Activity |
PPCCB |
Part Number |
EZC100H2100 |
[ics] Rated Service Breaking Capacity |
15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2, 5 kA at 125 V DC conforming to IEC 60947-2, 5 kA at 250 V DC conforming to IEC 60947-2, 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2, 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2, 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
[ui] Rated Insulation Voltage |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947-2 |
Breaking Capacity |
10 kA Icu at 125 V DC 1P conforming to IEC 60947-2, 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2, 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2, 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2, 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 |
breaking capacity |
10 kA Icu at 125 V DC 1P conforming to IEC 60947-2, 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2, 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2, 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2, 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 |
Breaking Capacity Code |
H |
Circuit Breaker Name |
Easypact EZC100H |
Connection Pitch |
25 mm |
Downside Connection |
front |
Earth-leakage Protection |
without |
Neutral Protection Setting |
without protection |
Protected Poles Description |
2t |
suitability for isolation |
yes conforming to IEC 60947-2 |
Trip Unit Name |
TM-D |
trip unit rating |
100-100 A at 50 °C |
trip unit technology |
thermal-magnetic |
Upside Connection |
front |
utilisation category |
category A |
Weight |
571.0 g |
Package1 Length*Width*Height |
6.0 cm x 14.0 cm x 9.5 cm |
Country of Manufacturing |
Thailand |
[in] Rated Current |
100 A at 40 °C |
[ue] Rated Operational Voltage |
550 V AC 50/60 Hz conforming to IEC 60947-2, 250 V DC conforming to IEC 60947-2 |
ambient air temperature for operation |
-25-70 °C |
ambient air temperature for storage |
-35-85 °C |
compatibility code |
EZC100 |
control type |
toggle |
depth |
60 mm |
device application |
distribution |
device short name |
Easypact EZC100H |
Electrical Durability |
category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 |
height |
130 mm |
IK degree of protection |
IK07 conforming to IEC 62262 |
IP degree of protection |
IP20 conforming to IEC 60529 |
local signalling |
positive contact indication |
Market Segment |
small commercial |
mechanical durability |
8500 cycles |
mounting mode |
fixed |
mounting support |
backplate |
network frequency |
50/60 Hz |
network type |
AC, DC |
Poles Description |
2P |
pollution degree |
3 conforming to IEC 60664-1, 3 conforming to IEC 947-1 |
Product Name |
EasyPact EZC |
product or component type |
circuit breaker |
Protection Type |
overload protection, short-circuit protection |
range |
EasyPact |
range of product |
EasyPact |
standards |
EN/IEC 60947-1, GB/T 14048.2, JIS C8201-2-2, EN/IEC 60947-2 |
width |
50 mm |
ambient air temperature for operation |
-25-70 °C |
standards |
EN/IEC 60947-1, GB/T 14048.2, JIS C8201-2-2, EN/IEC 60947-2 |
local signalling |
positive contact indication |
[Ui] rated insulation voltage |
690 V AC 50/60 Hz conforming to IEC 60947-2 |