analog input module X80 - 8 inputs - temperature

BMXART0814
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Product Details

Activity IDPAC
Pincode Group default
Part Number BMXART0814
ambient air temperature for storage -40-85 °C
current consumption 150 mA at 3.3 V DC
Detection Type open circuit Cu 10, open circuit Ni 100, open circuit Ni 1000, open circuit Pt 100, open circuit Pt 1000, open circuit thermocouple B, open circuit thermocouple E, open circuit thermocouple J, open circuit thermocouple K, open circuit thermocouple L, open circuit thermocouple N, open circuit thermocouple R, open circuit thermocouple S, open circuit thermocouple T, open circuit thermocouple U
Measurement Resolution 0.1 °C Cu 10, 0.1 °C Ni 100, 0.1 °C Ni 1000, 0.1 °C Pt 100, 0.1 °C Pt 1000, 0.1 °C thermocouple B, 0.1 °C thermocouple E, 0.1 °C thermocouple J, 0.1 °C thermocouple K, 0.1 °C thermocouple L, 0.1 °C thermocouple N, 0.1 °C thermocouple R, 0.1 °C thermocouple S, 0.1 °C thermocouple T, 0.1 °C thermocouple U, 1280/2exp14 mV +/- 1.28 V, 160/2exp14 mV +/- 160 mV, 320/2exp14 mV +/- 320 mV, 40/2exp14 mV +/- 40 mV, 12.5 mOhm 400 Ohm, 125 mOhm 4000 Ohm, 640/2exp14 mV +/- 640 mV, 80/2exp14 mV +/- 80 mV
Maximum Wiring Resistance 20 Ohm 2 wires Cu 10, 20 Ohm 2 wires Ni 100, 20 Ohm 2 wires Pt 100, 20 Ohm 3 wires Cu 10, 20 Ohm 3 wires Ni 100, 20 Ohm 3 wires Pt 100, 200 Ohm 2 wires Ni 1000, 200 Ohm 2 wires Pt 1000, 200 Ohm 3 wires Ni 1000, 200 Ohm 3 wires Pt 1000, 50 Ohm 4 wires Cu 10, 50 Ohm 4 wires Ni 100, 50 Ohm 4 wires Pt 100, 500 Ohm 4 wires Ni 1000, 500 Ohm 4 wires Pt 1000
IP degree of protection IP20
net weight 0.165 kg
operating altitude 0...2000 m, 2000...5000 m with derating factor
product certifications CE, EAC, UL, CSA, Merchant Navy, RCM
product or component type analog input module
range of product Modicon X80
relative humidity 5-95 % at 55-55 °C without condensation
shock resistance 30 gn
MTBF reliability 900000 H
Measurement error +/- 0.7 °C Ni 1000 25 °C, +/- 2 °C Pt 100 0...60 °C, +/- 2 °C Pt 1000 0...60 °C, +/- 2.1 °C Ni 100 25 °C, +/- 2.1 °C Pt 100 25 °C, +/- 2.1 °C Pt 1000 25 °C, +/- 2.7 °C thermocouple U 25 °C, +/- 2.8 °C thermocouple J 25 °C, +/- 3 °C Ni 100 0...60 °C, +/- 3 °C thermocouple L 25 °C, +/- 3.2 °C thermocouple R 25 °C, +/- 3.2 °C thermocouple S 25 °C, +/- 3.5 °C thermocouple B 25 °C, +/- 3.7 °C thermocouple E 25 °C, +/- 3.7 °C thermocouple K 25 °C, +/- 3.7 °C thermocouple N 25 °C, +/- 3.7 °C thermocouple T 25 °C, +/- 4 °C Cu 10 0...60 °C, +/- 4 °C Cu 10 25 °C, +/- 4.5 °C thermocouple J 0...60 °C, +/- 4.5 °C thermocouple L 0...60 °C, +/- 4.5 °C thermocouple R 0...60 °C, +/- 4.5 °C thermocouple S 0...60 °C, +/- 4.5 °C thermocouple U 0...60 °C, +/- 5 °C thermocouple B 0...60 °C, +/- 5 °C thermocouple E 0...60 °C, +/- 5 °C thermocouple K 0...60 °C, +/- 5 °C thermocouple N 0...60 °C, +/- 5 °C thermocouple T 0...60 °C, <= 0.15 % of full scale +/- 1.28 V 0...60 °C, <= 0.15 % of full scale +/- 160 mV 0...60 °C, <= 0.15 % of full scale +/- 320 mV 0...60 °C, <= 0.15 % of full scale +/- 640 mV 0...60 °C, <= 0.15 % of full scale +/- 80 mV 0...60 °C, <= 0.2 % of full scale 4000 Ohm 0...60 °C, 0.05 % of full scale +/- 1.28 V 25 °C, 0.05 % of full scale +/- 160 mV 25 °C, 0.05 % of full scale +/- 320 mV 25 °C, 0.05 % of full scale +/- 40 mV 25 °C, 0.05 % of full scale +/- 640 mV 25 °C, 0.05 % of full scale +/- 80 mV 25 °C, 0.12 % of full scale 400 Ohm 25 °C, 0.12 % of full scale 4000 Ohm 25 °C, <= 0.2 % of full scale +/- 40 mV 0...60 °C, <= 0.3 % of full scale 400 Ohm 0...60 °C, 1.3 °C Ni 1000 0...60 °C
Maximum conversion value +/- 100 % 400 Ohm, +/- 100 % 4000 Ohm, +/- 102.5 % +/- 1.28 V, +/- 102.5 % +/- 160 mV, +/- 102.5 % +/- 320 mV, +/- 102.5 % +/- 40 mV, +/- 102.5 % +/- 640 mV, +/- 102.5 % +/- 80 mV
