Acti9 Smartlink - Modbus RS485 slave - smart communication I/O module
- Description
- Specifications
- Environmental Data
- Documents
- Reviews
Description
Overview
| Activity | DPLVP |
|---|---|
| Range of product | ACTI9 |
| range of product | ECOSTRUXURE |
| Product or component type | SMART COMMUNICATION MODULE |
| Product name | ECOSTRUXURE I/O SMART LINK |
| Device short name | I/O Smart Link |
| Application type | LOAD CONTROLBREAKER STATUS MONITORINGBASIC ENERGY METERING E |
| Number max of connected devices | UP TO 11 WIRED DEVICES |
| Group of channels | 1 GROUP OF 11 DIGITAL CHANNELS |
| Maximum supply current | 1.5 A |
| [Us] rated supply voltage | 24 V DC +/- 20 % |
| Connectivity to devices | DIGITAL INPUT AND OUTPUTPULSE OUTPUT METER |
| Communication service | MODBUS SERVER FOR RS485 |
| Web server | BMS CONTROLLER COMPATIBLE |
| Application specific I/O | PULSE TOTALISING COUNTERPULSE CONVERTER |
| Protection type | AGAINST REVERSE POLARITY FOR AUXILIARY SUPPLYAGAINST REVERSE POLARITY FOR INPUTOVERVOLTAGE AT 33 V DC FOR DIGITAL OUTPUT |
| Immunity to microbreaks | 10 MS |
| Reset | FACTORY RESET ON FRONT FACEBY BOOTED PUSH-BUTTONBY ADDRESS ENCODERBY PLUG IN, PLUG OUT THE POWER SUPPLY |
| Input/output type | 2 INPUTS + 1 OUTPUT PER DIGITAL CHANNEL |
| Input type | CURRENT SINK FOR DIGITAL INPUT, 24 V DC +/- 20 % AT 2.5 MA |
| Maximum permanent current | 5 MA FOR DIGITAL INPUT |
| Electronic filtering time | 2 MS FOR DIGITAL INPUT FROM STATE 0 TO STATE 1 |
| Output type | LOGIC CURRENT SOURCE: 24 V - DC - 100 MA |
| Inrush current | 0.5 A FOR DIGITAL OUTPUT7 A FOR POWER SUPPLY |
| Local signalling | COMMUNICATION: 1 LED (YELLOW)STATUS: 1 LED (GREEN, ORANGE AND RED) |
| Type of setting | MODBUS ADDRESS 01...99 FOR ADDRESS ENCODERSRESET FOR ADDRESS ENCODERSRESET FOR PLUG IN, PLUG OUT THE AUXILIARY SUPPLY |
| Mounting position | HORIZONTAL AND VERTICAL ON DIN RAIL |
| Colour | WHITE (RAL 9003) |
| Location of connection | FRONT |
| Connections - terminals | SPRING-LOADED TERMINAL TI24 QTY: 11 FOR DIGITAL INPUT/OUTPUT, ORDERED SEPARATELYPLUG-IN CONNECTOR QTY: 1 FOR SUPPLY CIRCUITPLUG-IN CONNECTOR QTY: 1 FOR COMMUNICATION BUS |
| Clamping connection capacity | 2 X 0.2...2 X 1.5 MM² FOR TWISTED SHIELDED PAIRS CABLE, FLEXIBLE WITH CABLE END FOR COMMUNICATION BUS2 X 0.2...2 X 1.5 MM² FOR TWISTED SHIELDED PAIRS CABLE, FLEXIBLE WITHOUT CABLE END FOR COMMUNICATION BUS2 X 0.2...2 X 1.5 MM² FOR TWISTED SHIELDED PAIRS CABLE, RIGID WITH CABLE END FOR COMMUNICATION BUS2 X 0.2...2 X 1.5 MM² FOR TWISTED SHIELDED PAIRS CABLE, RIGID WITHOUT CABLE END FOR COMMUNICATION BUS1 X 0.2...1 X 1.5 MM², FLEXIBLE WITH CABLE END FOR CONTROL1 X 0.2...1 X 1.5 MM², FLEXIBLE WITHOUT CABLE END FOR CONTROL1 X 0.2...1 X 1.5 MM², RIGID WITH CABLE END FOR CONTROL1 X 0.2...1 X 1.5 MM², RIGID WITHOUT CABLE END FOR CONTROL2 X 0.2...2 X 1.5 MM², FLEXIBLE WITH CABLE END FOR SUPPLY CIRCUIT2 X 0.2...2 X 1.5 MM², FLEXIBLE WITHOUT CABLE END FOR SUPPLY CIRCUIT2 X 0.2...2 X 1.5 MM², RIGID WITH CABLE END FOR SUPPLY CIRCUIT2 X 0.2...2 X 1.5 MM², RIGID WITHOUT CABLE END FOR SUPPLY CIRCUIT |
