Part Number LC1K09004P7
[Ith] conventional free air thermal current 20 A (at 50 °C) for power circuit
[Uc] control circuit voltage 230 V AC 50/60 Hz
[Ui] rated insulation voltage power circuit: 600 V conforming to UL 508, power circuit: 690 V conforming to IEC 60947-4-1, power circuit: 600 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage 8 kV
ambient air temperature for storage -50-80 °C
associated fuse rating 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit
average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
compatibility code LC1K
connections - terminals screw clamp terminals 1 cable(s) 1.5-4 mm²solid, screw clamp terminals 1 cable(s) 0.75-4 mm²flexible without cable end, screw clamp terminals 1 cable(s) 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 cable(s) 1.5-4 mm²solid, screw clamp terminals 2 cable(s) 0.75-4 mm²flexible without cable end, screw clamp terminals 2 cable(s) 0.34-1.5 mm²flexible with cable end
contactor application resistive load
control circuit type AC at 50/60 Hz
control circuit voltage limits operational: 0.8...1.15 Uc (at <50 °C), drop-out: 0.2...0.75 Uc (at <50 °C)
depth 57 mm
device application control
device short name LC1K
flame retardance V1 conforming to UL 94, requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
heat dissipation 1.3-1.3 W
height 58 mm
hold-in power consumption in VA 4.5-4.5 VA (at 20 °C)
inrush power in VA 30-30 VA (at 20 °C)
IP degree of protection IP2X conforming to VDE 0106
Irms rated making capacity 110 A AC for power circuit conforming to NF C 63-110, 110 A AC for power circuit conforming to IEC 60947
maximum operating rate 3600 cyc/h
mechanical durability 10 Mcycles
mounting support plate, rail
net weight 0.18 kg
operating altitude 2000 m without derating
operating time 10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing
overvoltage category III
pole contact composition 4 NO
Poles Description 4P
product certifications CB Scheme, CCC, UL, CSA, EAC, CE, UKCA
product or component type contactor
protective treatment TC conforming to IEC 60068, TC conforming to DIN 50016
range TeSys
range of product TeSys K
rated breaking capacity 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947
rated operational voltage limits power circuit: 690 V AC 50/60 Hz
safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
signalling circuit frequency <= 400 Hz
tightening torque 0.8-1.3 N.m - on screw clamp terminals Philips No 2, 0.8-1.3 N.m - on screw clamp terminals flat Ø 6 mm, 0.8-1.3 N.m - on screw clamp terminals pozidriv No 2
utilisation category AC-1
width 45 mm
[Icw] rated short-time withstand current 90 A 50 °C - 1 s for power circuit, 85 A 50 °C - 5 s for power circuit, 80 A 50 °C - 10 s for power circuit, 60 A 50 °C - 30 s for power circuit, 45 A 50 °C - 1 min for power circuit, 40 A 50 °C - 3 min for power circuit, 20 A 50 °C - >= 15 min for power circuit
standards EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1
[Ie] rated operational current 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit, 16 A (at <70 °C) at 690 V AC AC-1 for power circuit
mechanical robustness shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6, vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Electrical Durability 0.18 Mcycles 20 A AC-1 at Ue <= 440 V

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review
You're reviewing: contactor, TeSys K, 4P(4NO), AC-1, 440V 20A, 230V AC coil
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.

Frequently Bought Together

Auxiliary contact block, TeSys K, 2NO + 2NC, screw terminals
LA1KN22

In stock

AED 40.00
AED 59.93
Auxiliary contact block, TeSys K, 1NO + 1NC, screw terminals
LA1KN11

In stock

AED 21.00
AED 34.00
Auxiliary contact block, TeSys K, 3NO + 1NC, front mounting, screw clamp terminals
LA1KN31

In stock

AED 37.05
AED 60.00
Auxiliary contact block, TeSys K, 4NO, front mounting, screw clamp terminals
LA1KN40

In stock

AED 40.00
AED 60.00
Auxiliary contact block, TeSys K, 1NO + 3NC, front mounting, screw clamp terminals
LA1KN13

In stock

AED 40.00
AED 59.86
Auxiliary contact block, TeSys K, 4NC, front mounting, screw clamp terminals
LA1KN04

In stock

AED 40.00
AED 60.00
Auxiliary contact block, TeSys K, 2NC,front mounting, screw clamp terminals
LA1KN02

In stock

AED 22.00
AED 33.91
Auxiliary contact block, TeSys K, 2NO, front mounting, screw clamp terminals
LA1KN20

In stock

AED 22.00
AED 33.91