Type of filter first order digital filtering
Temperature drift 25 ppm/°C 400 Ohm, 25 ppm/°C 4000 Ohm, 25 ppm/°C Ni 1000, 25 ppm/°C thermocouple B, 25 ppm/°C thermocouple E, 25 ppm/°C thermocouple J, 25 ppm/°C thermocouple K, 25 ppm/°C thermocouple L, 25 ppm/°C thermocouple N, 25 ppm/°C thermocouple R, 25 ppm/°C thermocouple S, 25 ppm/°C thermocouple T, 25 ppm/°C thermocouple U, 30 ppm/°C +/- 1.28 V, 30 ppm/°C +/- 160 mV, 30 ppm/°C +/- 320 mV, 30 ppm/°C +/- 40 mV, 30 ppm/°C +/- 640 mV, 30 ppm/°C +/- 80 mV, 30 ppm/°C Cu 10, 30 ppm/°C Ni 100, 30 ppm/°C Pt 100, 30 ppm/°C Pt 1000
Recalibration internal
Cold junction compensation external by Pt100 probe
Analogue input resolution 15 bits + sign
Input level low level
Input output isolation isolated
Analogue input number 8
Differential mode rejection 60 dB 50/60 Hz
Nominal read cycle time 400 ms with temperature probe, 200 ms with thermocouple
Analog/digital conversion sigma delta 16 bits
Analogue input type voltage +/- 1.28 V, voltage +/- 160 mV, voltage +/- 320 mV, voltage +/- 40 mV, voltage +/- 640 mV, voltage +/- 80 mV, resistor 400 Ohm 2 wires, resistor 400 Ohm 3 wires, resistor 400 Ohm 4 wires, resistor 4000 Ohm 2 wires, resistor 4000 Ohm 3 wires, resistor 4000 Ohm 4 wires, temperature probe -100...+260 °C Cu 10, temperature probe -100...+450 °C Pt 100 conforming to UL/JIS, temperature probe -100...+450 °C Pt 1000 conforming to UL/JIS, temperature probe -200...+850 °C Pt 100 conforming to IEC, temperature probe -200...+850 °C Pt 1000 conforming to IEC, temperature probe -60...+180 °C Ni 100, temperature probe -60...+180 °C Ni 1000, thermocouple +130...+1820 °C thermocouple B, thermocouple +270...+1300 °C thermocouple N, thermocouple -200...+600 °C thermocouple U, thermocouple -200...+760 °C thermocouple J, thermocouple -200...+900 °C thermocouple L, thermocouple -270...+1000 °C thermocouple E, thermocouple -270...+1370 °C thermocouple K, thermocouple -270...+400 °C thermocouple T, thermocouple -50...+1769 °C thermocouple R, thermocouple -50...+1769 °C thermocouple S
Permitted overload on inputs +/- 7.5 V +/- 1.28 V, +/- 7.5 V +/- 160 mV, +/- 7.5 V +/- 320 mV, +/- 7.5 V +/- 40 mV, +/- 7.5 V +/- 640 mV, +/- 7.5 V +/- 80 mV
vibration resistance 3 gn
status LED 1 LED (green) RUN, 1 LED per channel (green) channel diagnostic, 1 LED (red) ERR, 1 LED (red) I/O
ambient air temperature for operation 0-60 °C
standards EN 61131-2, EN 61000-6-4, EN 61000-6-2, EN 61010-2-201
environmental characteristic 3C3 conforming to EN/IEC 60721-3-3, 3C4 conforming to EN/IEC 60721-3-3
Electrical Connection 40 ways 2 connectors
Directives 2014/35/EU - low voltage directive, 2014/30/EU - electromagnetic compatibility
Common Mode Rejection 120 dB 50/60 Hz

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review
You're reviewing: analog input module X80 - 8 inputs - temperature
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.

Frequently Bought Together

Processor module, Modicon M340 automation platform, max 1024 discrete + 256 analog I/O, Modbus, Ethernet
BMXP342020

In stock

AED 4,320.02
AED 4,848.07
Redundant processor module, Modicon M580, HSBY Level 2, Remote
BMEH582040

In stock

AED 16,771.90
shielded cord set - 40-way terminal - one end flying leads - for X80 I/O - 3 m
BMXFCW301S

In stock

AED 522.60
AED 539.49
shielded cord set - 40-way terminal - one end flying leads - for X80 I/O - 5 m
BMXFCW501S

In stock

AED 858.78
connection sub-base ABE7 - for distribution of 4 thermocouples
ABE7CPA412

In stock

AED 528.48
Redundant processor module, Modicon M580, HSBY Level 4, Remote
BMEH584040

In stock

AED 26,328.58
Redundant processor module, Modicon M580, HSBY Level 6, Remote
BMEH586040

In stock

AED 39,878.22
Processor module, Modicon M580, Level 1, Distributed
BMEP581020

In stock

AED 9,508.97