| Wire stripping length | CONTROL: 10 MMSUPPLY CIRCUIT: 7 MMCOMMUNICATION BUS: 7 MM |
| Communication network type | RS485 MODBUS RTU CLIENT/SERVER SUB-D 9 4800 BPS, 9600 BPS, 19200 BPS, 38.4 KBPS |
| 9 mm pitches | 0 USEFUL |
| Height | 22.5 MM |
| Width | 359 MM |
| Depth | 42 MM |
| Product weight | 188 G |
| Provided equipment | SET OF 1 BUS CONNECTORSET OF 1 POWER SUPPLY CONNECTORSET OF 2 LOCKING CLIPS |
| Range compatibility | ACTI 9 ITL AUXILIARYLINERGY LINERGY FMACTI 9 IOF+SD 24ACTI 9 IACT24ACTI 9 IATL24POWERLOGIC PULSE OUTPUT METERACTI 9 RCA IC60ACTI 9 ACTI9 ICT AUXILIARYACTI 9 ACTI9 IC60ACTI 9 ACTI9 IIDACTI 9 ACTI9 ISW-NAACTI 9 ACTI9 IDPN VIGIACTI 9 ACTI9 C40MULTI9 MULTI9 C60ACTI 9 ACTI9 DT40ACTI 9 ACTI9 DT60ACTI 9 ACTI9 I-NAACTI 9 ACTI9 ITG40ACTI 9 ACTI9 IDPNACTI 9 ACTI9 REFLEX IC60 TI24 CONNECTOR |
| Commissioning interface | ECOSTRUXURE POWER COMMISSION |
| Market segment | BUILDINGSSMALL COMMERCIAL |
| Compatibility code | ACTI 9 SMARTLINK |
| IP degree of protection | IP20 |
| IK degree of protection | IK06 CONFORMING TO IEC 62262 |
| Pollution degree | 3 |
| Electromagnetic compatibility | RESISTANCE TO ELECTROSTATIC DISCHARGE (AIR DISCHARGE), CLASS B, 8 KV, CONFORMING TO IEC 61000-4-2RESISTANCE TO ELECTROSTATIC DISCHARGE (CONTACT DISCHARGE), CLASS B, 4 KV, CONFORMING TO IEC 61000-4-2RESISTANCE TO RADIATED ELECTROMAGNETIC FIELDS (80 MHZ...3 GHZ), CLASS A, 10 V/M, CONFORMING TO IEC 61000-4-3POWER SUPPLY: RESISTANCE TO RADIATED ELECTROMAGNETIC FIELDS (1.4…6 GHZ), CLASS A, 3 V/M, CONFORMING TO IEC 61000-4-3POWER SUPPLY: RESISTANCE TO FAST TRANSIENT (5...100 KHZ), CLASS B, 2 KV, CONFORMING TO IEC 61000-4-4INPUT/OUTPUT: RESISTANCE TO FAST TRANSIENT, CLASS B, 1 KV, CONFORMING TO IEC 61000-4-4COMMUNICATION BUS: RESISTANCE TO FAST TRANSIENT (0.15...80 MHZ), CLASS B, 1 KV, CONFORMING TO IEC 61000-4-4CONDUCTED EMC (0.15...80 MHZ), CLASS A, 3 V, CONFORMING TO IEC 61000-4-6CONDUCTED EMISSION (0.15...30 MHZ), CLASS B, CONFORMING TO IEC 61326-1CONDUCTED EMISSION (0.15...30 MHZ), CLASS B, CONFORMING TO CISPR 11RADIATED EMISSION (30...6000 MHZ), CLASS B, CONFORMING TO IEC 61326-1RADIATED EMISSION (30...6000 MHZ), CLASS B, CONFORMING TO CISPR 11POWER SUPPLY: SURGES (DM COUPLING 42 OHM), CLASS B, 1 KV, CONFORMING TO IEC 61000-4-5POWER SUPPLY: SURGES (CM COUPLING 42 OHM), CLASS B, 2 KV, CONFORMING TO IEC 61000-4-5COMMUNICATION BUS: SURGES (CM COUPLING 2 OHM), CLASS B, 1 KV, CONFORMING TO IEC 61000-4-5 |
| Environmental characteristic | CORROSIVE 3C2 CONFORMING TO IEC 60721-3-3SALT MIST 2 CONFORMING TO IEC 60068-2-52 |
| Vibration resistance | 1 GN, AMPLITUDE = 3.5 MM (F = 5…300 HZ)10 CYCLES CONFORMING TO EN/IEC 60068-2-6 |
| Shock resistance | 15 GN FOR 11 MS CONFORMING TO IEC 60068-2-27 |
| Fire resistance | OTHER PARTS: 650 °C ( 30 S ) CONFORMING TO IEC 60695-2-10ON CONNECTION TERMINALS: 960 °C ( 30 S ) CONFORMING TO IEC 60695-2-10 |
| Tropicalisation | 2 |
| Relative humidity | 0…93 % AT 40 °C |
| Operating altitude | 0...2000 M |
| Ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Standards | IEC 61010-2-201IEC 61010-1 |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.300 CM |
