Activity |
PPCTR |
Pincode Group |
UAE |
Show Accessory |
No |
Part Number |
GV2P07 |
Weight |
330.0 g |
Package1 Length*Width*Height |
10.0 cm x 9.0 cm x 5.0 cm |
Rated current |
2.5 A |
[Ith] conventional free air thermal current |
2.5 A conforming to IEC 60947-4-1 |
[ue] Rated Operational Voltage |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ui] rated insulation voltage |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947-2 |
ambient air temperature for operation |
-20-60 °C |
ambient air temperature for storage |
-40-80 °C |
breaking capacity |
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 8 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
climatic withstand |
conforming to IACS E10 |
colour |
dark grey |
compatibility code |
GV2P |
control type |
rotary handle |
depth |
97 mm |
device application |
motor protection |
device short name |
GV2P |
direct connector |
without |
electrical durability |
100000 cycles for AC-3 at 415 V, at 415 V |
fire resistance |
960 °C conforming to IEC 60695-2-11 |
fixing mode |
35 mm symmetrical DIN rail: clipped, panel: screwed (with 2 x M4 screws) |
height |
89 mm |
IK degree of protection |
IK04 |
IP degree of protection |
IP20 conforming to IEC 60529 |
magnetic tripping current |
33.5-33.5 A |
maximum operating rate |
25 cyc/h |
mechanical durability |
100000 cycles |
mechanical robustness |
shocks: 30 Gn conforming to IEC 60068-2-27, vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6 |
motor power kW |
0.75-0.75 kW at 400/415 V AC 50/60 Hz, 1.1-1.1 kW at 500 V AC 50/60 Hz, 1.5-1.5 kW at 690 V AC 50/60 Hz |
network frequency |
50/60 Hz conforming to IEC 60947-4-1 |
network type |
AC |
operating altitude |
2000 m |
operating position |
any position |
phase failure sensitivity |
yes conforming to IEC 60947-4-1 |
Poles Description |
3P |
power dissipation per pole |
2.5 W |
product certifications |
CCC, UL, CSA, EAC, ATEX, LROS (Lloyds register of shipping), BV, RINA, DNV-GL, UKCA |
product or component type |
motor circuit breaker |
range |
TeSys Deca |
range of product |
TeSys GV2 |
rated duty |
continuous conforming to IEC 60947-4-1 |
rated operational voltage limits |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
standards |
EN/IEC 60947-2, EN/IEC 60947-4-1 |
suitability for isolation |
yes conforming to IEC 60947-1 § 7-1-6 |
thermal protection adjustment range |
1-1.6 A conforming to IEC 60947-4-1 |
tightening torque |
1.7 N.m - on screw clamp terminal |
trip unit rating |
1.6-2.5 A |
trip unit technology |
thermal-magnetic |
utilisation category |
category A conforming to IEC 60947-2, AC-3 conforming to IEC 60947-4-1 |
width |
45 mm |
[Ics] rated service short-circuit breaking capacity |
100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
ambient air temperature for operation |
-20-60 °C |
standards |
EN/IEC 60947-2, EN/IEC 60947-4-1 |
mechanical robustness |
shocks: 30 Gn for 11 ms, vibrations: 5 Gn, 5...150 Hz |
Electrical Durability |
100000 cycles for AC-3 at 415 V In |