Acti9 iID - Residual Current Circuit Breaker - 4P - 40A - 300mA - B-SI type

A9Z64440
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Description

How to Video

Product Details

Activity HDCFD
Pincode Group default
Part Number A9Z64440
[Uimp] rated impulse withstand voltage 6 kV
9 Mm Pitches 8
Comb Busbar and Distribution Block Compatibility top or bottom: tooth
Connection Pitch 18 mm
Contact Position Indicator yes
Device Location in System outgoer, group incomer
Earth-leakage Protection Class type B-SI (Super Immunised)
Earth-leakage Protection Time Delay instantaneous
Earth-leakage Sensitivity 300 mA
Locking Options Description padlocking device
Neutral Position left
overvoltage category IV
Rated Breaking and Making Capacity Idm 1500 A, Im 1500 A
Rated Conditional Short-circuit Current 10 kA
Residual Current Tripping Technology voltage independent
ambient air temperature for storage -40-85 °C
colour white
connections - terminals double terminal front 1-35 mm² rigid, double terminal front 1-25 mm² flexible, double terminal front 1-25 mm² flexible with ferrule, double terminal back 1-25 mm² rigid, double terminal back 1-16 mm² flexible, double terminal back 1-16 mm² flexible with ferrule
control type toggle
depth 79 mm
device application photovoltaic, 3P speed drive, lift
device short name iID
Electrical Durability 15000 cycles
height 88 mm
IK degree of protection IK05
IP degree of protection IP20 conforming to IEC 60529, IP40 (modular enclosure) conforming to IEC 60529
mechanical durability 20000 cycles
mounting mode clip-on
mounting support DIN rail
net weight 415 g
network frequency 50 Hz
network type AC
operating altitude 0...2000 m
Poles Description 4P
pollution degree 3
product certifications CCC, KC
product or component type residual current circuit breaker (RCCB)
Quality Labels VDE, NF, IMQ, KEMA
range Acti9
width 72 mm
Wire Stripping Length 14 mm for top or bottom connection
ambient air temperature for operation -25-60 °C
standards IEC 61008-2-1, IEC/EN 62423, EN 61008-2-1
electromagnetic compatibility 8/20 µs impulse withstand, 3 kA conforming to EN/IEC 61008-1
local signalling ON/OFF indication, LED (green) for presence of voltage, trip indicator
[Ui] rated insulation voltage 500 V
tightening torque 3.5-3.5 N.m top or bottom

Seller Information

Documents

Reviews

Write Your Own Review
You're reviewing: Acti9 iID - Residual Current Circuit Breaker - 4P - 40A - 300mA - B-SI type
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.

Frequently Bought Together

Acti 9 -Auxiliary fault contact iSD - 1 C/O - AC/DC
A9A26927

In stock

AED 58.00
AED 87.05
voltage release - iMX - tripping unit - 110..415 VAC
A9A26476

In stock

AED 54.16
AED 185.63
voltage release - iMN - tripping unit - 220..240 VAC
A9A26960

In stock

AED 78.26
AED 268.20
voltage release - iMX - tripping unit - 12..24 VAC
A9A26478

In stock

AED 227.00
AED 340.06
voltage release - iMX+OF - tripping unit - 220..415 VAC
A9A26946

In stock

AED 152.00
AED 227.87
Acti 9 - Auxiliary contact iOF - 1 C/O - AC/DC
A9A26924

In stock

AED 57.00
AED 85.58
Acti 9 - Auxiliary contact iOF/SD+OF - 2OC - AC/DC
A9A26929

In stock

AED 48.00
AED 71.20
padlocking device - 18 mm
A9A26970

In stock

AED 158.00
AED 235.94