| Package 1 Width | 6.500 CM |
| Package 1 Length | 37.000 CM |
| Package 1 Weight | 242.000 G |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 32 |
| Package 2 Height | 30.000 CM |
| Package 2 Width | 30.000 CM |
| Package 2 Length | 40.000 CM |
| Package 2 Weight | 8.200 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| Mercury free | ✓ |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | End of Life Information (Download) |
| Total lifecycle Carbon footprint | 35 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 23.5061282635052 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 24 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.6059365135946421 |
| Carbon footprint of the distribution phase [A4] | 0.6 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.001838859801891558 |
| Carbon footprint of the installation phase [A5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 9.927592750156709 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 10 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.6144217354690374 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.6 kg CO2 eq. |
| SCIP Number | 2c4a7f95-9fbf-4b2e-bc7e-82ceeb851894 |
| REACh Regulation | Reference contains Substances of Very High Concern above the threshold (Download) |
| EU RoHS Directive | Compliant By Exemption (Download) |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Reviews
Description
Overview
| Activity | DPLVP |
|---|---|
| Range of product | ACTI9 |
| range of product | ECOSTRUXURE |
| Product or component type | SMART COMMUNICATION MODULE |
| Product name | ECOSTRUXURE I/O SMART LINK |
| Device short name | I/O Smart Link |
| Application type | LOAD CONTROLBREAKER STATUS MONITORINGBASIC ENERGY METERING E |
| Number max of connected devices | UP TO 11 WIRED DEVICES |
| Group of channels | 1 GROUP OF 11 DIGITAL CHANNELS |
| Maximum supply current | 1.5 A |
| [Us] rated supply voltage | 24 V DC +/- 20 % |
| Connectivity to devices | DIGITAL INPUT AND OUTPUTPULSE OUTPUT METER |
| Communication service | MODBUS SERVER FOR RS485 |
| Web server | BMS CONTROLLER COMPATIBLE |
| Application specific I/O | PULSE TOTALISING COUNTERPULSE CONVERTER |
| Protection type | AGAINST REVERSE POLARITY FOR AUXILIARY SUPPLYAGAINST REVERSE POLARITY FOR INPUTOVERVOLTAGE AT 33 V DC FOR DIGITAL OUTPUT |
| Immunity to microbreaks | 10 MS |
| Reset | FACTORY RESET ON FRONT FACEBY BOOTED PUSH-BUTTONBY ADDRESS ENCODERBY PLUG IN, PLUG OUT THE POWER SUPPLY |
| Input/output type | 2 INPUTS + 1 OUTPUT PER DIGITAL CHANNEL |
| Input type | CURRENT SINK FOR DIGITAL INPUT, 24 V DC +/- 20 % AT 2.5 MA |
| Maximum permanent current | 5 MA FOR DIGITAL INPUT |
| Electronic filtering time | 2 MS FOR DIGITAL INPUT FROM STATE 0 TO STATE 1 |
| Output type | LOGIC CURRENT SOURCE: 24 V - DC - 100 MA |
| Inrush current | 0.5 A FOR DIGITAL OUTPUT7 A FOR POWER SUPPLY |
| Local signalling | COMMUNICATION: 1 LED (YELLOW)STATUS: 1 LED (GREEN, ORANGE AND RED) |
| Type of setting | MODBUS ADDRESS 01...99 FOR ADDRESS ENCODERSRESET FOR ADDRESS ENCODERSRESET FOR PLUG IN, PLUG OUT THE AUXILIARY SUPPLY |
