensing circuit (T1-T2 terminals short circuited) |
Reset threshold | 1650 Ohm +/- 10 % for temperature control circuit |
Maximum resistance | 1500 Ohm for temperature sensor at 20 °C |
vibration resistance | 0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6, 1 gn (f= 57.6-150 Hz) conforming to IEC 60255-21-1 |
electromagnetic compatibility | emission standard for industrial environments conforming to EN/IEC 61000-6-4, emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3, immunity for industrial environments conforming to EN/IEC 61000-6-2 |
ambient air temperature for operation | -20-50 °C |
standards | EN/IEC 60255-6, IEC 60034-11-2 |
local signalling | LED (green) for power ON, LED (yellow) for phase of relay (R2), LED (yellow) for temperature of relay (R1) |
insulation resistance | > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5, > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1, > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5, > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1, > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5, > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1 |
Directives | 73/23/EEC - low voltage directive, 89/336/EEC - electromagnetic compatibility |
Electrical Durability | 10000 cycles |