| Mounting position | HORIZONTAL AND VERTICAL ON DIN RAIL |
| Colour | WHITE (RAL 9003) |
| Location of connection | FRONT |
| Connections - terminals | SPRING-LOADED TERMINAL TI24 QTY: 11 FOR DIGITAL INPUT/OUTPUT, ORDERED SEPARATELYPLUG-IN CONNECTOR QTY: 1 FOR SUPPLY CIRCUITPLUG-IN CONNECTOR QTY: 1 FOR COMMUNICATION BUS |
| Clamping connection capacity | 2 X 0.2...2 X 1.5 MM² FOR TWISTED SHIELDED PAIRS CABLE, FLEXIBLE WITH CABLE END FOR COMMUNICATION BUS2 X 0.2...2 X 1.5 MM² FOR TWISTED SHIELDED PAIRS CABLE, FLEXIBLE WITHOUT CABLE END FOR COMMUNICATION BUS2 X 0.2...2 X 1.5 MM² FOR TWISTED SHIELDED PAIRS CABLE, RIGID WITH CABLE END FOR COMMUNICATION BUS2 X 0.2...2 X 1.5 MM² FOR TWISTED SHIELDED PAIRS CABLE, RIGID WITHOUT CABLE END FOR COMMUNICATION BUS1 X 0.2...1 X 1.5 MM², FLEXIBLE WITH CABLE END FOR CONTROL1 X 0.2...1 X 1.5 MM², FLEXIBLE WITHOUT CABLE END FOR CONTROL1 X 0.2...1 X 1.5 MM², RIGID WITH CABLE END FOR CONTROL1 X 0.2...1 X 1.5 MM², RIGID WITHOUT CABLE END FOR CONTROL2 X 0.2...2 X 1.5 MM², FLEXIBLE WITH CABLE END FOR SUPPLY CIRCUIT2 X 0.2...2 X 1.5 MM², FLEXIBLE WITHOUT CABLE END FOR SUPPLY CIRCUIT2 X 0.2...2 X 1.5 MM², RIGID WITH CABLE END FOR SUPPLY CIRCUIT2 X 0.2...2 X 1.5 MM², RIGID WITHOUT CABLE END FOR SUPPLY CIRCUIT |
| Wire stripping length | CONTROL: 10 MMSUPPLY CIRCUIT: 7 MMCOMMUNICATION BUS: 7 MM |
| Communication network type | RS485 MODBUS RTU CLIENT/SERVER SUB-D 9 4800 BPS, 9600 BPS, 19200 BPS, 38.4 KBPS |
| 9 mm pitches | 0 USEFUL |
| Height | 22.5 MM |
| Width | 359 MM |
| Depth | 42 MM |
| Product weight | 188 G |
| Provided equipment | SET OF 1 BUS CONNECTORSET OF 1 POWER SUPPLY CONNECTORSET OF 2 LOCKING CLIPS |
| Range compatibility | ACTI 9 ITL AUXILIARYLINERGY LINERGY FMACTI 9 IOF+SD 24ACTI 9 IACT24ACTI 9 IATL24POWERLOGIC PULSE OUTPUT METERACTI 9 RCA IC60ACTI 9 ACTI9 ICT AUXILIARYACTI 9 ACTI9 IC60ACTI 9 ACTI9 IIDACTI 9 ACTI9 ISW-NAACTI 9 ACTI9 IDPN VIGIACTI 9 ACTI9 C40MULTI9 MULTI9 C60ACTI 9 ACTI9 DT40ACTI 9 ACTI9 DT60ACTI 9 ACTI9 I-NAACTI 9 ACTI9 ITG40ACTI 9 ACTI9 IDPNACTI 9 ACTI9 REFLEX IC60 TI24 CONNECTOR |
| Commissioning interface | ECOSTRUXURE POWER COMMISSION |
| Market segment | BUILDINGSSMALL COMMERCIAL |
| Compatibility code | ACTI 9 SMARTLINK |
| IP degree of protection | IP20 |
| IK degree of protection | IK06 CONFORMING TO IEC 62262 |
| Pollution degree | 3 |
| Electromagnetic compatibility | RESISTANCE TO ELECTROSTATIC DISCHARGE (AIR DISCHARGE), CLASS B, 8 KV, CONFORMING TO IEC 61000-4-2RESISTANCE TO ELECTROSTATIC DISCHARGE (CONTACT DISCHARGE), CLASS B, 4 KV, CONFORMING TO IEC 61000-4-2RESISTANCE TO RADIATED ELECTROMAGNETIC FIELDS (80 MHZ...3 GHZ), CLASS A, 10 V/M, CONFORMING TO IEC 61000-4-3POWER SUPPLY: RESISTANCE TO RADIATED ELECTROMAGNETIC FIELDS (1.4…6 GHZ), CLASS A, 3 V/M, CONFORMING TO IEC 61000-4-3POWER SUPPLY: RESISTANCE TO FAST TRANSIENT (5...100 KHZ), CLASS B, 2 KV, CONFORMING TO IEC 61000-4-4INPUT/OUTPUT: RESISTANCE TO FAST TRANSIENT, CLASS B, 1 KV, CONFORMING TO IEC 61000-4-4COMMUNICATION BUS: RESISTANCE TO FAST TRANSIENT (0.15...80 MHZ), CLASS B, 1 KV, CONFORMING TO IEC 61000-4-4CONDUCTED EMC (0.15...80 MHZ), CLASS A, 3 V, CONFORMING TO IEC 61000-4-6CONDUCTED EMISSION (0.15...30 MHZ), CLASS B, CONFORMING TO IEC 61326-1CONDUCTED EMISSION (0.15...30 MHZ), CLASS B, CONFORMING TO CISPR 11RADIATED EMISSION (30...6000 MHZ), CLASS B, CONFORMING TO IEC 61326-1RADIATED EMISSION (30...6000 MHZ), CLASS B, CONFORMING TO CISPR 11POWER SUPPLY: SURGES (DM COUPLING 42 OHM), CLASS B, 1 KV, CONFORMING TO IEC 61000-4-5POWER SUPPLY: SURGES (CM COUPLING 42 OHM), CLASS B, 2 KV, CONFORMING TO IEC 61000-4-5COMMUNICATION BUS: SURGES (CM COUPLING 2 OHM), CLASS B, 1 KV, CONFORMING TO IEC 61000-4-5 |
| Environmental characteristic | CORROSIVE 3C2 CONFORMING TO IEC 60721-3-3SALT MIST 2 CONFORMING TO IEC 60068-2-52 |
| Vibration resistance | 1 GN, AMPLITUDE = 3.5 MM (F = 5…300 HZ)10 CYCLES CONFORMING TO EN/IEC 60068-2-6 |
| Shock resistance | 15 GN FOR 11 MS CONFORMING TO IEC 60068-2-27 |
| Fire resistance | OTHER PARTS: 650 °C ( 30 S ) CONFORMING TO IEC 60695-2-10ON CONNECTION TERMINALS: 960 °C ( 30 S ) CONFORMING TO IEC 60695-2-10 |
| Tropicalisation | 2 |
| Relative humidity | 0…93 % AT 40 °C |
| Operating altitude | 0...2000 M |
| Ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Standards | IEC 61010-2-201IEC 61010-1 |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.300 CM |
| Package 1 Width | 6.500 CM |
| Package 1 Length | 37.000 CM |
| Package 1 Weight | 242.000 G |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 32 |
| Package 2 Height | 30.000 CM |
| Package 2 Width | 30.000 CM |
| Package 2 Length | 40.000 CM |
| Package 2 Weight | 8.200 KG |
| Warranty (in months) | 18 |
Environmental data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
| Sustainability | Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products. Guide to assessing product sustainability is a white paper that clarifies global eco-label standards and how to interpret environmental declarations. |
|---|---|
| Sustainable packaging | ✓ |
| Take-back | No |
| Mercury free | ✓ |
| Environmental Disclosure | Product Environmental Profile (Download) |
| End of life manual availability | End of Life Information (Download) |
| Total lifecycle Carbon footprint | 35 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 23.5061282635052 |
| Carbon footprint of the manufacturing phase [A1 to A3] | 24 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.6059365135946421 |
| Carbon footprint of the distribution phase [A4] | 0.6 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.001838859801891558 |
| Carbon footprint of the installation phase [A5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 9.927592750156709 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 10 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.6144217354690374 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.6 kg CO2 eq. |
| SCIP Number | 2c4a7f95-9fbf-4b2e-bc7e-82ceeb851894 |
| REACh Regulation | Reference contains Substances of Very High Concern above the threshold (Download) |
| EU RoHS Directive | Compliant By Exemption (Download) |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |